115 resultados para laser driver
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The purpose of this study was to investigate the histological changes that occur in rat soft and hard tissues after Er,Cr:YSGG laser surgery. Each of 20 rats was submitted to four procedures which were randomly distributed to the right and left sides of the animal: procedure 1 dorsal incision with a scalpel; procedure 2 dorsal incision with a 2.0-W Er,Cr:YSGG laser; procedure 3 skull defect created with a diamond bur; procedure 4 skull defect created with a 3.0-W Er,Cr:YSGG laser. The animals were killed 3, 7, 15 and 30 days after surgery, and histological examinations were performed. The histometric analysis of the bone defects was evaluated using an unpaired t-test. Initially, the dorsum showed more histological signs of repair following procedure 1, although similar healing responses following procedures 1 and 2 were seen on day 30 after surgery. By day 30 the bone formation observed following procedure 4 was much more evident than following procedure 3. The unpaired t-test identified significant differences in bone formation on day 30 (p = 0.01), whereas a greater bone percentage was seen following procedure 4 than following procedure 3 (79.96 +/- 10.30% and 58.23 +/- 9.99%, respectively). Thus, histological repair of the Er,Cr:YSGG laser wounds was similar to that of the scalpel wounds. However, skull defects created with the Er,Cr:YSGG laser showed greater bone formation than defects created with the bur. Within the limitations of this study, we can conclude that the Er,Cr:YSGG laser is a promising surgical instrument in vivo, particularly for bone surgery.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this in vivo study was to evaluate the thermal effects caused by 810 nm 1.2 W diode laser irradiation of periodontal tissues. Despite all data available concerning the laser application for periodontal treatment, one of the most relevant challenges is to prevent the harmful tissue heating induced by different clinical protocols. Periodontal pockets were induced at molars in 96 rats. Several irradiation powers under CW mode were investigated: 0, 400, 600, 800, 1000, 1200 mW. The pockets were irradiated using a 300 A mu m frontal illumination fiber. The animals were killed at 4 or 10 days after irradiation. The mandible was surgically removed and histologically processed. The histological sections stained with H/E demonstrated that irradiation parameters up to 1000 mW were thermally safe for the periodontal tissues. The sections stained with Brown & Brenn technique evidenced bacteria in the periodontal tissues. Consequently, the diode laser irradiation as a unique treatment was not capable to eliminate bacteria of the biofilm present in the pockets. According to the methodology used here, it was concluded that the thermal variation promoted by a diode laser can cause damage to periodontal tissues depending on the energy density used. The 1.2 W diode laser irradiation itself does not control the bacteria present in the biofilm of the periodontal pockets without mechanical action. The knowledge of proper high intensity laser parameters and methods of irradiation for periodontal protocols may prevent any undesirable thermal damage to the tissues.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study investigated the effects of 670 nm laser, at different fluences, on the viability of skin flap in rats. One hundred male animals were used. The animals were divided into control group; group treated with 3 J/cm(2); group treated with 6 J/cm(2); group treated with 12 J/cm(2) and group treated with 24 J/cm(2). The skin flap was made on the backs of all animals studied, with a plastic sheet interposed between the flap and the donor site. Laser irradiation was done immediately after the surgery and on days 1, 2, 3 and 4 after surgery. The percentage of necrosis of the flap was calculated at the 7th postoperative day. Additionally, a sample of each flap was collected to enable us to count the blood vessels. Treated animals showed a statistically significant smaller area of necrosis than did the control group. The necrosis in the treated groups was 41.82% (group 2), 36.51% (group 3), 29.45% (group 4) and 20.37% (group 5). We also demonstrated that laser irradiation at 670 nm, at all doses used, had a stimulatory effect on angiogenesis. Our study showed that the 670 nm laser was efficient to increase the viability of the skin flap, at all fluences used, with a tendency of reaching better results at higher doses.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Low-level laser therapy (LLLT) accelerates tissue repair. Mast cells induce the proliferation of fibroblasts and the development of local fibrosis. The objective of this study was to quantify fibrosis rate and mast cells in connective tissue after endodontic sealer zinc oxide and eugenol (ZOE) was implanted and submitted to LLLT, immediately after implant and again 24 h later. Sixty mice were distributed into three groups: GI, GII, and GIII (n = 20). In GI, the tubes filled with Endofill were implanted in the animals and were not irradiated with LLLT. In GII, the tubes containing Endofill were implanted in the animals and then irradiated with red LLLT (InGaAIP) 685-nm wavelength, D=72 J/Cm(2), E = 2 J, T=58 s, P=35 mW, and in GIII, the tubes with Endofill were implanted and irradiated with infrared LLLT (AsGaAl) 830-nm wavelength, D=70 J/Cm(2), E = 2 J, T=40 s, P=50 mW. After 7 days and 30 days, the animals were killed. A series of 6-mu m-thick sections were obtained and stained with Toluidine Blue and Picrosirius and analyzed under a standard light microscope using a polarized light filter for the quantification of fibrosis. The statistics were qualitative and quantitative with a significance of 5%. The irradiation with LLLT did not offer improvement in the fibrosis rate, however, it provided a significant decrease in the concentration of independent mast cells for the period studied.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to evaluate in vivo the use of low-level galium-aluminium-arsenide (GaAlAs) (BDP 600) laser and sodium fluoride varnish (Duraphat((R))) in the treatment of cervical dentine hypersensitivity. Twelve patients, with at least two sensitive teeth were selected. A total of 60 teeth were included in the trial. Prior to desensitizing treatment, dentine hypersensitivity was assessed by a thermal stimulus and patients' response to the examination was considered to be a control. The GaAlAs laser (15 mW, 4 J/cm(2)) was irradiated on contact mode and fluoride varnish was applied at cervical region. The efficiency of the treatments was assessed at three examination periods: immediately after first application, 15 and 30 days after the first application. The degree of sensitivity was determined following predefined criteria. Data were submitted to analysis and no statistically significant difference was observed between fluoride varnish and laser. Considering the treatments separately, there was no significant difference for the fluoride varnish at the three examination periods, and for laser therapy, significant difference (P < 0.05) was found solely between the values obtained before the treatment and 30 days after the first application. It may be concluded that both treatments may be effective in decreasing cervical dentinal hypersensitivity. Moreover, the low-level GaAlAs laser showed improved results for treating teeth with higher degree of sensitivity.
Resumo:
Background and Objective: evaluate the adhesion of adhesive restorations with and without a base of resin-modified glass-ionomer cement (RMGIC) to dentin irradiated with Er:YAG laser.Study Design/Materials and Methods: Twenty-four human molar teeth were divided into 6 groups (n=4): G1) 37% Phosphoric acid (PA) + Adhesive system (Ad) + Composite resin (CR); G2) RMGIC + CR; G3) Laser (60mJ-5Hz-20s) + PA + Ad + CR; G4) Laser (60 mJ-5 Hz-20 s) + RMGIC + CR; G5) Laser (100mJ-5Hz-20s) + PA + Ad + CR; G6) Laser (100mJ-5Hz-20s) + RMGIC + CR. Teeth were prepared, restored and cut into specimens, according to the treatment proposed and to methodology for microtensile test. Data were submitted to ANOVA and Tukey statistical tests (alpha=5%).Results:. The mean values for adhesion (MPa) and standard deviation (+/- SD) were: G1) 26.30(+/- 4.50), G2) 5.34(+/- 2.87), G3) 21.16(+/- 6.01), G4) 5.22(+/- 1.52), G5) 22.23(+/- 4.98), G6) 5.25(+/- 3.08).Conclusion: the use of Er:YAG laser did not influence on the restorations adhesion.