55 resultados para gradient chamber
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study was developed to evaluate the performance of different coagulant and pH dosages by applying the use of Dissolved Air Flotation (FAD) to enable its use in effluent treatment of the extraction process of palm oil. The study was developed in the laboratory, where studies about emulsions stability were made for the production of a synthetic effluent which best suit the characteristics of raw effluent. The synthetic water that would be used in the tests of FAD was produced, once the stability and characterization which best approached the raw wastewater was obtained. Trials tested three coagulant doses, combined with various pH ranges and five upward velocities (Va), finding an optimal range of this combination. Some operating parameters such as time and gradient of rapid mixing (20 s / 1000 s-1), time and gradient flotation (15 min / 60 s-1), chamber pressure saturation (450 kPa) and recirculation rate (20%) were set. In this way, samples were collected for analysis of the removal of turbidity parameters, suspended solids and oils and greases. This one is obtained by a correlation turbidity x oils and greases, referring to the previous analysis. The degree of removal obtained were 73,97% for turbidity, 51,4% for total suspended solids and 86,2% for oils and greases. Removal rates may be increased in later studies, by ranging the velocity gradient and flocculation parameters and the recirculation ratio, and by using lower flotation speeds to these effluent characteristics.
Resumo:
Stem cells are defined as cells capable of self-renewal and differentiation into specialized cells when submited to external signalings in the enviroment. Among adult stem cells, mesenchymal cells occupy an important position because they can differentiate into mesodermal cells such as osteoblasts, adipocytes and chondrocytes. Cell therapy consists in the use of mesenchymal stem cells (MSC) in the treatment of degenerative diseases and harmed tissue reconstruction. Due to the longstanding and costly procedure for cultivation of MSC, it was proposed the use of low power light sources, such as light emitting diodes (LED), to optimize these factors. Recent works have shown a series of results from the influence of LED light on biological tissues such as increased rate of cell proliferation, increased RNA, DNA and ATP synthesis rate. The purpose of this study is to compare the biomodulator effect of LED light set at wavelengths 630nm ± 10nm and 805nm ± 10nm on the mesenchymal stem cells proliferation. For this, the mesenchymal stem cells culture adopted the procedure used in the Departament of Animal Reproduction and Veterinary Radiology of the Faculty of Veterinary Medicine and Animal Sciences of Botucatu. MSC were obtained from an adult horse bone marrow, and isolated by density gradient separation, with the FICOLL reagent and by centrifugation. The pellet containing the stem cells was removed and these were placed in low glucose DMEM culture medium, containing 10% fetal calf serum and antibiotics. The material was observed daily by inverted microscopy for monitoring the progression of the cells and subsequently the amount of cells were counted in a Neubauer counting chamber. The amount of MSC was obtained by cell culture seeded in 24 wells culture plate and segregated into three distinct groups: Group 1 was irradiated with wavelength set at 630nm ± 10 nm, Group... (Complete abstract click electronic access below)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In general, the studies of finite size effects in mesoscopic superconductors have been carried out in such a way that the temperature parameter is constant in the entire system. However, we could have situations where a real sample is near a heater source, as an example. In such situations, gradients of temperature are present. On the other hand, mesoscopic superconductors are interesting systems due to the fact that they present confinement effects which influence all the vortex dynamics. Thus, in this work we studied the influence of thermal gradients on the vortex dynamics in mesoscopic superconductors. For this purposes, we used the time dependent Ginzburg-Landau equations. The thermal gradients produce an asymmetric distribution of the currents around the system which, in turn, yield interesting vortex configurations and difficult the formation of giant vortices.
Resumo:
This aim of the present study was to evaluate the pulp chamber penetration of 35% hydrogen peroxide activated by LED (light-emitting diode) or Nd:YAG laser in bovine teeth, after an in-office bleaching technique. Forty-eight bovine lateral incisors were divided into four groups, acetate buffer was placed into the pulp chamber and bleaching agent was applied as follows: for group A (n = 12), activation was performed by LED; for group B (n = 12), activation was performed by Nd:YAG laser (60 mJ, 20 Hz); group C (n = 12) received no light or laser activation; and the control group (n = 12) received no bleaching gel application or light or laser activation. The acetate buffer solution was transferred to a glass tube and Leuco Crystal Violet and horseradish peroxidase were added, producing a blue solution. The optical density of this solution was determined spectrophotometrically and converted into microgram equivalents of hydrogen peroxide. The results were analysed using ANOVA and Tukey's test (5%). It was verified that the effect of activation was significant, as groups activated by LED or laser presented greater hydrogen peroxide penetration into the pulp chamber (0.499 +/- 0.622 microg) compared with groups that were not (0.198 +/- 0.218 microg). There was no statistically significant difference in the penetration of hydrogen peroxide into the pulp chamber between the two types of activation (LED or laser). The results suggest that activation by laser or LED caused an increase in hydrogen peroxide penetration into the pulp chamber.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)