59 resultados para fluid flow control


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To investigate the ability of BioRoot RCS, a tricalcium silicate-based root canal sealer and AH Plus to effectively fill the root canals of contralateral teeth using three evaluation methods, and to investigate also the correlation between the methods. The prepared root canals of ten pairs of contralateral mandibular premolar teeth were filled with gutta-percha and sealer using lateral compaction. The percentage of voids within the root canal was assessed by micro-computed tomography, whilst sealing ability was investigated by fluid transport and leakage of fluorescent microspheres. The interaction of sealer with dentine, and sealer penetration were assessed by confocal microscopy. The void volume, fluid flow, microsphere leakage and sealer interaction with dentine for both materials were compared. Nonparametric (Mann-Whitney) tests were used to compare the % void and fluid transport of the two sealers. Spearman correlation was used to assess the pairwise relationships between the techniques. The level of significance was set to 0.05. BioRoot RCS exhibited significantly more percentage of voids than AH Plus. There was no difference in fluid flow and microsphere penetration. BioRoot RCS exhibited a different pattern of sealer penetration and interaction with the dentine walls compared to AH Plus. For both materials, the pairwise correlations between the three techniques were close to zero, indicating weak relationships. MicroCT analysis revealed a higher void volume for BioRoot RCS. The other techniques did not show a difference between the sealing ability of the sealers. The correlation between the three ex vivo methods of assessment was weak demonstrating their complementarity rather than their concordance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the currently strict environmental law in present days, researchers and industries are seeking to reduce the amount of cutting fluid used in machining. Minimum quantity lubrication is a potential alternative to reduce environmental impacts and overall process costs. This technique can substantially reduce cutting fluids in grinding, as well as provide better performance in relation to conventional cutting fluid application (abundant fluid flow). The present work aims to test the viability of minimum quantity lubrication (with and without water) in grinding of advanced ceramics, when compared to conventional method (abundant fluid flow). Measured output variables were grinding power, surface roughness, roundness errors and wheel wear, as well as scanning electron micrographs. The results show that minimum quantity lubrication with water (1:1) was superior to conventional lubrication-cooling in terms of surface quality, also reducing wheel wear, when compared to the other methods tested.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The application of pesticides is one of the most important steps in the agricultural production process. The spray volume can directly affect application success, and this parameter is directly dependent on the displacement speed of the sprayer. In conventional systems, the operator has to maintain a constant speed to ensure uniform application along the tracks. In order to improve over application quality and preserve levels of precision for applied doses; the use of electronic flow control systems allows for automatic adjustment of volume applied over the area when there is a change in velocity during application. The objective of this research was to study the response times of a flow controller with DGPS for aerial application subjected to variations of velocity in laboratory simulated flight conditions. For this purpose, a bench test has been developed including software for simulating DGPS signals, which was used to simulate different flight speeds and conditions. The results showed the average response time from the flow controller to a change in velocity to be between 6 and 20 seconds. Variations in total flow and the controller setting had a significant influence on response time with situations where there was interaction between the factors being evaluated. There was a tendency for better response times using a constant setting for the control algorithm other than that specified by the manufacturer. The flow controller presented an average error rates below 2% in all evaluated operating conditions, providing satisfactory accuracy in determining the output of product in different test situations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Intermittent hemodialysis (IHD) and continuous renal replacement therapies (CRRT) are used as Acute Kidney Injury (AKI) therapy and have certain advantages and disadvantages. Extended daily dialysis (EDD) has emerged as an alternative to CRRT in the management of hemodynamically unstable AKI patients, mainly in developed countries.Objectives: We hypothesized that EDD is a safe option for AKI treatment and aimed to describe metabolic and fluid control of AKI patients undergoing EDD and identify complications and risk factors associated with death.Study Selection: This is an observational and retrospective study describing introduction of EDD at our institution. A total of 231 hemodynamically unstable AKI patients (noradrenalin dose between 0.3 and 1.0 ucg/kg/min) were assigned to 1367 EDD session. EDD consisted of 6-8 h of HD 6 days a week, with blood flow of 200 ml/min, dialysate flows of 300 ml/min.Data Synthesis: Mean age was 60.6 +/- 15.8 years, 97.4% of patients were in the intensive care unit, and sepsis was the main etiology of AKI (76.2). BUN and creatinine levels stabilized after four sessions at around 38 and 2.4 mg/dl, respectively. Fluid balance decreased progressively and stabilized around zero after five sessions. Weekly delivered Kt/V was 5.94 +/- 0.7. Hypotension and filter clotting occurred in 47.5 and 12.4% of treatment session, respectively. Regarding AKI outcome, 22.5% of patients presented renal function recovery, 5.6% of patients remained on dialysis after 30 days, and 71.9% of patients died. Age and focus abdominal sepsis were identified as risk factors for death. Urine output and negative fluid balance were identified as protective factors.Conclusions: EDD is effective for AKI patients, allowing adequate metabolic and fluid control. Age, focus abdominal sepsis, and lower urine output as well as positive fluid balance after two EDD sessions were associated significantly with death.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Free surface flows in inclined channels can develop periodic instabilities that are propagated downstream as shock waves with well-defined wavelengths and amplitudes. Such disturbances are called roll waves and are common in channels, torrential lava, landslides, and avalanches. The prediction and detection of such waves over certain types of structures and environments are useful for the prevention of natural risks. In this work, a mathematical model is established using a theoretical approach based on Cauchy's equations with the Herschel-Bulkley rheological model inserted into the viscous part of the stress tensor. This arrangement can adequately represent the behavior of muddy fluids, such as water-clay mixture. Then, taking into account the shallow water and the Rankine-Hugoniot's (shock wave) conditions, the equation of the roll wave and its properties, profile, and propagation velocity are determined. A linear stability analysis is performed with an emphasis on determining the condition that allows the generation of such instabilities, which depends on the minimum Froude number. A sensitivity analysis on the numerical parameters is performed, and numerical results including the influence of the Froude number, the index flow and dimensionless yield stress on the amplitude, the wavelength of roll waves and the propagation velocity of roll waves are shown. We show that our numerical results were in agreement with Coussot's experimental results (1994).