250 resultados para evaristo de moraes filho


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare the reaction of rat subcutaneous connective tissue to 0.9% sterile saline, 2.5% sodium hypochlorite (NaOCl), 5.25% NaOCl and 2% chlorhexidine gluconate solution or gel. Six circles were demarcated on the dorsal skin of 24 male Wistar rats, leaving 2 cm between each circle. Using a syringe, 0.1 mL of each root canal irrigant was injected subcutaneously into 5 circles. In the 6th circle, the needle of an empty syringe was introduced into the skin, but no irrigant was injected (control group). Evaluations were undertaken at 2 h, 48 h, 14 days and 30 days post-procedure. Tissue samples were excised, embedded in paraffin blocks and 3-mu m-thick sections were obtained and stained with hematoxylin and eosin. The areas of inflammatory reaction were evaluated and analyzed statistically by ANOVA and Tukey's test. The control group showed few or no inflammatory reaction areas in the subcutaneous tissue. 0.9% saline solution, 2.0% chlorhexidine solution and 2.5% NaOCl showed a good biocompatibility, as very mild inflammatory reaction was detected at 14 days and tissue repair occurred at 30 days. 5.25% NaOCl was the most toxic irrigant, as the number of inflammatory cells remained elevated at 14 and 30 days. The group treated with 2.0% chlorhexidine gluconate gel presented a moderate inflammatory response at 14 days, which decreased at 30 days, being considered similar to that of the control group, 0.9% saline solution, 2.0% chlorhexidine solution and 2.5% NaOCl at this experimental period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to histopathologically examine the reaction of the connective tissue of rats to 2 calcium hydroxide-based sealers, Acroseal and Sealapex. Dentin tubes containing the materials and empty control tubes were implanted into the dorsal connective tissue of 36 Wistar albino rats. The animals were killed after 7 or 30 days, and the specimens were prepared for histologic analysis with hematoxylin and eosin, Von Kossa technique, and polarized light. Results were statistically analyzed using Kruskal-Wallis test. Both materials caused mild or moderate inflammatory reactions on the 7th day, but these reactions decreased by the 30th day with no significant difference at any time (P > .05). Mineralization of the subcutaneous tissue of the rats was observed only with Sealapex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the rat subcutaneous tissue response to implanted polyethylene tubes filled with Endo-CPM-Sealer (Portland Cement Modified Sealer) (EGEO S.R.L., Buenos Aires, Argentina) compared with Sealapex (SybronEndo, Glendora, CA) and Angelus MTA (Angelus, Londrina, Brazil). These materials were placed in polyethylene and dentin tubes and implanted into dorsal connective tissue of Wistar rats for 7, 15, 30, 60, and 90 days. The specimens were prepared to be stained with hematoxylin and eosin or Von Kossa or not stained for polarized light. Qualitative and quantitative evaluations of the reaction were performed. Both materials caused mild to moderate reactions at 7 days that decreased with time. The response was similar to the control on the 30th day with Endo-CPM-Sealer and Angelus MTA and on the 60th day with Sealapex. Mineralization and granulations birefringent to the polarized light were observed with all materials. it was possible to conclude that Endo-CPM-Sealer was biocompatible and stimulated mineralization. (J Endod 2009;35:256-260)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the pH, calcium release, setting time, and solubility of two commercially available mineral trioxide aggregate (MTA) cements (white MTA Angelus and MTA Bio), and of three experimental cements (light-cured MTA, Portland cement with 20% bismuth oxide and 5% calcium sulfate, and an epoxy resin-based cement).Study design. For evaluation of pH and calcium ion release, polyethylene tubes with 1.0 mm internal diameter and 10.0 mm length were filled with the cements and immediately immersed in flasks containing 10 mL deionized water. After 3, 24, 72, and 168 hours, the tubes were removed and the water from the previous container was measured for its pH and calcium content with a pH meter and an atomic absorption spectrophotometer. For analysis of the setting time, Gilmore needles weighing 100 g and 456.5 g were used, in accordance with the American Society for Testing and Materials specification no. C266-03. Solubility of each cement was also tested.Results. All the cements were alkaline and released calcium ions, with a declining trend over time. After 3 hours, Portland cement + bismuth oxide and MTA Bio had the highest pH and light-cured MTA the lowest. After 1 week, MTA Bio had the highest pH and light-cured MTA and epoxy resin-based cement the lowest. Regarding calcium ion release, after 3 hours, Portland cement + bismuth oxide showed the highest release. After 1 week, MTA Bio had the highest. Epoxy resin-based cement and light-cured MTA had the lowest calcium release in all evaluation periods. Regarding setting times, white MTA Angelus and MTA Bio had the shortest, Portland cement + bismuth oxide had an intermediate setting time, and the epoxy resin-based cement had the longest. The materials that showed the lowest solubility values were the epoxy resin-based cement, Portland cement + bismuth oxide, and light-cured MTA. The highest solubility values were presented in white MTA Angelus and MTA Bio.Conclusions. The white MTA Angelus and MTA Bio had the shortest setting times, higher pH and calcium ion release, and the highest solubility. In contrast, the epoxy resin-based cement and light-cured MTA showed lower values of solubility, pH, and calcium ion release. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 250-256)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Root resorption can cause damage in orthodontic patients. Digital subtraction radiography (DSR) is a useful resource for the detection of mineral losses. The purpose of this study was to compare the efficacy of digital radiography (DR) and DSR in detecting simulated external root resorption. Examiner agreement between the 2 techniques was also evaluated. Methods: Root resorptions of various sizes were simulated on the apical and lingual aspects of 49 teeth from 9 dry human mandibles. The teeth were radiographed in standardized conditions. The radiographs were registered with Regeemy Image Registration and Mosaicking (version 0.2.43-RCB, DPI-INPE, Sao Jose dos Campos, São Paulo, Brazil) and subtracted with Image Tool (University of Texas Health Science Center at San Antonio). The subtracted images and the digital radiographs were evaluated by 3 oral radiologists. Results: No statistically significant differences were found for the methods in the detection of apical root resorptions, independently from lesion size, and of lingual resorptions of 1.2 mm or greater. DSR was significantly better than DR for detection of lingual resorptions up to 1 mm. Resorptions less than 0.5 mm were not precisely detected by either method. DSR provided better intraexaminer and interexaminer agreement than did DR. Conclusions: Both methods are precise for detection of apical root resorptions as small as 0.5 mm and lingual resorptions of 1 mm or more. However, DSR frequently performed better than did DR. (Am J Orthod Dentofacial Orthop 2011;139:324-33)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)