108 resultados para electron microscopy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the course of an investigation on lizard spermiogenesis, the authors have observed events connected with the differentiation of the acrosome and middle-piece of the spermatozoa. Some differences from other reptilians were found as well as: the presence of a subacrosomal space, the absence of the fibrous sheath in the middle-piece, and a very short neck in the mature spermatozoa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cytogenetic studies conduced on a sample of 19 specimens of rainbow trout (Oncorhyncus mykiss) showed that 6 presented two chromosomes with a single subterminal AgNOR on the short arms and 13 presented one chromosome with a single subterminal Ag-NOR and a second chromosome with two small subterminal Ag-NORs. Synaptonemal complex studies showed the presence of a pairing failure involving the two lateral elements (LEs) of the NOR-bearing chromosomes only in those specimens with two different NOR-bearing chromosomes, suggesting that the chromosomes with two Ag-NORs originated from a paracentric inversion involving a terminal segment of the original NOR-bearing chromosome. A comparative analysis between three normal and three heterozygous fishes suggest that in the latter group the LEs of the NOR-bearing chromosomes initiate the synaptic process in a more delayed manner, the synapsis develops more quickly, and the nucleolus stays associated with chromosomes for a longer time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The articular disc of the temporomandibular joint was studied in fetuses (16 to 39 weeks of intrauterine life), infants (up to 4 months of age), dentulous adults (aged 30 to 39 years), and completely edentulous adults (aged 60 to 69 years) by scanning electron microscopy. The constituent bundles of collagen fibers were stratified and were oriented anteroposteriorly, laterolaterally, and obliquely in the middle portion of the disc. A ring of laterolateral bundles constituted the main feature of the thick posterior portion. In the anterior portion of the disc, the fibers were anteroposteriorly and obliquely oriented. On the superior and inferior surfaces of the disc, a thin layer of perpendicularly arranged collagen fibers covered the underlying, thick, laterolateral oriented collagen fibers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Morphological features of the mid-palatal suture were studied in human foetuses from 4 to 9 months of intra-uterine life. The foetuses were divided into three age groups, GI (16-23 weeks), GII (24-31 weeks) and GIII (32-39 weeks). The mid-palatal suture in GI foetuses is rectilineal in form with a wide space between the palatal processes of the maxilla. The suture has a sinuous nature in GII and GIII foetuses due to growth of the bone processes crossing the mid-line. A wide zone of cellular proliferation observed in GI narrows in GII and GIII foetuses. The imbricating nature of the suture in GII and GIII is caused by bone growth adjacent to the mid-palatal suture. Sharpey's fibres, emerging from the bone processes, run to the median region of the mid-palatal suture and are observed from GI foetuses onwards. The collagen fibres of the mid-palatal suture are orientated transversely under the oral epithelium and exhibit a regular meshwork with a predominance of sagittal fibres in the median region of the suture. These fibres are orientated transversely and obliquely at the junction with the nasal septum.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Silicon crystal exhibits a ductile regime during machining prior to the onset of fracture when appropriate cutting conditions are applied. The present study shows that the ductile regime is a result of a phase transformation which is indirectly evidenced by the amorphous phase detected in the machined surface. Transmission electron microscopy (TEM) planar view studies were successfully performed on monocrystalline silicon (1 0 0) single point diamond turned. TEM electron diffraction patterns show that the machined surface presents diffuse rings along with traces of crystalline material. This is attributed to crystalline silicon immersed in an amorphous matrix. Furthermore, only diffuse rings in the diffraction patterns of the ductile chip are detected, indicating that it is totally amorphous. © 2000 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cells of the choroid plexus of the lateral ventricles of the monkey Cebus apella apella were examined through scanning electron microscopy at contributing to the description of such structures in primates. The animals were anesthetized previously with 3% hypnol intraperitoneally and after perfusion with 2.5% glutaraldehyde, samples of the choroid plexus were collected after exhibition of the central portion and inferior horn of the lateral ventricles. The ventricular surface of those cells presents globose form as well as fine interlaced protrusions named microvilli. Among those, it is observed the presence of some cilia. Resting on the choroid epithelial cells there is a variable number of free cells, with fine prolongations which extend from them. They are probably macrophages and have been compared to Kolmer cells or epiplexus cells, located on choroid epithelium. The choroid plexus of the encephalic lateral ventricles of the monkey Cebus apella apella at scanning electron microscopy is similar to that of other primates, as well as to that of other species of mammals mainly cats and rats, and also humans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The corneal endothelium is essential for the maintenance of the corneal transparency. The aim of this study was to examine the morphology of the endothelial surface and perform morphometric analysis of the normal corneal endothelial cells of the Magellanic penguin (Spheniscus magellanicus) using scanning electron microscopy. The present work demonstrates that the corneal endothelium of the Magellanic penguin is similar to those described in other vertebrates. Copyright 2005 by American Association of Zoo Veterinarians.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acid etching promotes microporosities on enamel surface, which provide a better bonding surface to adhesive materials. The purpose of this study was to comparatively analyze the microstructure of enamel surface after etching with 37% phosphoric acid or with two self-etching primers, Non-rinse conditioner (NRC) and Clearfil SE Bond (CSEB) using scanning electron microscopy. Thirty sound premolars were divided into 3 groups with ten teeth each: Group 1: the buccal surface was etched with 37% phosphoric acid for 15 seconds; Group 2: the buccal surface was etched with NRC for 20 seconds; Group 3: the buccal surface was etched with CSEB for 20 seconds. Teeth from Group 1 were rinsed with water; teeth from all groups were air-dried for 15 seconds. After that, all specimens were processed for scanning electron microscopy and analyzed in a Jeol 6100 SEM. The results showed deeper etching when the enamel surface was etched with 37% phosphoric acid, followed by NRC and CSEB. It is concluded that 37% phosphoric acid is still the best agent for a most effective enamel etching.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Triatoma baratai Carcavallo & Jurberg, is a wild (i.e., nonperidomestic) species found in the State of Mato Grosso do Sul (Bodoquena region, county of Bonito), Brazil. Its eggs and nymphs are described here based on optical and scanning electron microscopy. The operculum and exochorion have pentagonal, hexagonal, and heptagonal cells, with small cracks and small random pits. Differences in the eggs and five nymphal instars of T. baratai allow them to be distinguished from the sympatric species Triatoma williami Galvão, Souza & Lima, and from six of the nine members of the Triatoma oliveirai complex. The most useful differentiating characters are in the color, shape of the abdomen, head, and total body length. Keys are provided to separate the eggs and nymphal instars of six of the nine members of the Triatoma oliveirai species complex. Copyright ©2009 Magnolia Press.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new device for irrigation, which presents hydrodynamic activation based on the pressure-suction technology, has recently been introduced to the market: the Rinsendo system. This study compared the efficacy of the Rinsendo system and conventional (manualdynamic) irrigation in the removal of debris from the root canal walls, using scanning electron microscopy (SEM). Twenty mandibular premolars with completely formed roots were selected and randomly divided into group 1 (irrigation with the Rinsendo system) and group 2 (conventional irrigation). The canals were irrigated with 1 ml of saline at each change of instrument. instrumentation started with a #15 K file and continued up to a #40 K file, which was standardized as the working length instrument. Then, the teeth were sectioned in buccolingual direction and the halves were sputter-coated with gold and examined by SEM. The apical, middle and cervical root canal thirds were evaluated, and the results were analyzed statistically by the Mann-Whitney test for comparison between methods, Kruskal-Wallis test for comparison among thirds, and Miller test for individual comparisons. A significance level of 5% was set for all analyses. The results did not show significant differences (p>0.05) between methods at each third and among thirds for each technique analyzed individually. in conclusion, there was no difference in the cleaning ability of the Rinsendo system and conventional irrigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the efficacy of 2 types of rotary instruments employed in association with sodium hypochlorite (NaOCl) or EDTA in removing calcium hydroxide (CH) residues from root canals dentin walls. Forty-two mandibular human incisors were instrumented with the ProTaper System up to F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA and filled with a CH intracanal dressing. After 7 days, the CH dressing was removed using 4 techniques: NiTi rotary instrument size 25, 0.06 taper (K3 Endo) and irrigation with 17% EDTA (Group 1), NiTi rotary F1 instrument (ProTaper) and irrigation with 17% EDTA (Group 2), NiTi rotary instrument size 25, 0.06 taper and irrigation with 2.5% NaOCl (Group 3) and NiTi rotary F1 instrument and irrigation with 2.5% NaOCl (Group 4). Two roots without intracanal dressing were used as negative controls. Teeth were evaluated by scanning electron microscopy, in the cervical and apical canal thirds. None of the techniques removed the CH dressing completely. In the apical and cervical thirds, F1 instrument was better than instrument size 25, 0.06 taper in removing CH residues (p<0.05), regardless of the final irrigating solution. No difference was found between the irrigating solutions in the groups of F1 instrument and of instrument size 25, 0.06 taper (p>0.05). The negative controls had no CH residues on the dentin walls. In conclusion, the ProTaper F1 instrument was better than K3 Endo instrument size 25, 0.06 taper in the removal of CH intracanal medication, regardless of irrigating solution used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ITO nanowires were synthesized by carbothermal reduction process, using a co-evaporation method, and have controlled size, shape, and chemical composition. The electrical measurements of nanowires showed they have a resistance of about 102 Ω. In order to produce nanocomposites films, nanowires were dispersed in toluene using an ultrasonic cleaner, so the PMMA polymer was added, and the system was kept under agitation up to obtain a clear suspension. The PMMA polymer was filled with 1, 2, 5 and 10% in weight of nanowires, and the films were done by tape casting. The results showed that the electrical resistance of nanocomposites changed by over 7 orders of magnitude by increasing the amount of filler, and using 5 wt% of filler the composite resistance decreased from 1010 Ω to about 104 Ω, which means that percolation threshold of wires occurred at this concentration. This is an interesting result once for nanocomposites filled with ITO nanoparticles is necessary about 18% in weight to obtain percolation. The addition of filler up to 10 wt% decreased the resistance of the composite to 103 Ω, which is a value close to the resistance of wires. The composites were also analyzed by transmission electron microscopy (TEM), and the TEM results are in agreement with the electrical ones about percolation of nanowires. These results are promising once indicates that is possible to produce conductive and transparent in the visible range films by the addition of ITO nanowires in a polymeric matrix using a simple route. © 2011 Materials Research Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate commercially pure titanium implant surfaces modified by laser beam (LS) and LS associated with sodium silicate (SS) deposition, and compare them with machined surface (MS) and dual acid-etching surfaces (AS) modified. Topographic characterization was performed by scanning electron microscopy-X-ray energy dispersive spectroscopy (SEM-EDX), and by mean roughness measurement before surgery. Thirty rabbits received 60 implants in their right and left tibias. One implant of each surface in each tibia. The implants were removed by reverse torque for vivo biomechanical analysis at 30, 60, and 90 days postoperative. In addition, the surface of the implants removed at 30 days postoperative was analyzed by SEM-EDX. The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of LS and SS were statistically higher than AS and MS. At 30 days, values removal torque LS and SS groups showed a statistically significant difference (p < 0.05) when compared with MS and AS. At 60 days, groups LS and SS showed statistically significant difference (p < 0.05) when compared with MS. At 90 days, only group SS presented statistically higher (p < 0.05) in comparison with MS. The authors can conclude that physical chemistry properties and topographical of LS and SS implants increases bone-implant interaction and provides higher degree of osseointegration when compared with MS and AS. © 2012 Wiley Periodicals, Inc.