314 resultados para correlation coefficient


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Paracoccidioidomycosis (PCM) is endemic in Latin America and in countries like Brazil it carries a high mortality rate. The fungus' habitat has not been precisely determined. The present study aims to identify ecologic correlates based on PCM distribution in a hyper-endemic area in southeastern Brazil. The Geographic Information System (GIS) and spatial statistics were used to associate environmental attributes, human population density and, PCM distribution. By means of the Pearson r correlation coefficient, the highest statistically significant associations with prevalence density were the percent area (by county) of: basaltic rocks (r = 0.63; P < 0.0001), Podzolic soils (r = - 0.48; P < 0.001), Latosol soils (r = 0.40; P < 0.01), mean annual precipitation between 1500 and 1600 mm (r = 0.46; P < 0.001) and, mean precipitation during the wet season between 940 and 1040 mm (r = - 0.44; P < 0.01). Soil texture and precipitation analyzed together reached r = 0.61 (P < 0.000002) for fine-textured soils with annual precipitation above 1400 mm. Environmental correlates indicate that moisture availability plays an important role in PCM distribution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Multidrug-resistant Pseudomonas aeruginosa is a major threat in healthcare settings. The use of antimicrobials can influence the incidence of resistant strains by direct and indirect mechanisms. The latter can be addressed by ecological studies. Methods: Our group attempted to analyze the relation between the use of antipseudomonal drugs and the incidence of MDR-PA among 18 units from a 400-bed teaching hospital. The study had a retrospective, ecological design, comprising data from 2004 and 2005. Data on the use of four antimicrobials (amikacin, ciprofloxacin, ceftazidime and imipenem) were tested for correlation with the incidence of MDR-PA (defined as isolates resistant to the four antimicrobials of interest) in clinical cultures. Univariate and multivariate linear regression analyses were performed. Results: Significant correlations were determined between use and resistance for all antimicrobials in the univariate analysis: amikacin (standardized correlation coefficient = 0.73, p = 0.001); ciprofloxacin (0.71, p = 0.001); ceftazidime (0.61, p = 0.007) and imipenem (0.87, p < 0.001). In multivariate analysis, only imipenem (0.67, p = 0.01) was independently related to the incidence of multidrug-resistant strains. Conclusions: These findings share similarities with those reported in individual-based observational studies, with possible implications for infection control.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: This study evaluated whether there is a relationship between the zona pellucida birefringence (ZP-BF) intensity and the nuclear (NM) and cytoplasmic (CM) in vitro maturation of human oocytes from stimulated cycles.Results: The ZP-BF was evaluated under an inverted microscope with a polarizing optical system and was scored as high/positive (when the ZP image presented a uniform and intense birefringence) or low/negative (when the image presented moderate and heterogeneous birefringence). CM was analyzed by evaluating the distribution of cortical granules (CGs) throughout the ooplasm by immunofluorescence staining. CM was classified as: complete, when CG was localized in the periphery; incomplete, when oocytes presented a cluster of CGs in the center; or in transition, when oocytes had both in clusters throughout cytoplasm and distributed in a layer in the cytoplasm periphery Nuclear maturation: From a total of 83 germinal vesicle (GV) stage oocytes, 58 of oocytes (69.9%) reached NM at the metaphase II stage. From these 58 oocytes matured in vitro, the high/positively scoring ZP-BF was presented in 82.7% of oocytes at the GV stage, in 75.8% of oocytes when at the metaphase I, and in 82.7% when oocytes reached MII. No relationship was observed between NM and ZP-BF positive/negative scores (P = 0.55). These variables had a low Pearson's correlation coefficient (r = 0.081). Cytoplasmic maturation: A total of 85 in vitro-matured MII oocytes were fixed for CM evaluation. Forty-nine oocytes of them (57.6%) showed the complete CM, 30 (61.2%) presented a high/positively scoring ZP-BF and 19 (38.8%) had a low/negatively scoring ZP-BF. From 36 oocytes (42.3%) with incomplete CM, 18 (50%) presented a high/positively scoring ZPBF and 18 (50%) had a low/negatively scoring ZP-BF. No relationship was observed between CM and ZP-BF positive/negative scores (P = 0.42). These variables had a low Pearson's correlation coefficient (r = 0.11).Conclusions: The current study demonstrated an absence of relationship between ZP-BF high/positive or low/negative score and nuclear and cytoplasmic in vitro maturation of oocytes from stimulation cycles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo do estudo foi comparar a influência da idade na massa muscular e na força muscular, de membros superiores e inferiores, em mulheres acima de 40 anos. Foram estudadas 52 voluntárias, divididas em 3 grupos etários: 40-49 anos(G40, n=16), 50-59 anos(G50, n=18) e 60-70 anos(G60, n=18). Avaliaram-se: massa muscular (MM) por impedância bioelétrica e força muscular-1RM (FM). Para estatística, utilizaram-se análise variância-one-way, teste de Duncan e correlação de Pearson. Observou-se diferença significativa (p<0,05) entre 10,1% na MM entre G40 e G50 e 7,5% entre G50 e G60, totalizando 16,8% nas duas décadas (G40/G60). A FM de membros inferiores foi 16,4% menor entre G40 e G50 e 12,5% entre G50 e G60, perfazendo 25,3% nas duas décadas (p<0,05). Nos membros superiores, não houve diferença significativa da força, entre G40 e G50 (3,3% supino reto e 2,5% rosca direta) e entre G50 e G60 (17,5% e 9,6%), totalizando, nas duas décadas, 20,2% e 12,2%, respectivamente. A Soma das FMs foi corrigida pela MM (FMs/MM), não apresentando diferenças estatísticas entre os grupos. Correlacionando-se MM e FM, houve maior analogia nos membros inferiores (r=0,57), quando comparados aos membros superiores (r=0,42 e r=41, respectivamente). Concluíu-se que as mulheres apresentaram menores valores de MM e de FM nos membros inferiores logo na quinta década de vida. A FMs/MM parece não se alterar em mulheres entre 40 e 60 anos, quando comparadas por grupos etários. A MM reduzida parece ser fator importante para os menores valores de FM observados em mulheres entre 40 e 60 anos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. To develop and validate a new short and simple measure of health-related quality of life (HRQL) in children with juvenile idiopathic arthritis (JIA).Methods. The Paediatric Rheumatology Quality of Life Scale (PRQL) is a 10-item questionnaire that explores HRQL in two domains: physical health (PhH) and psychosocial health (PsH). Validation of the parent proxy report and child self-report versions of the instrument was accomplished by evaluating 472 JIA patients and similar to 800 healthy children. Validation analyses included assessment of feasibility, face and content validity; construct and discriminative ability; internal structure and consistency; test-retest reliability; responsiveness to clinical change; and minimal clinically important difference.Results. The PRQL was found to be feasible and to possess both face and content validity. The PRQL score correlated in the predicted range with most of the other JIA outcome measures, thereby demonstrating good construct validity, and discriminated well between different levels of disease severity. Assessment of internal structure (factor analysis) revealed that the PhH and PsH subscales identify two unambiguously separated domains. The internal consistency (Cronbach's alpha) was 0.86. The intraclass correlation coefficient for test-retest reliability was 0.91. The PRQL revealed fair responsiveness, with a standardized response mean of 0.67 in improved patients. Overall, the PRQL appeared to be more able to capture physical HRQL than psychosocial HRQL.Conclusion. The PRQL was found to possess good measurement properties and is, therefore, a valid instrument for the assessment of HRQL in children with JIA. This tool is primarily proposed for use in standard clinical care.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

TEMA: a literatura aponta para a influência da postura corporal sobre as habilidades orais em crianças com desenvolvimento sensório-motor alterado. em crianças normais existem poucos estudos sobre essa relação. OBJETIVO: estudar em crianças a termo a relação entre habilidades motoras e habilidades motoras orais, desde 1 dia de vida até 24 meses de idade. MÉTODO: 42 crianças foram filmadas com 1 dia, 1 mês, 2, 3, 4, 5, 6, 9,12 e 24 meses nas posições supino, prono, sentado e em pé e durante alimentação com amamentação / mamadeira (até 5 meses), uso de colher para alimentação pastosa (3 aos 12 meses), uso de copo para água ou suco (6 aos 24 meses) e alimento sólido (6 aos 24 meses). Estabeleceram-se escores de quantificação para o desenvolvimento corporal e habilidades orais e utilizou-se o coeficiente de correlação de Pearson para o estudo estatístico, adotando-se nível de significância de 5%. RESULTADOS: os resultados do desenvolvimento motor apontaram para semelhança de dados entre supino e prono e sentado e em pé; para as habilidades orais (durante a alimentação com mamadeira/amamentação, colher, copo, mastigação) constatou-se em cada modalidade de alimentação, homogeneidade de aquisição de habilidades para lábios, língua e mandíbula. Houve associação entre habilidades motoras e orais; resultados apontam que o desenvolvimento motor (habilidades motoras) se deu antes das orais desde o 5° ao 24° mês e que as habilidades de mandíbula em copo e colher ocorreram antes das habilidades de lábios e língua. CONCLUSÃO: houve crescente aquisição de habilidades motoras e orais, variabilidade de habilidades em idades entre 3 e 24 meses e associação entre habilidades motoras e orais.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The zoonoses toxoplasmosis and leishmaniasis are important worldwide and also affect wild animals. Thus, the present study aimed to assess the prevalence of Leishmania spp. and Toxoplasma gondii antibodies in 52 serum samples from captive crab-eating foxes (Cerdocyon thous) kept in 17 zoos in São Paulo State, Brazil. Modified agglutination test (MAT, for toxoplasmosis) and indirect fluorescent antibody test (IFAT, for toxoplasmosis and leishmaniasis) were employed with heterologous anti-dog immunoglobulin. Antibodies to T. gondii were found in 19.2% animals, with an almost perfect concordance (kappa = 0.86; standard error = 9.31%; CI95% = 68.25-104.76%; P < 0.0001) and a strong correlation coefficient (rs = 0.87; P < 0.0001), which allows the use of heterologous anti-dog immunoglobulin to perform IFAT for toxoplasmosis in crab-eating foxes. No sample was positive for Leishmania spp. Toxoplasmosis infection occurs in wild animals from the studied Brazilian zoos, which indicates a probable environmental contamination, highlighting the importance of appropriate zoo management and the action of the parasite as a sentinel to human infection. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the indirect immunoperoxidase virus neutralization (IPVN) and mouse neutralization test (MNT) to detect antibodies against rabies virus from vaccinated dogs and cattle. The IPVN was set up for the ability to measure 0.5 International Units/ml (IU) of antibody required by the World Health Organization and the Office International des Epizooties as the minimum response for proof of rabies immunization. IPVN was developed and standardized in chicken embryo related (CER) cell line when 141 dog and 110 cattle sera were applied by serial five-fold dilutions (1:5, 1:25, 1:125) as well as the positive and negative reference controls, all added in four adjacent wells, of 96-well microplates. A 50 µl amount of CVS32 strain dilution containing 50-200 TCID50/ml was mixed to each serum dilution, and after 90 min 50 µl of 3 x 10(5) cells/mlcell suspension added to each well. After five days of incubation, the monolayers were fixed and the IPVN test performed. The correlation coefficient between the MNT and IPVN performed in CER cells was r = 0.9949 for dog sera (n = 100) and r = 0.9307 for cattle sera (n = 99), as well as good specificity (94.7%), sensitivity (87.5%), and agreement (96.6%) were also obtained. IPVN technique can adequately identify vaccinated and unvaccinated animals, even from low-responding vaccinated animals, with the advantage of low cost and faster then MNT standard test.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The objective of the study was to analyze 2-flap designs for surgical extraction of third molar, evaluating the periodontal status of the second lower molar.Study Design: Forty-five lower third molars were extracted from 24 patients. In 23 teeth, a vertical incision to the mandibular ramus was used (technique A), whereas 22 teeth were submitted to classic L-shaped flap (technique B) with controls at 60 and 90 days postoperatively.Results: Pearson correlation coefficient analysis showed a significant correlation only between immediate preoperative probing depth variables from techniques A and B in the studied surfaces. Statistical significances in the preoperative (vestibular) and postoperative day 60 (distovestibular and vestibular) were noted. In contrast, Student t-test showed no statistical difference in probing depths between preoperative and postoperative values, as well as no statistically significant difference regarding the type of incision alone.Conclusions: Technique A allowed a less traumatic surgery, guaranteeing a more comfortable postoperative period.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: the incidence of gingival overgrowth (GO) associated with the use of cyclosporin A (CsA) is controversial. In the present study, we determined the incidence of GO in Brazilian renal transplant patients treated with CsA and the possible associations between periodontal and pharmacological variables.Methods: the test group consisted of 20 renal transplant patients, and the control group included 20 non-transplant patients. Periodontal conditions were evaluated based on the plaque index (PI), gingival index (GI), probing depth (PD), and the rate of gingival overgrowth, together with pharmacological variables (daily CsA dose and duration of treatment).Results: A significant difference in PI (P<0.0001) and PD (P<0.0001) was observed between groups, while GI (P=0.15) did not differ significantly. Using the Pearson correlation coefficient, a significant correlation was observed not only between GI (P<0.001; r=0.8141) and GO, but also for PD (P<0.001; r=0.866) and GO. The other correlations were not statistically significant.Conclusions: We conclude that GO induced by CsA may vary according to the individual sensitivity of each patient and may or may not be correlated with other local factors (periodontal variables).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

P>AimTo compare the efficacy of different digital radiographic imaging systems for determining the length of endodontic files.MethodologyK-type endodontic files were introduced into the canals of 40 extracted human permanent single-rooted teeth and fixed in place at random lengths. The teeth were radiographed using Digora Optime (R), CygnusRay MPS (R) and CDR Wireless (R) digital imaging systems. Six observers measured every file length in all the images and repeated this procedure in 50% of the image samples, and assigned a score to the level of difficulty found. Analysis of variance for differences between digital systems and Tukey's test were performed. The level of intraobserver agreement was measured by intraclass correlation. The assigned scores were evaluated by Kruskal-Wallis and Dunn's tests.ResultsThe CDR Wireless values did not differ significantly from the actual lengths and the CygnusRay MPS values. The Digora Optime system was significantly different from the others and overestimated the values (P < 0.05). The Digora Optime was significantly easier to use for taking measurements and the CygnusRay MPS the most difficult (P < 0.05). All digital radiographic imaging systems showed excellent agreement with the Intraclass Correlation Coefficient > 0.95.ConclusionsThe three digital radiographic imaging systems were precise. The CDR Wireless system was significantly more accurate in determining endodontic file lengths, and similarly to Digora Optime, was considered the least difficult to use when assessing endodontic file lengths.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)