195 resultados para avaliação de desempenho


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a study about the use of standards and directions on parallel programming in distributed systems, using the MPI standard and PETSc toolkit, performing an analysis of their performances over certain mathematic operations involving matrices. The concepts are used to develop applications to solve problems involving Principal Components Analysis (PCA), which are executed in a Beowulf cluster. The results are compared to the ones of an analogous application with sequencial execution, and then it is analized if there was any performance boost on the parallel application

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to develop, implement and evaluate the performance of a new type of bioreactor for anaerobic treatment of wastewater using different filling materials like trickling filters post-reactor. This bioreactor has mixed characteristics of the UASB reactors and horizontal flow from the point of view of removal of BOD (Biochemical Oxygen Demand) ssed (settled solids), TS (Total Solids), SS (Suspended Solid), SD (Dissolved Solids) and turbidity. The experimental model consists of a bioreactor with a volume of 12 m³, 2/3 filled by fluidized bed and 1/3 for fixed. The fluidized bed is made of polystyrene plates used as a system percolation and compartmentalized trickling filters, where each compartment was filled with a support medium with different characteristics (gravel number 4, plastic rings of polystyrene, PET and HDPE) . In addition, the output of a filter system was installed three entries filled with activated carbon. The bioreactor was installed in private residence in the city of Igarapava-SP (20° 02'40.18"S and 47° 45'01.36" W). The system was highly efficient as the removal of organic contaminant load 92% on average reducing the BOD, a significant result when compared to other anaerobic systems. For the other parameters, the mean reduction was 96% for turbidity, 99% ssed, 67.5% ST, 57% SD and 88% of SS. As for its operation the system was capable of operating in continuous flow without the need for maintenance during the entire period of evaluation and without energy, as it operates taking advantage of the natural slope of the terrain where it is installed. The environmental impacts were minimized due to the preservation of local vegetation allowing the ecosystem to remain unchanged beyond the prototype was completely sealed preventing exhalation of odors and therefore not causing inconvenience to neighboring populations. Given these facts it was concluded that the prototype is shown to be highly feasible deployed as a new alternative for treatment of sewage in rural and urban settings (individual homes, condos, farms, ranches, etc.) Due to ease of design and operability, and sustainability at all stages of execution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The lead contamination in children has been the subject of research in the field of public health. This study evaluated the academic performance of 102 children from first to fourth grade. The subjects were divided into two groups. The first group was composed of 34 children without lead poisoning or with poison at levels lower than 5 µg/dl. The second group was composed of 68 children with blood lead levels between 10 and 40 µg/ dl. The instruments used to evaluate the academic performance were anamnesis and a scholarly performance test called Teste de Desempenho Escolar, TDE. The results indicated better academic performances from the second group with significant differences in arithmetic, reading and general scores. In a comparison between genders, the girls had better performances than the boys. These results were consistent with the parents’ perception in anamnesis. Although other variables were present, the data showed great academic damage for children with higher leadpoison. These outcomes require political policies to control contamination and intervention in this population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to investigate the performance of an experimental rainwater treatment system for non-potable uses. Without the first-flush discharge it was expected to control the quality of captured rainwater and to minimize the rainwater by-pass caused by the first-flush strategy. A full-scale direct filtration unit was operated and a solution of natural corn starch was used as the primary coagulant. The color, turbidity e coliform efficiencies of the unit was analyzed based on filtration loads and the net water production was estimated. The results pointed out turbidity removal up to 70.8% and color removal up to 61.0%. The backwash of the filtering system was completed in 3 minutes at the rate of 1,440 m3/m2day with consumption of treated water from 0.5% to 2.2%, based on the potentially harvesting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho aborda a natação para a pessoa com deficiência (PCD), tendo como objetivo verificar o nível de desempenho aquático de participantes do projeto de ensino de natação adaptada. Destacamos o intuito de avaliar a perspectiva de início de um treinamento paralímpico em natação. Foram analisados 14 usuá- rios da Sorri-Bauru, vinculados a um programa de iniciação, quanto ao seu nível de desempenho na água. Verificamos que a grande maioria ainda encontra-se em fase inicial da aprendizagem dos estilos, onde a respiração e a autonomia no meio líquido ainda necessitam ser amplamente dominadas. Porém, a partir dos resultados é possível propor o início do processo de treinamento criando um vínculo entre a PCD e o professor/técnico e que sejam respeitadas as limitações e potencialidades dos participantes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia Animal - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sunflower oleaginous is the fourth of recognized importance in the oil production and few studies related to agricultural operations adopted for this crop. The objective of the present work was to study the performance of agricultural machines in the conventional tillage and reduced in the plantation of the sunflower crop. The experiment was installed at the Experimental Farm of Lageado, belonging to the Faculty of Agricultural Sciences of UNESP, located in Botucatu-SP. It consisted of two types of tillage (conventional tillage-CC and reduced tillage-CR), with experimental design in randomized blocks and four replications. The treatment CC promoted less coverage of the soil surface protected with waste when compared to CR treatment. The chisel plow was the tillage of equipment that required the tractor higher average traction force, average power traction and slippage, consequently, promoted lower average speed of work. The theoretical field capacity and area of land involved in the treatment CR were superior when compared to treatment CC, thereby lower consumption of fuel per hour worked was lower in CR treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A avaliação do desempenho de barras de pulverização pode ser feita com base no padrão de distribuição ou deposição do líquido de cada bico individual em mesa de prova. Neste trabalho, compararam-se os padrões de deposição produzidos por diversos bicos em várias alturas. Os resultados mostraram melhor desempenho para os bicos TF e XR, seguido por TJ60-8010, TJ60-8006 e FL. Os bicos TJ60-11006 e TQ mostraram problemas localizados e TK foi considerado o pior entre os testados. Foram propostos modelos para representar as relações entre estatísticas obtidas no padrão e na altura do alvo.