54 resultados para automated instruments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: This clinical report presents a new method for retrieving separated instruments from the root canal with minimally invasive procedures. Background: The presence of separated instrument in root canal may interfere in the endodontic treatment prognosis. There are several recommended methods to retrieve separated instruments, but some are difficult in clinically practice. Case report: This study describes two cases of separated instrument removal from the root canal using a stainless-steel prepared needle associated with a K-file. Case 1 presented a fractured gutta-percha condenser within the mandibular second premolar, it was separated during incorrect intracanal medication calcium hydroxide placement. Case 2 had a fractured sewing needle within the upper central incisor that the patient used to remove food debris from the root canal. After cervical preparation, the fractured instruments were fitted inside a prepared needle and then an endodontic instrument (#25 K-file) was adapted with clockwise turning motion between the needle inner wall and the fragment. Conclusion: The endodontic or atypical nonendodontic separated instrument may be easily pull on of the root canal using a single and low cost device. Clinical significance: The methods for retrieving separated instruments from root canal are difficult and destructive procedures. The present case describes a simple method to solve this problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To describe the surgical technique and initial experience with a single-port retroperitoneal renal biopsy (SPRRB).Materials and Methods: Between January and April 2013, five children underwent SPRRB in our hospital. A single 1.5 cm incision was performed under the 12th rib at mid-axillary line, and an 11 mm trocar was inserted. A nephroscope was used to identify the kidney and dissect the perirenal fat. After lower pole exposure, a laparoscopic biopsy forceps was introduced through the nephroscope working channel to collect a renal tissue sample.Results: SPRRB was successfully performed in five children. The mean operative time was 32 minutes, and mean estimated blood loss was less than 10 mL. The hospital stay of all patients was two days because they were discharged in the second postoperative day, after remaining at strict bed rest for 24 hours after the procedure. The average number of glomeruli present in the specimen was 31.Conclusion: SPRRB is a simple, safe and reliable alternative to open and videolaparoscopic approaches to surgical renal biopsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of self-adaptive software (SaS) has specific characteristics compared to traditional one, since it allows that changes to be incorporated at runtime. Automated processes have been used as a feasible solution to conduct the software adaptation at runtime. In parallel, reference model has been used to aggregate knowledge and architectural artifacts, since capture the systems essence of specific domains. However, there is currently no reference model based on reflection for the development of SaS. Thus, the main contribution of this paper is to present a reference model based on reflection for development of SaS that have a need to adapt at runtime. To present the applicability of this model, a case study was conducted and good perspective to efficiently contribute to the area of SaS has been obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study is an analytical review of the methodology used in studies of efficacy of screening instruments to detect harmful use/ alcohol dependence according to the gender in population surveys. Systematic review of bibliography was done, using data from Web of Science, Pubmed and PsycInfo. Population studies were included without date range, in English, Spanish or Portuguese languages, with sample of adults, evaluating psychometric characteristics of any alcohol screening instrument, whereas studies in special population or under treatment as well as prevalence of alcohol consumption were excluded. Thirteen studies were selected to be included in the present review. According to the studies, the instruments that presented a better performance among men were AUDIT and its derivatives (6 studies) and CAGE (2 studies), whereas among women, AUDIT and its derivatives (7 studies), followed by CAGE (3 studies). The increase of consumption and problems related to alcohol use and its implications for public health indicate the need and urgency for adequacy of screening instruments to differences of gender in general population. The population surveys in the area are scarce. Furthermore, the found studies present heterogeneous methodology which makes accurate comparisons difficult.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Insulin resistance is a common risk factor in chronic kidney disease patients contributing to the high cardiovascular burden, even in the absence of diabetes. Glucose-based peritoneal dialysis (PD) solutions are thought to intensify insulin resistance due to the continuous glucose absorption from the peritoneal cavity. The aim of our study was to analyse the effect of the substitution of glucose for icodextrin on insulin resistance in non-diabetic PD patients in a multicentric randomized clinical trial. This was a multicenter, open-label study with balanced randomization (1:1) and two parallel-groups. Inclusion criteria were non-diabetic adult patients on automated peritoneal dialysis (APD) for at least 3 months on therapy prior to randomization. Patients assigned to the intervention group were treated with 2L of icodextrin 7.5%, and the control group with glucose 2.5% during the long dwell and, at night in the cycler, with a prescription of standard glucose-based PD solution only in both groups. The primary end-point was the change in insulin resistance measured by homeostatic model assessment (HOMA) index at 90 days. Sixty patients were included in the intervention (n = 33) or the control (n = 27) groups. There was no difference between groups at baseline. After adjustment for pre-intervention HOMA index levels, the group treated with icodextrin had the lower post-intervention levels at 90 days in both intention to treat [1.49 (95% CI: 1.23-1.74) versus 1.89 (95% CI: 1.62-2.17)], (F = 4.643, P = 0.03, partial η(2) = 0.078); and the treated analysis [1.47 (95% CI: 1.01-1.84) versus 2.18 (95% CI: 1.81-2.55)], (F = 7.488, P = 0.01, partial η(2) = 0.195). The substitution of glucose for icodextrin for the long dwell improved insulin resistance measured by HOMA index in non-diabetic APD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of peritoneal dialysis modality on patient survival and peritonitis rates is not fully understood, and no large-scale randomized clinical trial (RCT) is available. In the absence of a RCT, the use of an advanced matching procedure to reduce selection bias in large cohort studies may be the best approach. The aim of this study is to compare automated peritoneal dialysis (APD) and continuous ambulatory peritoneal dialysis (CAPD) according to peritonitis risk, technique failure and patient survival in a large nation-wide PD cohort. This is a prospective cohort study that included all incident PD patients with at least 90 days of PD recruited in the BRAZPD study. All patients who were treated exclusively with either APD or CAPD were matched for 15 different covariates using a propensity score calculated with the nearest neighbor method. Clinical outcomes analyzed were overall mortality, technique failure and time to first peritonitis. For all analysis we also adjusted the curves for the presence of competing risks with the Fine and Gray analysis. After the matching procedure, 2,890 patients were included in the analysis (1,445 in each group). Baseline characteristics were similar for all covariates including: age, diabetes, BMI, Center-experience, coronary artery disease, cancer, literacy, hypertension, race, previous HD, gender, pre-dialysis care, family income, peripheral artery disease and year of starting PD. Mortality rate was higher in CAPD patients (SHR1.44 CI95%1.21-1.71) compared to APD, but no difference was observed for technique failure (SHR0.83 CI95%0.69-1.02) nor for time till the first peritonitis episode (SHR0.96 CI95%0.93-1.11). In the first large PD cohort study with groups balanced for several covariates using propensity score matching, PD modality was not associated with differences in neither time to first peritonitis nor in technique failure. Nevertheless, patient survival was significantly better in APD patients.