O objetivo deste trabalho foi desenvolver um método de análise de resíduos do herbicida fluridone em peixes. O herbicida foi extraído do peixe (partes comestíveis), concentrado em colunas de florisil e então analisado em cromatógrafo líquido com detector de UV visível a 313 nm. Os coeficientes de correlação obtidos para linearidade do detector e do método foram de 0,99983 e 0,99987, respectivamente. Com o método descrito foi possível extrair, separar e identificar com eficiência o herbicida fluridone das amostras de peixe, o qual apresentou médias de percentagens de recuperação variando de 60 a 73%. O limite de detecção foi de 20 mg kg-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi ajustar o método espectrofotométrico da 1,5-difenilcarbazida à determinação do crômio em fezes, como marcador biológico, adequando-o à rotina laboratorial. Fatores que poderiam exercer interferência na transformação do crômio (III) à crômio (VI) foram testados, como a recuperação do metal, quantidade de amostra, quantidade e ordem de emprego dos ácidos oxidantes da digestão úmida, temperatura e tempo de digestão e perda por volatilização do crômio como cloreto de cromila, porém não se determinou estatisticamente interferência destes fatores. No método ajustado, a amostra é digerida pela clássica mistura ácida nítrica/perclórica, levando a oxidação do crômio (III) a crômio (VI), e alíquota do extrato diluído é usado para reação com 1,5-difenilcarbazida; as absorbâncias são medidas a 550nm, utilizando-se de cubetas de um centímetro de caminho óptico, contra prova em branco conduzida simultaneamente. Dicromato de potássio foi empregado como substância de referência para obtenção da curva padrão na faixa de 0,25 - 2,5mg.mL-1 de Cr2O3 (1mg Cr2O3 º 1,9355mg K2Cr2O7).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A filtração em múltiplas etapas (FiME) se apresenta como uma alternativa para realizar o tratamento de água de comunidades de pequeno porte, entretanto, a eficiência quanto à remoção de cor verdadeira associada ao carbono orgânico dissolvido (COD) ou às substâncias húmicas, tem sido questionada ou relatada como baixa. A presente pesquisa avaliou a remoção de substâncias húmicas na FiME com pré-oxidação, com ozônio e peróxido de hidrogênio, utilizando para essa avaliação parâmetros indiretos como cor verdadeira, absorvância UV (254 nm) e COD. Foram realizados cinco ensaios, utilizando quatro filtros lentos, sendo dois com camada de carvão ativado granular (CAG). Foram ensaiadas várias alternativas de pré-oxidação com ozônio e peróxido de hidrogênio. Foram obtidos bons resultados, tendo como principal conclusão que os filtros lentos com CAG, precedidos de oxidação com ozônio e depois peróxido de hidrogênio, apresentaram remoção média de cor verdadeira de 64%, mas que o peróxido de hidrogênio afeta o desenvolvimento da camada biológica, interferindo no desenvolvimento da perda de carga, na remoção de turbidez, na remoção de coliformes e na remoção de substâncias húmicas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and sensitive method to determine parts per billion (ppb) of atmospheric formaldehyde in situ, using chromotropic acid, is described. A colorimetric sensor, coupled to a droplet of 15.5 muL chromotropic acid, was constructed and used to sample and quantify formaldehyde. The sensor was set up with two optical fibers, a right emitting diode (LED) and two photodiodes. The reference and transmitted light were measured by a photodetection arrangement that converts the signals into units of absorbance. Air was sampled around the chromotropic acid droplet. A purple product was formed and measured after the sampling terminated (typically 7 min). The response is proportional to the sampling period, analyte concentration and sample flow rate. The detection limit is similar to2 ppb and can be improved by using longer sampling times and/or a sampling flow rate higher than that used in this work, 200 mL min(-1). The present technique affords a simple, inexpensive near real-time measurement with very little reagent consumption. The method is selective and highly sensitive. This sensor could be used either for outdoor or indoor atmospheres.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method for the direct determination of Pb in wines by simultaneous multi-element atomic absorption spectrometry (SIMAAS) using a transversely heated graphite atomizer, Zeeman-effect background corrector and internal standardization is proposed. Bismuth was used as an internal standard and Pd(NO3)(2) plus Mg(NO3)(2) as chemical modifier,to stabilize both the analyte and the internal standard. The implementation of two pyrolysis steps avoided any build-up of carbonaceous residues on the graphite platform. All diluted samples (1 + 1 v/v) in 0.2% v/v HNO3 and reference solutions (5.0-50 mug l(-1) Ph in 0.2% v/v HNO3) were spiked with 25 mug l(-1) Bi. For a 20 mul aliquot dispensed into the graphite tube, a good correlation (r = 0.9997) was obtained between the ratio of the analyte signal to the internal standard signal and the analyte concentration of the reference solutions. The electrothermal behaviour of Pb and Bi in red, white and rose wines were compared. In addition, absorbance variations due to changes in experimental conditions, such as atomizer temperature, integration time, injected sample volume, radiation beam intensity, graphite tube surface, dilution and sample composition, were minimized by using Bi as internal standard. Relative standard deviations of measurements based on integrated absorbance varied from 0.1 to 3.4% and from 0.5 to 7.3% (n = 12) with and without internal standard correction, respectively. Good recoveries (91-104%) for Pb spikes were obtained. The characteristic mass was 45 pg Pb and the limit of detection based on integrated absorbance was 0.9 mug l(-1) Pb. Internal standardization increased the lifetime of the tube by 25%. Direct determinations of Pb in wines with and without internal standardization approaches were in agreement at the 95% confidence level. The repeatability and the tube lifetime were improved when using Bi as internal standard. The improvement in accuracy using an internal standard was only observed when the analytical results were affected by errors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of internal standardization for simultaneous atomic absorption spectrometry (SIMAAS) was investigated for Cd and Pb determination in whole blood. The comparison of thermochemical and physicochemical parameters allowed the selection of Ag, Bi, and Tl as internal standard candidates. Correlation graphs, plotted from the normalized absorbance signals (n = 20) of internal standard (axis y) versus analyte ( axis x), precision and accuracy were used to select Ag as the most appropriate internal standard. Blood samples were diluted (1 + 9) with 0.11% (m/v) Triton X-100 + 1.1% (v/v) HNO3 + 0.28% (m/v) NH4H2PO4 + 10 mug L-1 Ag+. Pyrolysis and atomization temperatures for the optimized heating program were 550 and 1700 degreesC, respectively. Characteristic masses based on integrated absorbance were 1.68 +/- 0.01 pg for Cd and 30.3 +/- 0.1 pg for Pb. The detection limits (DL) were 0.095 +/- 0.001 mug L-1 and 0.86 +/- 0.01 mug L-1 for Cd and Pb, respectively. The mean RSD for all determinations was the same for Cd (13 +/- 9%) with or without Ag as internal standard ( IS). on the other hand, the use of Ag as IS improved the RSD for Pb from 3.6 +/- 4.0% to 2.2 +/- 2.0%. An effective contribution of the internal standard Ag was verified in the recoveries of spiked samples (0.5 mug L-1 Cd2+ and 5.0 mug L-1 Pb2+). The mean recoveries were 81 +/- 8% and 91 +/- 4% for Cd, and 80 +/- 11% and 93 +/- 6% for Pb without and with IS correction, respectively. This is the first application of IS for a simultaneous determination by SIMAAS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow-injection spectrophotometric procedure is proposed for methyldopa determination in pharmaceutical preparations. The determination is based on formation of a yellow product (measured at 410 nm) after complexation of methyldopa with molybdate. Under optimal conditions, Beer's law is obeyed in a concentration range of 50-200 mg l(-1) methyldopa. Typical correlation between absorbance and analyte concentration was 0.9999. Usual excipients used as additives in pharmaceuticals do not interfere with the proposed method. The analytical frequency was 210 h(-1) and the relative standard deviation (R.S.D.) was <= 2% for sample solution containing 150 mg l(-1) methyldopa (n = 11). The analytical results obtained in commercial formulations by applying the proposed FIA method were in good agreement with labeled values and those obtained by the Brazilian Pharmacopoeia procedure at 95% confidence level. (C) 2005 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method for the direct determination of Ni in soft drinks by graphite furnace atomic absorption spectrometry using a transversely heated graphite atomizer (THGA), Zeeman-effect background corrector, and Co as the internal standard (IS) is proposed. Magnesium nitrate was used to stabilize both Ni and Co. All diluted samples (1+1) in 0.2% (v/v) HNO3 and reference solutions [5.0-50 mu g L-1 Ni in 0.2% (v/v) HNO3] were spiked with 50 mu g L-1 Co. For a 20-mu L sample dispensed into the atomizer, correlations between the ratio of absorbance of Ni to absorbance of Co and the analyte concentration were close to 0.9996. The relative standard deviation of the measurements varied from 0.5 to 3.4% and 1.0 to 7.0% (n=12) with and without IS, respectively. Recoveries within 98-104% for Ni spikes were obtained using IS. The characteristic mass was calculated as 43 pg Ni and the limit of detection was 1.4 mu g L-1. The accuracy of the method was checked for the direct determination of Ni in soft drinks and the results obtained with IS were better than those without IS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By means of IR spectroscopy, we determined the teeth ablation mechanism by an Er:YAG laser oscillating at 2.94 mum. Ejected dental material, ablated by the laser from human teeth, was deposited on an IR window and the absorption spectra were measured in the range 2500-20,000 nm. Sound teeth were used, and the corresponding film spectra were compared to spectra obtained by traditional methods. The films spectra obtained do not differ appreciably from those obtained by the traditional method for sound teeth, indicating that the material ejected by an Er:YAG represents the tooth condition.The obtained results confirm that a spectroscopic analysis of a tooth treated with an Er:YAG laser can be done measuring the absorbance of a film composed of ejected material without the need to slice it. In addition, we could determine that the laser absorption occurs mainly by the interstitial water, and the temperature elevation of the ejected material does not exceed 60degreesC. (C) 2002 Elsevier B.V. B.V. All rights reserved.