80 resultados para Viral load of HIV


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background &aims: Selenium is an essential mineral for immunological function, performing crucial functions at the cellular level. This micronutrient has been determined to be frequently deficient in HIV infected patients, with correlations between reduced immunological function and greater susceptibility to opportunistic infections. Our aim was to evaluate the influence of time of exposure to antiretroviral therapy (ART) on the biochemical profile of selenium in HIV-infected patients.Methods: We performed a cross-sectional study on 50 HIV-positive men with different quantitations of viral load and CD4+ T cells, who were either receiving or not receiving ART. Dual energy X-ray absorptiometry (DXA) to determine body composition, biochemical analysis of selenium and albumin, anthropometric measurements were performed. The subjects were divided into groups according to the use of ART or not: The Control Group (CG) was 10 treatment-nave volunteers, Group G < 2 was 20 volunteers on ART for less than 2 years, and Group G > 2 was 20 volunteers on ART for >2 years.Results: The body mass index showed that all subjects were of normal weight. The group with a longer time of exposure to ART (G > 2) had undetectable viremia and a higher CD4+ T cell count: 593.1 +/- 234.6 mm(3). Selenium values (mu g/L) were 55.9 +/- 11.9 for CG, 52.1 +/- 10.5 for G < 2, and 66.9 +/- 20.8 for G > 2, with a significant difference between groups G < 2 and G > 2 (p < 0.05), and only G > 2 showed normal selenium values.Conclusions: Most of the men studied showed selenium deficiency, except for the subjects with a longer exposure to antiretroviral treatment. Thus, an adequate selenium concentration is related to better control of virology and of immunologic function. (C) 2014 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Epstein-Barr virus (EBV) and Kaposi's sarcoma associated herpesvirus (KSHV) are consistently associated with lymphoproliferative diseases and cancers in humans, notably in patients with HIV. Our aim was to evaluate whether EBV and/or KSHV viral loads regularly assessed in peripheral blood mononuclear cells (PBMC) correlate with clinical or laboratorial parameters retrieved for patients living with HIV. This was a longitudinal study with a cohort of 157 HIV positive patients attending an academic HIV outpatient clinic in São Paulo State, Brazil. For each patient, up to four blood samples were collected over a 1 year clinical follow-up: on enrolment into the study, and after 4, 8 and 12 months. Total DNA was extracted from PBMC, and EBV and KSHV viral loads were assessed by real time quantitative PCR. Higher viral loads for EBV were significantly associated with high HIV viraemia, a greater number of circulating T CD8+ cells and lack of virological response to the antiretroviral treatment. KSHV viral load was undetectable in virtually all samples. EBV viral load in PBMC correlated with the number of circulating T CD8+ lymphocytes and the response to the antiretroviral therapy in HIV infected patients. In contrast, KSHV was undetectable in PBMC, presumably an effect of the antiretroviral treatment. Therefore, either KSHV infection in the population studied was absent or viral load in PBMC was beyond the analytical limit of the assay.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

HIV infection is associated with disturbances in lipid metabolism due to a host's response mechanism and the current antiretroviral therapy. The pathological appearance and progression of atherosclerosis is dependent on the presence of injurious agents in the vascular endothelium and variations in different subsets of candidate genes. Therefore, the Hha I polymorphism in the apolipoprotein E gene was evaluated in addition to triglycerides, total cholesterol, very low-density lipoprotein (VLDL), LDL, high-density lipoprotein (HDL), and apolipoprotein (apo) Al, B and E levels in 86 Brazilian HIV-infected patients and 29 healthy controls. The allele frequency for apoE in the HIV-infected group and controls was in agreement with data on the Brazilian population. Dyslipidemia was observed in the HIV group and verified by increased levels of triglycerides, VLDL and apoE, and decreased levels of HDL and apoAl. The greatest abnormalities in these biochemical variables were shown in the HIV-infected individuals whose immune function was more compromised. The effect of the genetic variation at the APOE gene on biochemical variables was more pronounced in the HIV-infected individuals who carried the apoE2/3 genotype. The highly active antiretroviral therapy (HAART)-receiving group presented increased levels of total cholesterol and apoE. Dyslipidemia was a predictable consequence of HIV infection and the protease inhibitors intensified the increase in apoE values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The diversity of the V3 loop tip motif sequences of HIV-1 subtype B was analyzed in patients from Botucatu (Brazil) and Montpellier (France). Overall, 37 tetrameric tip motifs were identified, 28 and 17 of them being recognized in Brazilian and French patients, respectively. The GPGR (P) motif was predominant in French but not in Brazilian patients (53.5% vs 31.0%), whereas the GWGR (W) motif was frequent in Brazilian patients (23.0%) and absent in French patients. Three tip motif groups were considered: P, W, and non-P non-W groups. The distribution of HIV-1 isolates into the three groups was significantly different between isolates from Botucatu and from Montpellier (P < 0.001). A higher proportion of CXCR4-using HIV-1 (X4 variants) was observed in the non-P non-W group as compared with the P group (37.5% vs 19.1%), and no X4 variant was identified in the W group (P < 0.001). The higher proportion of X4 variants in the non-P non-W group was essentially observed among the patients from Montpellier, who have been infected with HIV-1 for a longer period of time than those from Botucatu. Among patients from Montpellier, CD4+ cell counts were lower in patients belonging to the non-P non-W group than in those belonging to the P group (24 cells/µL vs 197 cells/µL; P = 0.005). Taken together, the results suggest that variability of the V3 loop tip motif may be related to HIV-1 coreceptor usage and to disease progression. However, as analyzed by a bioinformatic method, the substitution of the V3 loop tip motif of the subtype B consensus sequence with the different tip motifs identified in the present study was not sufficient to induce a change in HIV-1 coreceptor usage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar os serviços do Sistema Único de Saúde brasileiro de assistência ambulatorial a adultos vivendo com aids em 2007 e comparar com a avaliação de 2001. MÉTODOS: Os 636 serviços cadastrados no Ministério da Saúde em 2007 foram convidados a responder a um questionário previamente validado (Questionário Qualiaids) com 107 questões de múltipla escolha sobre a organização da assistência prestada. Analisaram-se as frequências das respostas de 2007 comparando-as com as obtidas em 2001 na forma de variação percentual (VP). RESULTADOS: Responderam o questionário 504 (79,2%) serviços. Cerca de 100,0% dos respondentes relataram ter pelo menos um médico, suprimento sem falhas de antirretrovirais e de exames CD4 e carga viral. Vários aspectos mostraram melhor desempenho em 2007 comparados a 2001: registro de número de faltas à consulta médica (de 18,3 para 27,0%, VP: 47,5%), agendamento de consulta em menos de 15 dias no início da terapia antirretroviral (de 55,3 para 66,2%, VP: 19,7%) e participação organizada do usuário (de 5,9 para 16,7%, VP: 183,1%). Houve manutenção de dificuldades: pequena variação na disponibilidade de exames especializados em até 15 dias, como endoscopia (31,9 para 34,5%, VP: 8,1%), e a piora de indicadores como tempo ideal de acesso a consultas especializadas (55,9 para 34,5% em cardiologia, VP negativa de 38,3%). O tempo médio despendido nas consultas médicas de seguimento manteve-se baixo: 15 minutos ou menos (52,5 para 49,5%, VP negativa de 5,8%). CONCLUSÕES: A avaliação de 2007 mostrou que os serviços contam com os recursos essenciais para a assistência ambulatorial. Houve melhoras em muitos aspectos em relação a 2001, mas persistem desafios. Pouco tempo dedicado à consulta médica pode estar vinculado ao número insuficiente de médicos e/ou à baixa capacidade de escuta e diálogo. A acessibilidade prejudicada a consultas especializadas mostra a dificuldade das infraestruturas locais do Sistema Único de Saúde.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statement of problem. Implant overdenture prostheses are prone to acrylic resin fracture because of space limitations around the implant overdenture components.Purpose. The purpose of this study was to evaluate the influence of E-glass fibers and acrylic resin thickness in resisting acrylic resin fracture around a simulated overdenture abutment.Material and methods. A model was developed to simulate the clinical situation of an implant overdenture abutment with varying acrylic resin thickness (1.5 or 3.0 mm) with or without E-glass fiber reinforcement. Forty-eight specimens with an underlying simulated abutment were divided into 4 groups (n=12): 1.5 mm acrylic resin without E-glass fibers identified as thin with no E-glass fiber mesh (TN-N); 1.5 mm acrylic resin with E-glass fibers identified as thin with E-glass fiber mesh (TN-F); 3.0 mm acrylic resin without E-glass fibers identified as thick without E-glass fiber mesh (TK-N); and 3.0 mm acrylic resin with E-glass fibers identified as thick with E-glass fiber mesh (TK-F). All specimens were submitted to a 3-point bending test and fracture loads (N) were analyzed with a 2-way ANOVA and Tukey's post hoc test (alpha=.05).Results. The results revealed significant differences in fracture load among the 4 groups, with significant effects from both thickness (P<.001) and inclusion of the mesh (P<.001). Results demonstrated no interaction between mesh and thickness (P=.690). The TN-N: 39 +/- 5 N; TN-F: 50 +/- 6.9 N; TK-N: 162 +/- 13 N; and TK-F: 193 +/- 21 N groups were all statistically different (P<.001).Conclusions. The fracture load of a processed, acrylic resin implant-supported overdenture can be significantly increased by the addition of E-glass fibers even when using thin acrylic resin sections. on a relative basis, the increase in fracture load was similar when adding E-glass fibers or increasing acrylic resin thickness. (J Prosthet Dent 2011;106:373-377)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tanomaru-Filho M, Silveira GF, Reis JMSN, Bonetti-Filho I, Guerreiro-Tanomaru JM. Effect of compression load and temperature on thermomechanical tests for gutta-percha and Resilon (R). International Endodontic Journal, 44, 1019-1023, 2011.Aim To analyse a method used to evaluate the thermomechanical properties of gutta-percha and Resilon at different temperatures and compression loads.Methodology Two hundred and seventy specimens measuring 10 mm in diameter and 1.5 mm in height were made from the following materials: conventional gutta-percha (GCO). thermoplastic gutta-percha (GTP) and Resilon (R) cones (RE). After 24 h, the specimens were placed in water at 50 degrees C. 60 degrees C or 70 degrees C for 60 s. After that, specimens were placed between two glass slabs, and loads weighing 1.0, 3.0 or 5.0 kg were applied. Images of the specimens were digitized before and after the test and analysed using imaging software to determine their initial and final areas. The thermomechanical property of each material was determined by the difference between the initial and final areas of the specimens. Data were subjected to ANOVA and SNK tests at 5% significance. To verify a possible correlation between the results of the materials, linear regression coefficients (r) were calculated.Results Data showed higher flow area values for RE under all compression loads at 70 degrees C and under the 5.0 kg load at 60 degrees C (P < 0.05). Regarding gutta-percha, GTP showed higher flow under loads weighing 3.0 and 5.0 kg. at 60 and 70 degrees C (P < 0.05). GCO presented higher flow at 70 degrees C with a load of 5.0 kg. Regression analyses showed a poor linear correlation amongst the results of the materials under the different experimental conditions.Conclusion Gutta-percha and Resilon (R) cones require different compression loads and temperatures for evaluation of their thermomechanical properties. For all materials, the greatest flow occurred at 70 degrees C under a load of 5.0 kg: therefore. these parameters may be adopted when evaluating endodontic tilling materials.