79 resultados para Variable dosage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have shown that the X̄ chart with variable sampling intervals (VSI) and/or with variable sample sizes (VSS) detects process shifts faster than the traditional X̄ chart. This article extends these studies for processes that are monitored by both the X̄ and R charts. A Markov chain model is used to determine the properties of the joint X and R charts with variable sample sizes and sampling intervals (VSSI). The VSSI scheme improves the joint X̄ and R control chart performance in terms of the speed with which shifts in the process mean and/or variance are detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Varying the parameters of the X̄ chart has been explored extensively in recent years. In this paper, we extend the study of the X̄ chart with variable parameters to include variable action limits. The action limits establish whether the control should be relaxed or not. When the X̄ falls near the target, the control is relaxed so that there will be more time before the next sample and/or the next sample will be smaller than usual. When the X̄ falls far from the target but not in the action region, the control is tightened so that there is less time before the next sample and/or the next sample will be larger than usual. The goal is to draw the action limits wider than usual when the control is relaxed and narrower than usual when the control is tightened. This new feature then makes the X̄ chart more powerful than the CUSUM scheme in detecting shifts in the process mean.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and reproducible method was developed for the assay of lomefloxacin in tablets. The excipients in the commercial tablet preparation did not interfere with the assay. Beer's law is obeyed in the range 2.0-9.0 μg.mL-1 at λmax 280 nm. The molar absorptivity was calculated. Six triplicate analyses of solutions containing six different concentrations of the examined drug were carried out and gave a mean correlation coefficient 0.9997. The proposed method was applied to the determination of the examined drug in coated tablet and the results demonstrated that the method is equally accurate, precise and reproducible as the official methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oral administration with solid dosage forms is a common route in the drug therapy widely used. The drug release by the disintegration process occurs in several gastrointestinal tract (GIT) regions. AC Biosusceptometry (ACB) was originally proposal to characterize the disintegration process of tablets in vitro and in the human stomach, through changes in magnetic signals. The aim of this work was to employ a multisensor ACB system to monitoring magnetic tablets and capsules in the human GIT and to obtain the magnetic images of the disintegration process. The ACB showed accuracy to quantify the gastric residence time, the intestinal transit time and the magnetic images allowed to visualize the disintegration of magnetic formulations in the GIT. The ACB is a non-invasive, radiation free technique, completely safe and harmless to the volunteers and had demonstrated potential to evaluate pharmaceutical dosage forms in the human gastrointestinal tract. © 2005 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quercetin, a typical bioflavonoid ubiquitously present in fruits and vegetables, is considered to be helpful for human health. Cisplatin (cDDP) is one of the most active cytotoxic agents in the treatment of a wide range of solid tumors. The aim of this study was to investigate the possible effect of quercetin, a bioflavonoid with antioxidant potential, on cisplatin-induced nophrotoxicity and lipid peroxidation in rats. Gavage administrations of water, propylene glycol and quercetin (50 mg/kg) were made 24 and 1 h before saline or cDDP (5 mg/kg) ip injections and were repeated daily for 2, 5 or 20 subsequent days. Rats were killed 2, 5 and 20 days after ip injections, and blood and urine samples were collected to determine plasma creatinine, urine volume and osmolality. The kidneys were removed to determine the levels of thiobarbituric acid-reactive substances (TBARS) and for histological studies. Cisplatin increased lipid peroxidation, urine volume and plasma creatinine levels and decreased urine osmolality. Treatment with quercetin attenuated these alterations. These results demonstrate the role of oxidative stress and suggest a protective effect of quercetin on cisplatin-induced nephrotoxicity in adult Wistar rats. Copyright © 2006 by Institute of Pharmacology Polish Academy of Sciences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a micellar system of benzathine penicillin G (BPG) in sodium deoxycholate (NaDC) was developed and evaluated physicochemically. The solubility profile of the drug in water and buffer solutions at various pH was determined, as well as its n-octanol/water partition coefficient. The Critical Micellar Concentration of NaDC and its ability to incorporate BPG were also assessed. The study was carried out at low and high ionic strength which was adjusted by the addition of sodium chloride. The results demonstrated the ability of the micellar system to incorporate BPG, as well as to increase its apparent solubility in water. The enhancement of the solubility of BPG by the presence of NaDC micelles could be analyzed quantitatively within the framework of the pseudo-phase model. Concentration analysis showed that the micellar system could attain up to 90% incorporation of BPG. The incorporated drug is expected to exhibit improved stability, since the antibiotic enclosed in the hydrophobic core of micelles is rather shielded from the aqueous external environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents necessary and sufficient conditions for the following problem: given a linear time invariant plant G(s) = N(s)D(s)-1 = C(sI - A]-1B, with m inputs, p outputs, p > m, rank(C) = p, rank(B) = rank(CB) = m, £nd a tandem dynamic controller Gc(s) = D c(s)-1Nc(s) = Cc(sI - A c)-1Bc + Dc, with p inputs and m outputs and a constant output feedback matrix Ko ε ℝm×p such that the feedback system is Strictly Positive Real (SPR). It is shown that this problem has solution if and only if all transmission zeros of the plant have negative real parts. When there exists solution, the proposed method firstly obtains Gc(s) in order to all transmission zeros of Gc(s)G(s) present negative real parts and then Ko is found as the solution of some Linear Matrix Inequalities (LMIs). Then, taking into account this result, a new LMI based design for output Variable Structure Control (VSC) of uncertain dynamic plants is presented. The method can consider the following design specifications: matched disturbances or nonlinearities of the plant, output constraints, decay rate and matched and nonmatched plant uncertainties. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents two Variable Structure Controllers (VSC) for continuous-time switched plants. It is assumed that the state vector is available for feedback. The proposed control system provides a switching rule and also the variable structure control input. The design is based on Lyapunov-Metzler (LM) inequalities and also on Strictly Positive Real (SPR) systems stability results. The definition of Lyapunov-Metzler-SPR (LMS) systems and its direct application in the design of VSC for switched systems are introduced in this paper. Two examples illustrate the design of the proposed VSC, considering a plant given by a switched system with a switched-state control law and two linear time-invariant systems, that are not controllable and also can not be stabilized with state feedback. ©2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 μm was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques. © 2010 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a control method for a class of continuous-time switched systems, using state feedback variable structure controllers. The method is applied to the control of a two-cell dc-dc buck converter and a control circuit design using the software PSpice is proposed. The design is based on Lyapunov-Metzler-SPR systems and the performance of the resulting control system is superior to that afforded by a recently-proposed alternative sliding-mode control technique. The dc-dc power converters are very used in industrial applications, for instance, in power systems of hybrid electric vehicles and aircrafts. Good results were obtained and the proposed design is also inexpensive because it uses electric components that can be easily found for the hardware implementation. Future researches on the subject include the hardware validation of the dc-dc converter controller and the robust control design of switched systems, with structural failures. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a control method for a class of continuous-time switched systems, using state feedback variable structure controllers. The method is applied to the control of a non-trivial dc-dc power converter and a simple and inexpensive control circuit design, that was simulated using the software PSpice, is proposed. The design is based on Lyapunov-Metzler-SPR systems and the performance of the resulting control system is superior to that afforded by a recently proposed alternative sliding-mode control technique. © 2011 IFAC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a bridgeless boost interleaved PFC (power factor correction) converter with variable duty cycle control. The application of bridgeless technique causes reduction of conduction losses, while the interleaving technique of converters cells allows division of efforts in semiconductor devices and reduction of weight and volume of the input EMI filter. The use of variable duty cycle control has the functions of regulating the output voltage and eliminating the low order harmonic components that appears in the input current of the common interleaved power factor converters working in Discontinuous Conduction Mode (DCM). The simulation results of the proposed converter presented high power factor and a good transient response in relation to the output voltage regulation in presence of high load variations and supply voltage variations. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the effects of folic acid supplementation on isolated oral cleft recurrence and fetal growth. Patients and Methods: The study included 2,508 women who were at-risk for oral cleft recurrence and randomized into two folic acid supplementation groups: 0.4 and 4 mg per day before pregnancy and throughout the first trimester. The infant outcome data were based on 234 live births. In addition to oral cleft recurrence, several secondary outcomes were compared between the two folic acid groups. Cleft recurrence rates were also compared to historic recurrence rates. Results: The oral cleft recurrence rates were 2.9% and 2.5% in the 0.4 and 4 mg groups, respectively. The recurrence rates in the two folic acid groups both separately and combined were significantly different from the 6.3% historic recurrence rate post the folic acid fortification program for this population (p = 0.0009 when combining the two folic acid groups). The rate of cleft lip with palate recurrence was 2.9% in the 0.4 mg group and 0.8% in the 4 mg group. There were no elevated fetal growth complications in the 4 mg group compared to the 0.4 mg group. Conclusions: The study is the first double-blinded randomized clinical trial (RCT) to study the effect of high dosage folic acid supplementation on isolated oral cleft recurrence. The recurrence rates were similar between the two folic acid groups. However, the results are suggestive of a decrease in oral cleft recurrence compared to the historic recurrence rate. A RCT is still needed to identify the effect of folic acid on oral cleft recurrence given these suggestive results and the supportive results from previous interventional and observational studies, and the study offers suggestions for such future studies. The results also suggest that high dosage folic acid does not compromise fetal growth. © 2013 by the authors; licensee MDPI, Basel, Switzerland.