128 resultados para Underground dwellings


Relevância:

10.00% 10.00%

Publicador:

Resumo:

North's clustering method, which is based on a much used ecological model, the nearest neighbor distance, was applied to the objective reconstruction of the chain of household-to-household transmission of variola minor (the mild form of smallpox). The discrete within-household outbreaks were considered as points which were ordered in a time sequence using a 10-40 day interval between introduction of the disease into a source household and a receptor household. The closer points in the plane were assumed to have a larger probability of being links of a chain of household-to-household spread of the disease. The five defining distances (Manhattan or city-block distance between presumptive source and receptor dwellings) were 100, 200, 300, 400 and 500 m. The subchain sets obtained with the five defining distances were compared with the subchains empirically reconstructed during the field study of the epidemic through direct investigation of personal contacts of the introductory cases with either introductory or subsequent cases from previously affected households. The criteria of fit of theoretical to empirical clusters were: (a) the number of clustered dwellings and subchains, (b) number of dwellings in a subchain and (c) position of dwellings in a subchain. The defining distance closet to the empirical findings was 200 m, which fully agrees with the travelling habits of the study population. Less close but acceptable approximations were obtained with 100, 300, 400 and 500 m. The latter two distances gave identical results, as if a clustering ceiling had been reached. It seems that North's clustering model may be used for an objective reconstruction of the chain of contagious whose links are discrete within-household outbreaks. © 1984.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Groundwater samples were collected for several months in boreholes drilled at Morro do Ferro, a thorium and rare earth deposit located on the Poços de Caldas Plateau, Minas Gerais State, Brazil. An aquifer system has developed in the weathered mantle due to in situ intense alteration. The weathered zone includes a thick argillaceous laterite greater than 100 m thick. The U content and 324U/238U activity ratio were measured in the groundwater samples and in spoil samples of a borehole drilled in the ore body. Some possible mechanisms related to the mobilization of uranium are considered such as complexation with humic substances and adsorption by clays. © 1989.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Successful application of shallow seismic reflection method is related directly to the ability of the ground to transmit high-frequency seismic energy from a seismic source. The dominant frequencies of reflection data are in the range of 50 to 100 Hz and depend on the surface materials and water table. A spread of geophones send the siemsic signal to be recorded on a 12, 24 or 48 channel portable seismograph, using a single high-frequency geophone per channel. Although it is possible to find seismographs with display and processing unities, it is also possible to transfer digitalized data to a personal computer to be processed and interpreted by using specific programs. Some results of two recent field studies to specify the underground structure in the tidal flats area of Baie St. Paul (Quebec-Canada) and in glacial terrains, in the Waterloo (Ontario-Canada) region. -from English summary

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The problems caused by the residual effluents of wine distilleries for alcohol production are well known. The effluent effects in soil and groundwater are being researched in an area with sugar cane culture which receives, yearly, vinasse by dispersion. Samples are being collected from the soil, the groundwater and the existing creeks in the area. Four sub-areas are being monitored separately with a vinasse application of 300 m 3/ha year. Experimentation periods in each area have been 0, 5, 10 and 15 years. In the unsaturated zone, samples are being collected at depths of 25, 75 and 150 cm. The chemical analyses include macro and micro nutrients, organic matter and pH. Physical analyses give the soil water retention, hydraulic conductivity and soil particle distribution. These measurements permit the evaluation of nitrogen absorption and fertility changes of the soil. A tendency for the maintenance of soil fertility can be observed but with an elevation of nitrate concentration in groundwater.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although conventional rotating machines have been largely used to drive underground transportation systems, linear induction motors are also being considered for future applications owing to their indisputable advantages. A mathematical model for the transient behavior analysis of linear induction motors, when operating with constant r.m.s. currents, is presented in this paper. Operating conditions, like phase short-circuit and input frequency variations and also some design characteristics, such as air-gap and secondary resistivity variations, can be considered by means of this modeling. The basis of the mathematical modeling is presented. Experimental results obtained in the laboratory are compared with the corresponding simulations and discussed in this paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

After the prohibition of organochlorine-pesticide use in Brazil for controlling insect vector diseases, Mato Grosso State gathered the exceeding DDT and stored it irregularly in an open air area that belongs to the National Health Foundation, causing soil contamination. This study aimed to evaluate the contamination level and dissipation of p,p′-DDT and p,p′-DDE in this area. For that, surface soil samples were collected on 19 September 2000, 15 December 2000, 4 April 2001 and soil samples 30-40 cm; 60-70 cm and 90-100 cm deep were taken from five points in the studied area on 17 July 2001. The contaminants were determined by a small scale method which consists on extraction and clean-up steps combined into one step by transferring soil samples mixed with neutral alumina to a chromatographic column prepacked with neutral alumina and elution with hexane:dichloromethane (7:3 v:v). The eluate was concentrated and the analytes were quantified by gas chromatography with an electron-capture detector. p,p′-DDT at surface soil ranged from 3800 to 7300 mg kg -1. 30-40 cm deep soil sample concentrations varied from 0.036 to 440 mg kg -1 while 90-100 cm deep samples varied from 0.069 to 180 mg kg -1. Volatilization is probably the main dissipation process. The p,p′-DDT is moving slowly downward in the soil profile, however, the levels of this contaminant are high enough to present risk to underground waters. © 2005 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project has been developed to evaluate the possible relationship between the cesspit (pit latrine) in as far as it degrades the quality of underground water. Its importance is due to the fact that in the rural communities in the State of São Paulo (Brazil) this type of cesspit is very common as a means of sewage disposal and these communities use underground water for their supply of drinking water. Rural properties distributed over the rural area in the municipality of São José do Rio Preto were selected. A preliminary study was then set up to determine the social situation and health of the households as well as qualitative evaluations on the type of water supply and sewage disposal of these communities. Campaigns of water sampling then followed and laboratory analyses of water taken from wells were carried out. Parameters were set up to evaluate the potability according to Brazilian legislation (2004) paying attention to microbiologic (coliforms, Crytosporidium sp., and adenovirus). The analyses showed evidence of possible interaction between the wells and the sewage effluents and drainage in these communities. A PCR reaction to detect adenovirus showed a presence in 53.3% of the samples. The tests for the detection of Cryotosporidium sp all showed a negative result.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a dedicated algorithm for lation of single line-to-ground faults in distribution systems. The proposed algorithm uses voltage and current phasors measured at the substation level, voltage magnitudes measured at some buses of the feeder, a database containing electrical, operational and topological parameters of the distribution networks, and fault simulation. Voltage measurements can be obtained using power quality devices already installed on the feeders or using voltage measurement devices dedicated for fault location. Using the proposed algorithm, likely faulted points that are located on feeder laterals geographically far from the actual faulted point are excluded from the results. Assessment of the algorithm efficiency was carried out using a 238 buses real-life distribution feeder. The results show that the proposed algorithm is robust for performing fast and efficient fault location for sustained single line-to-ground faults requiring less than 5% of the feeder buses to be covered by voltage measurement devices. © 2006 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to evaluate the bean yield under different water table levels as well as the moisture and nitrate distribution in the soil profile, a field experiment was carried out in the experimental area of the College of Agricultural Sciences - UNESP, Botucatu, SP, Brazil. Beans were grown in field lysimeters under five water table depths: 30; 40; 50; 60 and 70 cm. The moisture in the soil profile was determined gravimetrically using samples collected at 10; 20; 30; 40; 50; 60 and 70 cm deep. The water table depths of 30cm and 40cm showed the highest productivities (3,228.4kg.ha-1 and 3,422.1kg.ha-1, respectively), with no statistical differences between them. The highest productivity was related to the two highest water table levels (30 and 40cm), which provided the highest moisture average values on the basis of volume in the soil profile (33.3 e 31%) as well as the consumptive use of water (416 and 396mm). The nitrate content during the bean cycle at the extraction depth of 60cm was below the safe drinking limit of 10mg.1-1 for water table depths of 30; 40; 50 and 60cm, which shows the denitrification efficiency as a way of controlling nitrate pollution in water tables. The management of water table can lead to high levels of bean yield and to a better control of nitrate pollution in underground water.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Paleogene sediments of this region represent a significant source of water for urban, industrial and agricultural activities. This basin is part of the Southeastern Brazilian Continental Rift, which occupies a large portion of this geographical area. This study aims to present the evolution of the natural Paleogene landscape, through an analysis of its stratigraphic intcrops and underground portions based on the concept of facies and facies associations. A total of nine clastic and separate lithofacies were recognized and grouped into two main facies associations. These data suggest the existence of two depositional interdigitated systems: fluvial braided fans, which were predominant in parts of the northern and central area, and another composed of lacustrine sediments found in its central-south region. The paleogeography herein outlined will help considerably in the detection of new areas for mineral and water resources prospection, as well as in urban planning projects of this region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/. c to 1 TeV/. c. The surface flux ratio is measured to be 1.2766±0.0032(stat.)±0.0032(syst.), independent of the muon momentum, below 100 GeV/. c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments. © 2010.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to lack of environmental protection with which the process of burying the corpses was conducted over the decades, many cemeteries have become areas contaminated by organic and inorganic substances and pathogenic microrganisms. This paper presents the results of electrical imaging in delineation of areas potentially contaminated by necrochorume in the municipal cemetery of Vila Rezende, Piracicaba - SP. The results indicate a depth of water table among 3,1 and 5,1 m, with two flow directions, being one to SW and another to SE. So the probable contamination plume, that has the same directions of underground flow, as for the conductive anomalies verified at the geoelectrics sections confirm the suspicions of contamination in the area. The probable plume the SE is prolonged to out of the cemetery. The location of the conductive anomalies and likely contamination plumes demonstrated that the contamination is linked with the depth of water table level and the burial time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The geoelectrical methods have been widely used in research involving the evaluation and monitoring of areas with environmental risk. This paper presents the results of applying the Electrical Resistivity method by electrical profiling technique to investigate the fuel presence in soil and groundwater proceeding in station gas, located in an urban area Caçapava do Sul (RS), on soil in situ, from modification of Caçapava granite. The results suggest an association between low resistivity anomalies zone with potentially degraded from underground tanks worthless on the form of free phase, now represented as residual phase. The results of the model inversion are consistent with the standards expected for hydrocarbons present in the saturated zone. The electrical resistivity method proved to be an important tool for assessment and environmental monitoring in conjunction with direct methods of investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Ji-Paraná city (RO) it doesn't possess public system of collection and treatment of sewers, being the waters residuárias produced by the local population thrown at sewages. Traditionally, many inhabitants use wells amazon extracted underground water or tubular shallow in the urban zone. The study accomplished in the Nova Brasília neighborhood for Silva (2009) revealed that the local aquifer is strongly contaminated for nitrate, originated of the decomposition of the organic matter deposited at the sewages local maidservants. With the objective of detecting areas with high concentrations originating from organic compositions of septic sewages, geophysical risings were accomplished, later related with analyses physical-chemistries in samples of groundwaters obtained in several wells installed in the Nova Brasília neighborhood, besides of soil samples descriptions in zone not saturated obtained in wells. The results obtained by the geophysical rehearsals they reveal that the polluting feather not migrates through the zone saturated, arriving with relative easiness to the aquifer, reaching in some points, superior depth to 34 m reached by the geoelectrical profiling.