220 resultados para Ultrasonic NDE
Resumo:
To evaluate the influence of variations in the working angle of the piezoelectric ultrasonic scaler (PUS) on root surfaces. Material and methods Fifty-five uniradicular bovine teeth were used, of which 25 teeth were used for the analysis of the roughness and root wear, while the remaining 30 teeth were used for the analysis of morphology (MRS) and the attachment of blood components (ABC). The teeth were randomly divided into five groups according to the type of treatment (G1-G5: piezoelectric ultrasonic scaler; G6: manual curette) and to the PUS working angle applied (G1: 0°; G2: 30°; G3: 45°; G4: 60°; G5: 90°). For statistical analysis, the data describing the MRS and ABC were analysed by the Kruskal–Wallis and Dunn's tests, and the data describing the roughness and tooth wear were analysed by anova and Tukey's tests at the significance level of 5%. Results Manual curette (MC) promoted a smoother root surface than the application of the PUS. The PUS used at the angles of 30° and 45° resulted in a high level of ABC that was comparable to that obtained by MC. Additionally, the group in which the PUS was applied at an angle of 45° exhibited less tooth wear than the other groups. Conclusions Changes in the working angle of the PUS influenced the characteristics of root surfaces after instrumentation.
Resumo:
The effect of ultrasound and osmotic dehydration pretreatments on papaya drying kinetics was investigated. The ultrasound pretreatment was carried out in an ultrasonic bath at 30 A degrees C. The osmotic pretreatment in sucrose solution was carried out in an incubator at 34 A degrees C and agitation of 80 rpm for 210 min. The drying process was conducted in a fixed bed dryer at 70 A degrees C. Experimental data were fitted successfully using the Page model for dried fresh and pretreated fruits, with coefficient of determination greater than 0.9992 and average relative error lower that 14.4 %. The diffusional model was used to describe the moisture transfer, and the effective water diffusivity was identified in the order of 10(-9) m(2) s(-1). It was found that drying rates of osmosed fruits were the lowest due to the presence of infused solutes, while the ultrasound pretreatment contributed to faster drying rates. Evaluation of the dried fruit was performed by means of total carotenoids retention. Ultrasound treatments in distilled water prior to air-drying gave rise to dried papayas with retention of carotenoids in the range 30.4-39.8 % and the ultrasonic-assisted osmotic dehydration of papayas showed carotenoids retention values up to 64.9 %, whereas the dried fruit without pretreatment showed carotenoids retention lower than 24 %.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A madeira de Pinus sp. tem utilização crescente na indústria madeireira brasileira. O decréscimo constante do suprimento de árvores adultas com grandes diâmetros, provenientes de florestas naturais, tornou comum a produção de madeira em ciclos curtos, com grande proporção de madeira juvenil. Resultados de diversas pesquisas têm reportado que o módulo de elasticidade e a resistência a diferentes solicitações mecânicas são seriamente afetados pela presença de madeira juvenil. Este trabalho teve por objetivo determinar o módulo de elasticidade da madeira juvenil e adulta de Pinus taeda L. a partir da constante dinâmica C LL, obtida em ensaios não-destrutivos de ultra-som. A madeira de P. taeda era originária de plantios da Estação Experimental de Itapeva - SP, sendo amostrados seis indivíduos arbóreos com 34 anos de idade. Os corpos-de-prova (4 cm x 4 cm x 45 cm) foram obtidos separadamente das regiões de madeira juvenil e adulta da prancha central, previamente submetida à secagem industrial (umidade final de 12%), para a determinação da constante dinâmica por meio de ensaios de ultra-som. Para avaliar a sensibilidade do método do ultra-som, os corpos-de-prova foram ensaiados destrutivamente à compressão paralela. Os resultados mostraram boa sensibilidade do método do ultra-som (R² » 0,90) na avaliação desse parâmetro mecânico da madeira juvenil e adulta.
Resumo:
The spray drying method was used to prepare luminescent microspheres. These microspheres were prepared by spraying an aqueous solution of dextrin and an europium(III) complex with subsequent drying in a hot medium. The spray dried powder was characterized by scanning electron microscopy (SEM) and photoluminescence spectroscopy (PL). Particle size distribution was estimated from SEM images. The ultrasonic spray drying technique was successfully applied to yield a microparticulated and red luminescent powder composed by the [Eu(dpa)(3)](3-) stop (dpa = dipicolinic acid) complex incorporated in dextrin microspheres.
Resumo:
Stitched fabrics have been widely studied for potential application in aircraft structures since stitch yarns offer improvements in the out-of-plane mechanical properties and also can save time in the lay up process. The down side of stitch yarns came up in the manufacturing process of fabric in which defects introduced by the needle movement creating fiber-free-zones, fiber breakage and misalignment of fibers. The dry stitched carbon fabric preform has mainly been used in the Resin Transfer Molding (RTM) process which high fiber content is aimed, those defects influence negatively the injection behavior reducing the mechanical properties of final material. The purpose of this research work focused on testing in quasi-static mechanical mode (in-plane tension) of a monocomponent resin CYCOM (R) 890 RTM/carbon fiber anti-symmetric quadriaxial fabric stitched by PE 80Dtex yarn processed by RTM. The evaluation consisted in comparing the scatter of the quasi-static test with the attenuation of ultrasonic maps, which show the path of the resin and possible dry spots considering that interference of yarn in resin flow is detectable in ultrasonic measurement. Microscopic analysis was also considered for further evaluation in case of premature failure. (C) 2011 Published by Elsevier Ltd. Selection and peer-review under responsibility of ICM11
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Avaliou-se a espessura corneana central de 13 gatos normais com microscópio especular de não-contato Topcon SP-2000P e paquímetro ultra-sônico. Foi observado aumento da espessura corneana mensurada pelo paquímetro ultra-sônico comparado ao microscópio especular.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objectives were to determine the effects of age and genetic group on characteristics of the scrotum, testes and testicular vascular cones (TVC), and on sperm production and semen quality in 107 Bos indicus, B, taurus and cross-bred bulls at three artificial insemination (AI) centers in Brazil. In addition, predictors of sperm production and semen quality were identified. In general, scrotal circumference (SC), scrotal shape score, scrotal neck perimeter, and testicular size (length, width and volume) increased (P < 0.05) with age. Although there were no significant differences among genetic groups for SC or testicular size, B. indicus bulls had the least pendulous scrotal shape, the shortest scrotal neck length, and the greatest scrotal neck perimeter (P < 0.05). Fat covering the TVC was thinner (P < 0.05) in bulls <= 36 months of age and in B. taunts bulls than in older bulls and B. indicus bulls, respectively. Age and genetic group did not affect testicular ultrasonic echotexture. B. indicus bulls tended (P < 0.1) to have the lowest average scrotal surface temperature (SST). In general, ejaculate volume, total number of spermatozoa and number of viable spermatozoa increased (P < 0.05) with age. However, there was no significant effect of age on sperm concentration, motility, major and total defects. The proportion of spermatozoa with minor defects was highest (P < 0.05) in bulls 37-60 months of age. B. indicus bulls had higher (P < 0.01) sperm concentration, total number of spermatozoa and number of viable spermatozoa than B. taunts bulls, with intermediate values for cross-bred bulls. Increased sperm production was associated with increased testicular volume, SC, TVC fat cover, and SST top-to-bottom gradient. Decreased semen quality was associated with increased SC and bottom SST, and decreased scrotal shape, scrotal neck perimeter and vascular cone diameter. In summary, age and genetic group affected the characteristics of the scrotum, testes, and TVC, sperm production and semen quality. In addition, characteristics of the scrotum, testes and TVC were associated with sperm production and semen quality in bulls and could be assessed for breeding soundness evaluation. (c) 2002 Elsevier B.V. All rights reserved.
Resumo:
Avaliaram-se os efeitos da progesterona (P4) sobre o crescimento folicular e na endocrinologia reprodutiva em ovelhas Bergamácia. Quatorze ovelhas sincronizadas com prostaglandinas (PGF2alfa ) foram distribuídas em dois grupos (n=7/grupo): grupo-controle e grupo tratado com progesterona (CIDR) depois da ovulação (dia zero). Desde o dia anterior à aplicação de PG até o dia 10, realizaram-se monitoramentos ultra-sonográficos para estabelecer o crescimento folicular. Amostras de sangue foram colhidas para a determinação de P4 desde o dia anterior à aplicação de PG até o dia 10 depois da ovulação. Para o perfil dos pulsos de hormônio luteinizante (LH), as colheitas de sangue ocorreram em intervalos de 30 minutos por um período de oito horas, nos dias um e seis. As taxas de crescimento diferiram (P<0,001) entre os grupos, 0,91±0,15 e 0,70±0,16mm/dia para os grupos controle e tratado, respectivamente. Os dias do platô dos animais controle e tratados foram de 1,9±0,72 e 2,9±0,45 (P<0,05), respectivamente. As concentrações médias de progesterona (P<0,001) foram diferentes entre os tratamentos. A freqüência dos pulsos diferiu no primeiro dia do ciclo (P<0,01), com valores de 2,55±0,09 pulsos/8 horas no grupo-controle e de 1,49±0,11 pulsos/8 horas no grupo tratado. No sexto dia, o grupo-controle 2,20±0,09 pulsos/8 horas apresentou maior número de pulsos (P<0,05) que o grupo tratado, 1,22±0,11 pulsos/8 horas. Os efeitos inibitórios da progesterona exógena no diâmetro do folículo dominante foram mediados pela redução na freqüência dos pulsos de LH.
Resumo:
The aim of this study was to evaluate the periapical healing after the use of membrane, bone graft, and mineral trioxide aggregate (MTA) in apical surgery of dogs' teeth. Apical lesions were induced in 48 roots of 6 dogs after coronal access and pulpal removal. Apical surgery consisted of osteotomy with trephine bur for the standardization of the critical surgical cavities, followed by apicoectomy, curettage, preparation of the root-end cavities with the aid of the ultrasonic device, and retrofilling with MTA. The surgical sites were divided into: group 1-filled with blood; group 2-filled with blood and recovered with membrane; group 3-filled with bone graft; and group 4-filled with bone graft and recovered with membrane. The results showed that the inflammatory infiltrate, the periapical healing process, and the behavior of MTA was the same in all groups, including the mineralization stimulation. It was concluded that the use of membranes and bone graft materials isolated or associated in apical surgery did not alter the periapical healing process after the root-end filling with MTA. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 309-314)
Resumo:
Purpose: To analyze the smear layer and the hybrid layer in noncarious and carious dentin prepared by different cutting instruments and restored with composite resin. Study design: Cavities were randomly prepared in 160 specimens (noncarious and artificial carious dentin) by high-speed diamond tips (KG Sorensen 1013), air abrasion system (Prepstart, Danville Engineering), ultrasonic tip (CVDentus 8.3231-1), and ultrasonic tip associated with ultrasonic cavitation by water for 10 s. Half of the cavities in each group were conditioned with 37% phosphoric acid for 15 s. The amount of smear layer and dentinal tubules present were analyzed using scanning electron microscopy and graded from 0 to 3. Cavities were prepared in another 20 noncarious specimens and 20 carious specimens and restored with adhesive composite resin system. The restorations were hemisected longitudinally and analyzed using scanning electron microscopy to evaluate the hybrid layer and resinous prolongation characteristics, using scores ranging from 1 to 6. Results: The data were statistically analyzed using Kruskal-Wallis and Dunn tests at 5% of significance level. There was evidence that the most efficient smear layer removal was the acid etching in the noncarious dentin and the water ultrasonic cavitation in the carious dentin. The hybrid layer formed on the noncarious and carious dentin prepared by the ultrasonic tip was more regular than in the specimens prepared by high-speed diamond tip, with many resinous prolongations. Conclusion: The ultrasonic tip seems to be a promising tool for carious dentin cavity preparation. Microsc. Res. Tech. 73:597-605, 2010. (C) 2009 Wiley-Liss, Inc.