151 resultados para Stimulus intensity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of the Problem: The effectiveness of low-intensity red laser for activating a bleaching gel and its effect in pulp temperature was not investigated in dental literature. Purpose: The objective of this study was to assess the effectiveness of low-intensity red laser for activating a bleaching gel, as well as its effect in temperature of the bleaching gel and the dental pulp. Materials and Methods: Forty extracted bovine teeth were immersed in a solution of coffee 14 days for darkening. The initial colors were recorded by spectrophotometric analysis. The specimens were randomly distributed into two groups (N = 20): the control, which did not receive light and the experimental group that received light from an appliance fitted with three red light-emitting laser diodes (? = 660 nm). A green-colored, 35% H2O2based bleaching gel was applied for 30 minutes, and changed three times. After bleaching, the colors were again measured to obtain the L*a*b* values. Color variation was calculated (?E) and the data submitted to the non-paired t-test (5%). To assess temperature, 10 human incisors were prepared, in which one thermocouple was placed on the bleaching gel applied on the surface of the teeth and another inside the pulp chamber. Results: There was a significant difference between the groups (p = 0.016), and the experimental group presented a significantly higher mean variation (7.21 +/- 2.76) in comparison with the control group (5.37 +/- 1.76). There was an increase in pulp temperature, but it was not sufficient to cause damage to the pulp. Conclusion: Bleaching gel activation with low-intensity red laser was capable of increasing the effectiveness of bleaching treatment and did not increase pulp temperature to levels deleterious to the pulp. CLINICAL SIGNIFICANCE The application of a low-intensity red laser was effective for activating a bleaching gel with green dye, without any deleterious increases in pulpal temperature. (J Esthet Restor Dent 24:126134, 2012)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Em parte das regiões onde se encontram as maiores áreas de algodão no Brasil atualmente, o índice pluviométrico está ao redor de 2.000 mm anuais, existindo risco de ocorrer lavagem do Cloreto de Mepiquat (CM) das folhas do algodoeiro antes de ser absorvido pelas plantas. O objetivo deste trabalho foi avaliar a lavagem do CM aplicado no algodoeiro por diferentes laminas de chuva simulada. Os tratamentos constaram de três doses do regulador à base de cloreto de mepiquat: 0, 15.0 e 30.0 g ha-1 e quatro lâminas de chuva simulada: 5, 10, 20 e 40 mm, mais um tratamento sem chuva. Foram utilizados vasos de 12 litros de capacidade e a cultivar Delta Opal. Os parâmetros avaliados foram: altura de plantas, número de ramos reprodutivos, massa de matéria seca, retenção de estruturas reprodutivas e área foliar. Quanto maior a intensidade de chuva ocorrida após a aplicação do regulador maior foi o comprometimento da ação do produto, que repercutiu em interferência no crescimento das plantas. Chuvas de 5.0 mm, ocorridas 90 minutos após a aplicação do cloreto de mepiquat, já causaram prejuízo na ação do produto no crescimento do algodoeiro, sendo o efeito maior com o aumento da quantidade de chuva simulada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: the aim of the present study was to evaluate the effect of low-intensity laser therapy on the wound healing process treated with steroid. Background Data: Various biological effects have been associated with low-level laser therapy (LLLT). Materials and Methods: Forty-eight rats were used, and after execution of a wound on the dorsal region of each animal, they were divided into 4 groups (n = 12), receiving the following treatments: G1 (control), wounds and animals received no treatment; G2, wounds were treated with LLLT; G3, animals received an intraperitoneal injection of steroid dosage (2 mg/kg of body weight); G4, animals received steroid and wounds were treated with LLLT. The laser emission device used was a GaAIAs (904 nm), in a contact mode, with 2.75 mW gated with 2.900 Hz during 120 sec (33 J/cm(2)). After the period of 3, 7, and 14 days, the animals were sacrificed and the parts sent to histological processing and dyed using hematoxylin and eosin (HE) and Masson trichromium (MT) techniques. Results: the results have shown that the wounds treated with steroid had a delay in healing, while LLLT accelerated the wound healing process. Also, wounds treated with laser in the animals treated with steroid presented a differentiated healing process with a larger collagen deposition and also a decrease in both the inflamatory infiltrated and the delay on the wound healing process. Conclusion: LLLT accelerated healing, caused by the steroid, acting as a biostimulative coadjutant agent, balancing the undesirable effects of cortisone (in the tissue healing process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light intensity preference of the pikeperch was tested in 1-m(2) tanks divided into four lateral compartments with a hole in the middle to allow the fish to move between compartments. Two experiments were carried out with both 0+ and 1+ pikeperch: one testing intensities from 25 to 300 lx and the other from 1 to 50 lx. Light preference was observed individually for 5 days at 8, 11, 14 and 17 h. on the first and fifth day, the preference was tested without differences in light intensity (control). In both experiments, both age groups showed preference for the lowest available light intensity. Preference for low light intensity in pikeperch may be related to innate activity and feeding behaviour and to avoidance of harmful effects of light. It is suggested that under aquaculture operations, pikeperch should be reared under very dim conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study was designed to determine the exercise intensity equivalent to the metabolic aerobic/anaerobic transition of alloxan diabetic rats, through lactate minimum test (LMT), and to evaluate the effects of swimming exercise at this intensity (LM) on the glucose and protein metabolism of these animals. Adult male Wistar rats received alloxan (SD, alloxan-injected rats that remained sedentary) intravenously (30 mg kg(-1) body weight) for diabetes induction. As controls (SC, vehicle-injected rats that remained sedentary), vehicle-injected rats were utilized. Two weeks later, the animals were submitted to oral glucose tolerance test (oGTT) and LMT. After the tests, some of the animals were submitted to swimming exercise training [TC (vehicle-injected rats that performed a 6-week exercise program) and TD (alloxan-injected rats that performed a 6-week exercise program)] for I h day(-1), 5 days week(-1), with an overload equivalent to LM determined by LMT, for 6 weeks. At the end of the experiment, the animals were submitted to a second LMT and oGTT, and blood and skeletal muscle assessments (protein synthesis and degradation in the isolated soleus muscle) were made. The overload equivalent to LM at the beginning of the experiment was lower in the SID group than in the SC group. After training, the overload equivalent to LM was higher in the TC and TD groups than in the SC and SD groups. The blood glucose of TD rats during oGTT was lower than that of SD rats. Protein degradation was higher in the SD group than in other groups. We conclude that LMT was sensitive to metabolic and physiologic alterations caused by uncontrolled diabetes. Training at LM intensity improved aerobic condition and the glucose and protein metabolism of alloxan diabetic rats. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pyroelectric sensors work as a thermal transducer converting the non-quantified thermal flux into the output measurable quantity of electrical charge, voltage or current. Ferroelectric ceramics and ferroelectric polymers have been extensively used as thermal detectors. More recently the research in the field of pyroelectricity has been concentrated on discovering materials with higher figures of merit (FOM), which means better sensing materials. Composite materials obtained with ferroelectric ceramics embedded in polymer host have received great attention because of their formability, mechanical resistance and the possibility to change their dielectric property varying the volume fraction of ceramic particles. In this work composite films made of modified lead titanate (PZ34) and poly(ether-ether-ketone) (PEEK) were characterized and used as sensing element to measure X-ray intensity in the ortovoltage range (120 - 300 kVp). The sensor response varies from 2.70 V to 0.80 V in the energy fluency range of 6.30 to 37.20 W/m(2). Furthermore the absorbed energy was analyzed as a function of the ionizing energy. The results indicate that the PZ34/PEEK composite with 60/40 vol.% can be useful to monitor X-ray radiation therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to examine the effects of high intensity exhaustive running exercise on the muscular torque capacity of the knee extensors for two types of contraction (concentric and eccentric) at different angular velocities (60 and 180 degrees/s) in well-trained runners. Eleven male runners specialized in middle and long-distance running volunteered to participate in this study. Initially each subject performed, on different days, two familiarization sessions on an isokinetic dynamometer and an incremental treadmill test to volitional exhaustion to determine the velocity associated with the onset of blood lactate accumulation (OBLA). The subjects then returned to the laboratory on two occasions, separated by at least seven days, to perform maximal isokinetic knee contractions at each of the velocities under eccentric (Ecc) and concentric (Con) conditions. Conducted randomly, one test was performed after a standardized warm-up period of 5 min at 50% VO2 max. The other test was performed 15 min after continuous running at OBLA until volitional exhaustion. Following this high intensity exercise there was a significant reduction of Con at 60 degrees/s and a significant reduction of Ecc at both velocities. Percent strength losses after running exercise were significantly different between contraction types only at 180 degrees/s. We can conclude that the reduction in isokinetic peak torque of the knee extensors after a session of high intensity exhaustive running exercise at OBLA depends on the contraction type and angular velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Social conflict between mice produces analgesia in the attacked mouse. Both the magnitude and type (opioid or nonopioid) of this analgesia have been related to attack intensity and strain of mouse. In the present study low intensity social conflict (7 bites) did not produce analgesia, whereas high intensity - 30 and 60 bites interactions produced, respectively, short-lasting (5 min) and very short-lasting (1 min) analgesia in Swiss albino mice, when compared with nonaggressive interaction (0 bite). The 30 bites aggressive interaction induced analgesia (AIIA) was not affected by IP injection of either naloxone (5.0 and 7.5 mg/kg) or diazepam (0.5, 1.0, 2.0 and 4.0 mg/kg). However, this attack-induced analgesia was reduced after IP administration of the 5-HT1A agonists, gepirone (0.3 and 3.0 mg/kg) and BAY R 1531 (0.01 mg/kg). These results indicate that the analgesia induced by 30 bites social conflict in Swiss albino mice does not involve opioid and GABA-benzodiazepine (GABA-BZD) mechanisms. In addition, they suggest that high-intensity social conflict activates serotonergic pain modulatory systems that act through 5-HT1A receptors. Copyright (C) 1997 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the effect of exercise mode on the blood lactate removal during recovery of high-intensity exercise. Nine male individuals performed the following tests in order to determine the blood lactate removal: Running - 2x200 m, the subjects ran at their maximum capacity, and rested 2 min between each bout. Swimming - 2x50 m, the subjects swam at their maximum capacity, and rested 2 min between each bout. Each test was realized on different days with three recovery modes: passive (sitting down), swimming, or running. Recovery exercise intensity was corresponding to the aerobic threshold. All recovery activities lasted 30 min. The two forms of active recovery were initiated 2 min after the end of high-intensity exercise and lasted 15 min, and were followed by 13 min of seated rest. After 1,7, 12,17, and 30 min of the end of high-intensity exercise, blood samples (25 mu l) were collected in order to determine the blood lactate concentration. By linear regression, between the logarithm of lactate concentration and its respective time of recovery, the half-time of blood lactate removal (t1/2) was determined. Time of high-intensity exercise and the lactate concentration obtained in the 1(st) min of recovery were not different between running and swimming. Passive recovery (PR) following running (R-PR=25.5+/-4.3 min) showed a t1/2 significantly higher than PR after swimming (S-PR=18.6+/-4.3 min). The t1/2 of the sequences running-running (R-R=13.0 min), running-swimming (R-S=12.9+/-3.8 min), swimming-swimming (S-S=13.2+/-2.8 min), and swimming-running (S-R=12.9+/-3.8 min) were significantly lower than the t1/2 of the R-PR and S-PR. There was no difference between the t1/2 of the sequences R-R R-S, and S-S. on the other hand the sequence S-R showed a t1/2 significantly lower than the sequences S-S and R-R. It was concluded that the two forms of active recovery determine an increase in the blood lactate removal, regardless of the mode of high-intensity exercise performed previously. Active recovery performed by the muscle groups that were not previously fatigued, can improve the blood lactate removal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A constant-current stimulator for high-impedance loads using only low-cost standard high-voltage components Is presented. A voltage-regulator powers an oscillator built across the primary of a step-up transformer whose secondary supplies, after rectification, the high voltage to a switched current-mirror in the driving stage. Adjusting the regulated voltage controls the pulsed-current intensity. A prototype produces stimulus of amplitude and pulsewidth within 0 less than or equal to I-skin less than or equal to 20 mA and 50 mus less than or equal to T-pulse less than or equal to 1 ms, respectively. Pulse-repetition spans from 1 Hz to 10 Hz. Worst case ripple is 3.7% at I-skin = 1 mA. Overall consumption is 5.6 W at I-skin = 20 mA.