92 resultados para Reproducibility of Results
Resumo:
Aims: To evaluate the reliability of fine needle aspirate cell blocks in the assessment of oestrogen receptor (ER), progesterone receptor (PR) and HER-2/neu proteins by immunohistochemistry in comparison with surgical specimens. Materials and methods: This is a retrospective study of 62 cases of breast carcinoma diagnosed by fine needle aspiration cytology (FNAC) and confirmed using the surgical specimen. Immunohistochemical tests were performed to assess the presence of oestrogen receptor (ER), progesterone receptor (PR) and HER-2/neu proteins in cell blocks and the corresponding surgical specimens. The cell block method used alcohol prior to formalin fixation. Cases with 10% or more stained cells were considered positive for ER and PR. Positivity for HER-2/neu was assessed on a scale of 0-3+. The criterion for positivity was a score of 3+. Results: Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the cell blocks in the investigation of ER, PR and HER-2/neu protein (3+) were (%): ER, 92.7, 85.7, 92.7, 85.7 and 90.3; PR, 92.7, 94.7, 97.4, 87.0 and 93.5; HER-2/neu, 70.0, 100.0, 100.0, 94.5 and 95.2. Discrepancies were seen in cell blocks in the 1+ and 2+ HER-2/neu staining scores: two of 12 cases scoring 2+ and one case of 26 scoring 1+ on cell blocks scored 3+ on surgical specimens. The correlation index between cell block and corresponding surgical specimen varied from 90% to 94%. Conclusion: Cell blocks provide a useful method of assessing ER, PR and HER-2/neu, mainly for inoperable and recurrent cases, but consideration should be given to carrying out FISH analysis on 1+ as well as 2+ HER-2/neu results. © 2012 Blackwell Publishing Ltd.
Resumo:
Background and Objective: Simple Measure of the Impact of Lupus Erythematosus in Youngsters (SMILEY) is a health-related quality of life (HRQOL) assessment tool for pediatric systemic lupus erythematosus (SLE), which has been translated into Portuguese for Brazil. We are reporting preliminary data on cross-cultural validation and reliability of SMILEY in Portuguese (Brazil). Methods: In this multi-center cross-sectional study, Brazilian children and adolescents 5-18 years of age with SLE and parents participated. Children and parents completed child and parent reports of Portuguese SMILEY and Portuguese Pediatric Quality of Life Inventory (PedsQLTM) Generic and Rheumatology modules. Parents also completed the Childhood Health Assessment Questionnaire (CHAQ). Physicians completed the SLE disease activity index (SLEDAI), Physician's Global Assessment of disease activity (PGA) and Systemic Lupus Erythematosus International Collaborating Clinics ACR Damage Index (SDI). Results: 99 subjects (84 girls) were enrolled; 93 children and 97 parents filled out the SMILEY scale. Subjects found SMILEY relevant and easy to understand and completed SMILEY in 5-15 minutes. Brazilian SMILEY was found to have good psychometric properties (validity and reliability), and the child-parent agreement was moderate. Conclusion: SMILEY may eventually be used routinely as a research/clinical tool in Brazil. It may be also adapted for other Portuguese-speaking nations offering critical information regarding the effect of SLE on HRQOL for children with SLE. © The Author(s), 2012.
Resumo:
Many epidemiological studies and clinical trials have been performed concerning actinic keratoses. The most eligible endpoint in the majority of articles is counting of actinic keratoses before and after treatments, nevertheless some authors support that this is not a reliable form of evaluation. The aim of this study was to evaluate the actinic keratoses counting by various raters and suggest approaches to increase the reliability. Cross-sectional study: forty-three patients were evaluated by four raters (inter- and intra-rater assessment) on the face and forearms. The mean actinic keratoses counts on the face and forearms were 7.7 and 9.1. The overall agreement among the raters for the facial and forearm actinic keratoses was 0.74 and 0.77. The intra-rater assessment showed high rates of agreement for the face (ICC = 0.93) and forearms (ICC = 0.83). Higher agreement occurred when counting up to five lesions. Four raters led to increased measurement variability and loss of reliability. Higher rates of agreement may be achieved with small number of lesions, limitation and/or segmentation of body areas to reduce their number, in AK prevention designs, are strategies that may lead to a greater reliability of these measurements. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
The aim of this study was to assess the validity and reliability of the Fonseca Anamnestic Index (IAF), used to assess the severity of temporomandibular disorders, applied to Brazilian women. We used a probabilistic sampling design. The participants were 700 women over 18 years of age, living in the city of Araraquara (SP). The IAF questionnaire was applied by telephone interviews. We conducted Confirmatory Factor Analysis (CFA) using Chi-Square Over Degrees of Freedom (χ2/df), Comparative Fit Index (CFI), Tucker-Lewis Index (TLI), and Root Mean Square Error of Approximation (RMSEA) as goodness of fit indices. We calculated the convergent validity, the average variance extracted (AVE) and the composite reliability (CR). Internal consistency was assessed by Cronbach's alpha coefficient (α).The factorial weights of questions 8 and 10 were below the adequate values. Thus, we refined the original model and these questions were excluded. The resulting factorial model showed appropriate goodness of fit to the sample (χ2/df = 3.319, CFI = 0.978, TLI = 0.967, RMSEA = 0.058). The convergent validity (AVE = 0.513, CR = 0.878) and internal consistency (α = 0.745) were adequate. The reduced IAF version showed adequate validity and reliability in a sample of Brazilian women.
Resumo:
The aim of this study was to investigate the reliability of visual and digital methods to assess marginal microleakage in vitro. Materials and Methods: Typical Class V preparations were made in bovine teeth and filled with composite resin. After dye penetration (0.5% basic fuchsin), teeth were sectioned and the 53 obtained fragments were assessed according to visual (stereomicroscope) and digital methods (Image Tool Software ® -ITS) (University of Texas Health Science Center-San Antonio Dental School, USA). Two calibrated examiners (A and B) evaluated dye penetration, by means of a stereomicroscope with ×20 magnification (scores), and by the ITS (millimeters). The intra- and inter-examiner agreement was estimated according to Kappa statistics (κ), and intraclass correlation coefficient (ρ). Results: In relation to the visual method, the intra-examiner agreement was almost perfect (κA = 0.87) and substantial (κB = 0.76), respectively to the examiner A and B. The inter-examiner agreement showed an almost perfect reliability (κ = 0.84). For the digital method, the intra-examiner agreement was almost perfect for both examiners and equal to ρ = 0.99, and so was the inter-examiner agreement value. Conclusion: Visual (stereomicroscope) and digital methods (ITS) showed high levels of intra- and inter-examiner reproducibility when marginal microleakage was assessed.
Resumo:
Although measurement errors can impair statistical analysis, reliability analysis has been neglected in applied microbiology. This study assessed the intra-rater reproducibility of the Agar-based method for estimation of phospholipase activity (Pz). Pz readings were performed twice by two examiners (E1, E2), either directly on plates or in photos, and both black and white backgrounds were used. Pz values were taken from one or triplicate colonies from each sample (n=30). Intra-examiner reproducibility was estimated using Intraclass Correlation Coefficient (ICC). For both examiners, reading triplicate (ICCE1=0.91, ICCE2=0.86) was better than one colony (ICCE1=0.86, ICCE2=0.80). E1 had an excellent concordance when measurements were performed on photos using a white background (ICC=0.95) and a good concordance in the other conditions
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Background: The aim of this study was to compare pelvic floor muscle (PFM) strength using transvaginal digital palpation in healthy continent women in different age groups, and to compare the inter- and intra-rater reliability of examiners performing anterior and posterior vaginal assessments.Methods: We prospectively studied 150 healthy multiparous women. They were distributed into four different groups, according to age range: G1 (n = 37), 30-40 years-old; G2 (n = 39), 41-50 years-old; G3 (n = 39), 51-60 years-old; and G4 (n = 35), older than 60 years-old. PFM strength was evaluated using transvaginal digital palpation in the anterior and posterior areas, by 3 different examiners, and graded using a 5-point Amaro's scale.Results: There was no statistical difference among the different age ranges, for each grade of PFM strength. There was good intra-rater concordance between anterior and posterior PFM assessment, being 64.7%, 63.3%, and 66.7% for examiners A, B, and C, respectively. The intra-rater concordance level was good for each examiner. However, the inter-rater reliability for two examiners varied from moderate to good.Conclusions: Age has no effect on PFM strength profiles, in multiparous continent women. There is good concordance between anterior and posterior vaginal PFM strength assessments, but only moderate to good inter-rater reliability of the measurements between two examiners.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Despite its high incidence, patellofemoral pain etiology remains unclear. No prior study has compared surface electromyography frequency domain parameters and surface electromyography time domain variables, which have been used as a classic analysis of patellofemoral pain. Thirty one women with patellofemoral pain and twenty eight pain-free women were recruited. Each participant was asked to descend a seven step staircase and data from five successful trials were collected. During the task, the vastus medialis and vastus lateralis muscle activities were monitored by surface electromyography. The data were processed and analyzed in four variables of the frequency domain (median frequency, low, medium and high frequency bands) and three time domain variables (Automatic, Cross-correlation and Visual Onset between the vastus medialis and vastus lateralis muscles). Reliability, Receiver Operating Characteristic curves and regression models were performed. The medium frequency band was the most reliable variable and different between the groups for both muscles, also demonstrated the best values of sensitivity and sensibility, 72% and 69% for the vastus medialis and 68% and 62% for the vastus lateralis, respectively. The frequency variables predicted the pain of individuals with patellofemoral pain, 26% for the vastus medialis and 20% for the vastus lateralis, being better than the time variables, which achieved only 7%. The frequency domain parameters presented greater reliability, diagnostic accuracy and capacity to predict pain than the time domain variables during stair descent and might be a useful tool to diagnose individuals with patellofemoral pain.
Resumo:
Stair ascent is an activity that exacerbates symptoms of individuals with patellofemoral pain. The discomfort associated with this activity usually results in gait modification such as reduced knee flexion in an attempt to reduce pain. Although such compensatory strategy is a logical approach to decrease pain, it also reduces the normal active shock absorption increasing loading rates and may lead to deleterious and degenerative changes of the knee joint. Thus, the aims of this study were (i) to investigate whether there is reduced knee flexion in adults with PFP compared to healthy controls; and (ii) to analyze loading rates in these subjects, during stair climbing. Twenty-nine individuals with patellofemoral pain and twenty-five control individuals (18-30years) participated in this study. Each subject underwent three-dimensional kinematic and kinetic analyses during stair climbing on two separate days. Between-groups analyses of variance were performed to identify differences in peak knee flexion and loading rates. Intraclass correlation coefficient was performed to verify the reliability of the variables. On both days, the patellofemoral pain group demonstrated significantly reduced peak knee flexion and increased loading rates. In addition, the two variables obtained high to very high reliability. Reduced knee flexion during stair climbing as a strategy to avoid anterior knee pain does not seem to be healthy for lower limb mechanical distributions. Repeated loading at higher loading rates may be damaging to lower limb joints.
Resumo:
A montmorillonite from Wyoming-USA was used to prepare an organo-clay complex, named 2-thiazoline-2-thiol-hexadecyltrimethylammonium-clay (TZT-HDTA-clay), for the purpose of the selective adsorption of the heavy metals ions and possible use as a chemically modified carbon paste electrode (CMCPE). Adsorption isotherms of Hg 2+, Pb 2+, Cd 2+, Cu 2+, and Zn 2+ from aqueous solutions as a function of the pH were studied at 298 K. Conditions for quantitative retention and elution were established for each metal by batch and column methods. The organo-clay complex was very selective to Hg(II) in aqueous solution in which other metals and ions were also present. The accumulation voltammetry of Hg(II) was studied at a carbon paste electrode chemically modified with this material. The mercury response was evaluated with respect to the pH, electrode composition, preconcentration time, mercury concentration, cleaning solution, possible interferences and other variables. A carbon paste electrode modified by TZT-HDTA-clay showed two peaks: one cathodic peak at about 0.0 V and an anodic peak at 0.25 V, scanning the potential from -0.2 to 0.8 V (0.05 M KNO 3 vs. Ag/AgCl). The anodic peak at 0.25 V presents excellent selectivity for Hg(II) ions in the presence of foreign ions. The detection limit was estimated as 0.1 μg L -1. The precision of determination was satisfactory for the respective concentration level. 2005 © The Japan Society for Analytical Chemistry.
Resumo:
The aim of this study was to analyze the reproducibility of the electromyography signal's parameters (EMG) in the frequency domain used in the characterization of localized muscle fatigue. Fifteen male subjects underwent a fatigue test based on isometric knee extension, being held at three different times at intervals of seven days. To assess the reproducibility of data between the tests we calculated the correlation coefficient (ICC) for the median frequency (MF) in total exercise time (MFT), MF obtained for every 10% of exercise time (MF10%) and the powers of the frequency bands obtained by dividing the power spectrum at windows of 20 Hz. The results showed: (1) excellent reproducibility for MFT, (2) good reproducibility for MF10%, and (3) greater variation in the signal EMG bands from 20 to 120 Hz, especially at the bands of 20-40 Hz and 40-60 Hz, which showed greater sensitivity to the process of muscle fatigue. We conclude that the MF is a variable that shows good reproducibility and that the fragmented analysis of the power spectrum, by means of frequency bands, showed that significant variations occur in the EMG signal during the installation of the fatigue process, having potential to become a new method for the characterization of localized muscle fatigue.
Resumo:
OBJETIVO: Estudar a confiabilidade, da versão em português, do questionário para o diagnóstico psicológico e psicossocial dos indivíduos com desordens temporomandibulares (RDC/TMD). MÉTODOS: Foram entrevistados 109 indivíduos, de ambos sexos, que demandaram atendimento junto à Clínica de Fisioterapia do Centro Universitário de Araraquara, de janeiro a julho de 2006. Os questionários foram aplicados por um único examinador. Após duas semanas, o mesmo foi reaplicado em 36 indivíduos. Para avaliação da consistência interna do método, utilizou-se o Coeficiente Alfa de Cronbach; para análise da reprodutibilidade intra-examinador, o Coeficiente de Correlação Intraclasse (ro) e a estatística Kappa (kapa), respectivamente às variáveis de natureza quantitativa e qualitativa. RESULTADOS: A consistência interna para as dimensões intensidade da dor crônica e incapacidade; limitação da função mandibular; sintomas físicos não-específicos, incluindo os itens de dor; sintomas físicos não-específicos, excluindo os itens de dor e depressão foi de 0,8479, 0,8971, 0,8673, 0,8080 e 0,9270 respectivamente, atestando ao método excelente validade interna. Obteve-se excelente concordância intra-examinador para as questões referentes ao tempo de presença da dor e sua gradação, e boa para a questão referente à dor presente. Os menores valores de kapa relacionaram-se aos itens de sintomas físicos e depressão. A percepção de estalos ou rangidos pelos indivíduos apresentou concordância regular bem como a questão referente à procura de profissional para tratamento da dor. As demais questões apresentaram reprodutibilidade boa e ótima, sendo que a maioria dessas apresentou nível máximo de concordância. CONCLUSÃO: A versão adaptada para o português mostrou-se confiável para detecção das alterações psicológicas e psicossociais associadas às desordens temporomandibulares.