147 resultados para Reactors


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Toxoplasmosis is a zoonosis caused by Toxoplasma gondii, a coccidian protozoan of worldwide distribution. The seroprevalence in canine population can be an alternative for measuring T. gondii urban spreading. A total of 780 blood samples from dogs were collected, during the yearly anti-rabies campaign, carried out by the Department of Veterinary Hygiene and Public Health, School of Veterinary Medicine and Animal Husbandry (FMVZ), São Paulo State University, UNESP, together with the county health authorities, in August 1999. Using Indirect Fluorescent Antibody Test (IFAT) for detecting antibodies anti-T. gondii in the sera samples, we observed that 258 dogs (33.1%) were positive. The associations between the serological results and the epidemiological variables were studied. Statistically significant differences were not found regarding sex (32.2% male and 34.3% female reactors). Dogs without a defined breed showed seropositivity statistically higher than the pedigreed group. The occurrence of infection was considered higher with age.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The performances of two anaerobic sequencing batch reactors (1.2 m 3) containing biomass immobilized in inert support and as granular sludge in the treatment of domestic sewage from the Campus of São Carlos-University of São Paulo were evaluated. The experimental phase lasted seventy days. During this period, the reactors presented quite similar performances in respect to COD and total suspended solids removal, achieving average efficiencies of approximately 60% and 75%, respectively. The analysis using molecular biology techniques on biomass samples taken at 35 th and 70 th showed differences in the bacterial community in the reactors indicating that the type of biomass immobilization selected the populations differently. A higher similarity was found for the Archaea domain probably because these microorganisms utilize specific substrates formed at the end of the anaerobic process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a dedicated algorithm for lation of single line-to-ground faults in distribution systems. The proposed algorithm uses voltage and current phasors measured at the substation level, voltage magnitudes measured at some buses of the feeder, a database containing electrical, operational and topological parameters of the distribution networks, and fault simulation. Voltage measurements can be obtained using power quality devices already installed on the feeders or using voltage measurement devices dedicated for fault location. Using the proposed algorithm, likely faulted points that are located on feeder laterals geographically far from the actual faulted point are excluded from the results. Assessment of the algorithm efficiency was carried out using a 238 buses real-life distribution feeder. The results show that the proposed algorithm is robust for performing fast and efficient fault location for sustained single line-to-ground faults requiring less than 5% of the feeder buses to be covered by voltage measurement devices. © 2006 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study it is reported the operation of a horizontalflow anaerobic immobilized biomass (HAlB) reactor under sulfate-reducing condition which was also exposed to different amounts of ethanol and benzene. The HAIB reactor comprised of an immobilized biomass on polyurethane foam and ferrous and sodium sulfate solutions were used (91 and 550 mg.l -1, respectively), to promote a sulfate-reducing environment. Benzene was added at an initial concentration of 2.0 mg.l -1 followed by an increased to 9 e 10 mg. l -1, respectively. Ethanol was added at an initial concentration of 170 mg.l -1 followed by an increased range of 960 mg.l -1. The reactor was operated at 30 (± 2) °C with hydraulic detention time of 12 h. Organic matter removal efficiency of 90% with a maximum benzene degradation rate of 0.07 mv, benzene.mg -1 vss.d -1 Thus, this work corroborate the data obtained for Cattony et al (2005) and also demonstrate that compact units of HAIB reactors, under sulfate reducing conditions, are a potential alternative for in situ aromatic compounds bioremediation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, the efficiency of two-stage upflow anaerobic sludge blanket (UASB) reactors was evaluated in bench scale, for treating a liquid effluent from coffee pulping. Hydraulic detention times (HDT) were 4.0; 5.2 and 6.2 days, resulting in organic loading rates (OLR) of 5.8; 3.6 and 3.0g total COD per (L-d) in the first reactor (Rl) and HDT of 2.0; 2.6 and 3.1 days with OLR of 5.8; 0.5 and 0.4 g total COD per (L-d) in the second reactor (R2). The medium values of total COD affluent varied from 15.440 to 23.040 mg O 2/L, and in the effluent to the reactors 1 and 2 were from l.lOO to 11.500 mg 0 2/L and 420 to 9.000 mg O 2/L, respectively. The medium values of removal efficiencies of total COD and TSS varied from 66 to 98% and 93 to 97%, respectively, in the system of treatment with the UASB reactors, in two stages. The content of methane in the biogas varied from 69 to 89% in the Rl and from 52 to 73% in the R2. The maximum volumetric methane production of 0.483 m 3 CH 4per (m 3 reactor d) was obtained with OLR of 3.6 g total COD per (L reactor d) and HDT of 6.2 days in the Rl. The volatile fatty acids concentration was kept below 100mg/L with HDT of 5.2 and 6.2 days in the Rl and HDT of 2.6 and 3.1 days in the R2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aerobic internal-loop reactors use active biomass attached in a supporting media (biofilm) with the advantage of retaining a big biomass concentration in a small physical space, removing carbonaceous matter and nitrogen in only one reactor. Liquid circulation occurs due to hydrostatic pressure difference produced by air injection in the riser. In biphasic conditions liquid circulation velocities, gas holdup and oxygen transfer coefficient in four different reactor configurations were studied. For the three-phase conditions, the same parameters in just one of those configurations were evaluated. Also, there were three granular supporting media characterized. On the other hand, the relationship between internal and external tube areas and supporting media concentrations influence the liquid velocity, gas holdup and oxygen mass transfer values and some important supporting media characteristics were observed and compared.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a non-linear symplectic map that describes the alterations of the magnetic field lines inside the tokamak plasma due to the presence of a robust torus (RT) at the plasma edge. This RT prevents the magnetic field lines from reaching the tokamak wall and reduces, in its vicinity, the islands and invariant curve destruction due to resonant perturbations. The map describes the equilibrium magnetic field lines perturbed by resonances created by ergodic magnetic limiters (EMLs). We present the results obtained for twist and non-twist mappings derived for monotonic and non-monotonic plasma current density radial profiles, respectively. Our results indicate that the RT implementation would decrease the field line transport at the tokamak plasma edge. © 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a distribution feeder simulation using VHDL-AMS, considering the standard IEEE 13 node test feeder admitted as an example. In an electronic spreadsheet all calculations are performed in order to develop the modeling in VHDL-AMS. The simulation results are compared in relation to the results from the well knowing MatLab/Simulink environment, in order to verify the feasibility of the VHDL-AMS modeling for a standard electrical distribution feeder, using the software SystemVision™. This paper aims to present the first major developments for a future Real-Time Digital Simulator applied to Electrical Power Distribution Systems. © 2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents an efficient tabu search algorithm (TSA) to solve the problem of feeder reconfiguration of distribution systems. The main characteristics that make the proposed TSA particularly efficient are a) the way in which the neighborhood of the current solution was defined; b) the way in which the objective function value was estimated; and c) the reduction of the neighborhood using heuristic criteria. Four electrical systems, described in detail in the specialized literature, were used to test the proposed TSA. The result demonstrate that it is computationally very fast and finds the best solutions known in the specialized literature. © 2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sugarcane bagasse was pretreated with ozone to increase lignocellulosic material digestibility. Bagasse was ozonated in a fixed bed reactor at room temperature, and the effect of the two major parameters, ozone concentration and sample moisture, was studied. Acid insoluble and total lignin decreased whereas acid soluble lignin increased in all experiments. Pretreatment barely attacked carbohydrates, with cellulose and xylan recovery rates being >92%. Ozonolysis increased fermentable carbohydrate release considerably during enzymatic hydrolysis. Glucose and xylose yields increased from 6.64% and 2.05%, for raw bagasse, to 41.79% and 52.44% under the best experimental conditions. Only xylitol, lactic, formic and acetic acid degradation compounds were found, with neither furfural nor HMF (5-hydroxymethylfurfural) being detected. Washing detoxification provided inhibitor removal percentages above 85%, increasing glucose hydrolysis, but decreasing xylose yield by xylan solubilization. SEM analysis showed structural changes after ozonization and washing. © 2013 Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aromatic amines are environmental pollutants and represent one of the most important classes of industrial and natural chemicals. Some types of complex effluents containing these chemical species, mainly those originated from chemicals plants are not fully efficiently treated by conventional processes. In this work, the use of electrochemical technology through an electrolytic pilot scale flow reactor is considered for treatment of wastewater of a chemical industry manufacturer of antioxidant and anti-ozonant substances used in rubber. Experimental results showed that was possible to remove between 65% and 95% of apparent colour and chemical oxygen demand removal between 30 and 90% in 60 min of treatment, with energy consumption rate from 26 kWh m-3 to 31 kWh m-3. Absorbance, total organic carbon and toxicity analyses resulted in no formation of toxic by-products. The results suggest that the presented electrochemical process is a suitable method for treating this type of wastewater, mainly when pre-treated by aeration. Copyright © 2013 Inderscience Enterprises Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anaerobic digestion applied to stillage usually results in treatment performances. However, effluents from anaerobic reactors still present a residual polluting load due to the presence of organic recalcitrant compounds. Additional treatment methods, such as coagulation-flocculation, may be utilized to improve the final effluent quality. In this study, we assessed the processes of coagulation and flocculation for sugarcane stillage samples previously submitted to anaerobic digestion, aiming to obtain optimal conditions for the physicochemical treatment. Natural corn starch and ferric chloride were tested as coagulants. While starch was considered as not suitable for the treatment for the tested conditions, ferric chloride assays presented satisfactory results. The investigated parameters included coagulant solution dose, rapid mixing gradient and time, flocculation gradient and time, and sedimentation time. Their adjusted values at which better performances obtained were, respectively, 1.6 g L-1, 325 rpm, 10 s, 65 rpm, 20 and 20 min. The best color, turbidity, and chemical oxygen demand removal efficiencies were 95, 97, and 65%, respectively. Stillage pH variation to alkaline conditions did not result in improved removal efficiencies. Although relatively high removal efficiencies of constituents were obtained, the final effluent characteristics did not fit regulations of water reuse in the agriculture through fertigation. However, stillage can definitely become more easily managed if better final effluent quality control parameters are achieved, enabling for example effluents discharge in water bodies. © 2013 Copyright Balaban Desalination Publications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The updraft biomass gasifiers currently available produce a gas with high tar content. For almost all downstream applications a substantial reduction of the tar concentration is required. The gravimetric tar concentration behavior in producer gas, obtained at a modified updraft fixed bed gasifier, was studied. The feedstock feeding system was modified respect to the traditional updraft gasification design in order to decrease the tar concentration in the producer gas; the material is feeding continuously through a conduit in the base of the reactor over the grate. The caloric power of the syngas obtained was slightly lower than the typical value for this type of reactor and the highest efficiency obtained for the woodchip gasification was 77%. The highest tar concentration obtained during the experiments was 1652.7 mg N m-3 during the first our of experiments, comparable with the smaller value reported for the updraft reactors, this value is reduced significantly after the stabilization of the gasification process in the reactor. The smaller value obtained was 21 mg N m-3. © 2013 Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the ethanol addition as a strategy for start-up and acclimation of a pilot scale (1300 L) anaerobic sequencing batch biofilm reactor (AnSBBR) for the treatment of municipal landfill leachate with seasonal biodegradability variations. The treatment was carried out at ambient temperature (23.8 ± 2.1 °C) in the landfill area. In a first attempt, the leachate collected directly from landfill showed to be predominantly recalcitrant to anaerobic treatment and the acclimation was not possible. In a second attempt, adding ethanol to leachate, the reactor was successfully acclimated. After acclimation, without ethanol addition, the CODTotal influent ranged from 4970 to 13040 mg L-1 and the removal efficiencies ranged from 12.1% to 70.7%. A final test was carried out increasing the ammonia and free-ammonia concentration from 2486 mgN L-1 and 184 mgN L-1 to 4519 mgN L-1 and 634 mgN L-1, respectively, with no expressive inhibition verified. The start-up strategy was found to be feasible, providing the acclimation of the biomass in the AnSBBR, and maintaining the biomass active even when the leachate was recalcitrant. © 2013 Elsevier Ltd. All rights reserved.