53 resultados para RELATIVE FREQUENCY


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Objectives. A frequent mutation in the cystathionine beta-synthase (CBS) gene (844ins68, a 68-bp insertion in the coding region of exon 8) was recently discovered. In the present study we Investigated this mutation as a candidate risk factor for venous thrombosis.Design and Methods. The prevalence of the 844ins68 CBS mutation was determined in 101 patients with objectively diagnosed deep venous thrombosis and in 101 healthy controls matched for age, sex and race. PCR amplification of a DNA fragment containing exon 8 of the CBS gene was employed to determine the genotypes, Additionally, Bsrl restriction enzyme digestion of the PCR products was performed in all samples from carriers of the insertion, to test for concurrent presence of a second mutation (T833C) in the CBS gene.Results. The insertion was found in 21 out of 101 patients (20.8%; allele frequency 0.109) and in 20 out of 101 controls (19.8%; allele frequency 0.114), yielding a relative risk for venous thrombosis related to the 844ins68 CBS mutation close to 1.0. In addition, the T833C GBS mutation was detected in all alleles carrying the 844ins68 CBS insertion, confirming the co-inheritance of the two mutations.Interpretation and Conclusions. Our findings do not support the hypothesis that the 844ins68 mutation in the CBS gene is a genetic risk factor for venous thrombosis. (C)1998, Ferrata Storti Foundation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the IR absorption spectrum of 13CH3OH around the frequency of the 10R(20) CO2 laser line. We found two absorption lines which can be excited by 10R(20) and studied the FIR laser emissions excited by this pump line using a waveguide CO2 laser of 300 MHz tunability. We report two new FIR laser lines of large offset, not previously observed due to their weakness and closeness to other stronger lines. We measured the frequencies of five FIR laser lines for the first time by an accurate heterodyne technique and present the complete assignments of the IR-FIR laser systems relative to this pump line. Furthermore we present new frequency values for two FIR laser lines whose frequencies had been previously wrongly measured. Copyright © 1997 Elsevier Science Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Objectives. A frequent mutation in the cystathionine β- synthase (CBS) gene (844ins68, a 68-bp insertion in the coding region of exon 8) was recently discovered. In the present study we investigated this mutation as a candidate risk factor for venous thrombosis. Design and Methods. The prevalence of the 844ins68 CBS mutation was determined in 101 patients with objectively diagnosed deep venous thrombosis and in 101 healthy controls matched for age, sex and race. PCR amplification of a DNA fragment containing exon 8 of the CBS gene was employed to determine the genotypes. Additionally, Bsrl restriction enzyme digestion of the PCR products was performed in all samples from carriers of the insertion, to test for concurrent presence of a second mutation (T833C) in the CBS gene. Results. The insertion was found in 21 out of 101 patients (20.8%; allele frequency 0.109) and in 20 out of 101 controls (19.8%; allele frequency 0.114), yielding a relative risk for venous thrombosis related to the 844ins68 CBS mutation close to 1.0. In addition, the T833C CBS mutation was detected in all alleles carrying the 844ins68 CBS insertion, confirming the co- inheritance of the two mutations. Interpretation and Conclusions. Our findings do not support the hypothesis that the 844ins68 mutation in the CBS gene is a genetic risk factor for venous thrombosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The GPS observables are subject to several errors. Among them, the systematic ones have great impact, because they degrade the accuracy of the accomplished positioning. These errors are those related, mainly, to GPS satellites orbits, multipath and atmospheric effects. Lately, a method has been suggested to mitigate these errors: the semiparametric model and the penalised least squares technique (PLS). In this method, the errors are modeled as functions varying smoothly in time. It is like to change the stochastic model, in which the errors functions are incorporated, the results obtained are similar to those in which the functional model is changed. As a result, the ambiguities and the station coordinates are estimated with better reliability and accuracy than the conventional least square method (CLS). In general, the solution requires a shorter data interval, minimizing costs. The method performance was analyzed in two experiments, using data from single frequency receivers. The first one was accomplished with a short baseline, where the main error was the multipath. In the second experiment, a baseline of 102 km was used. In this case, the predominant errors were due to the ionosphere and troposphere refraction. In the first experiment, using 5 minutes of data collection, the largest coordinates discrepancies in relation to the ground truth reached 1.6 cm and 3.3 cm in h coordinate for PLS and the CLS, respectively, in the second one, also using 5 minutes of data, the discrepancies were 27 cm in h for the PLS and 175 cm in h for the CLS. In these tests, it was also possible to verify a considerable improvement in the ambiguities resolution using the PLS in relation to the CLS, with a reduced data collection time interval. © Springer-Verlag Berlin Heidelberg 2007.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low-frequency multipath is still one of the major challenges for high precision GPS relative positioning. In kinematic applications, mainly, due to geometry changes, the low-frequency multipath is difficult to be removed or modeled. Spectral analysis has a powerful technique to analyze this kind of non-stationary signals: the wavelet transform. However, some processes and specific ways of processing are necessary to work together in order to detect and efficiently mitigate low-frequency multipath. In this paper, these processes are discussed. Some experiments were carried out in a kinematic mode with a controlled and known vehicle movement. The data were collected in the presence of a reflector surface placed close to the vehicle to cause, mainly, low-frequency multipath. From theanalyses realized, the results in terms of double difference residuals and statistical tests showed that the proposed methodology is very efficient to detect and mitigate low-frequency multipath effects. © 2008 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To ensure high accuracy results from GPS relative positioning, the multipath effects have to be mitigated. Although the careful selection of antenna site and the use of especial antennas and receivers can minimize multipath, it cannot always be eliminated and frequently the residual multipath disturbance remains as the major error in GPS results. The high-frequency multipath from large delays can be attenuated by double difference (DD) denoising methods. But the low-frequency multipath from short delays is very difficult to be reduced or modeled. In this paper, it is proposed a method based on wavelet regression (WR), which can effectively detect and reduce the low-frequency multipath. The wavelet technique is firstly applied to decompose the DD residuals into the low-frequency bias and high-frequency noise components. The extracted bias components by WR are then directly applied to the DD observations to correct them from the trend. The remaining terms, largely characterized by the high-frequency measurement noise, are expected to give the best linear unbiased solutions from a least-squares (LS) adjustment. An experiment was carried out using objects placed close to the receiver antenna to cause, mainly, low-frequency multipath. The data were collected for two days to verify the multipath repeatability. The ground truth coordinates were computed with data collected in the absence of the reflector objects. The coordinates and ambiguity solution were compared with and without the multipath mitigation using WR. After mitigating the multipath, ambiguity resolution became more reliable and the coordinates were more accurate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A previous work showed that viscosity values measured high frequency by ultrasound agreed with the values at low frequency by the rotational viscometer when conditions are met, such as relatively low frequency viscosity. However, these conditions strongly reduce the range of the measurement cell. In order to obtain a measurement range and sensitivity high frequency must used, but it causes a frequency-dependent decrease on the viscosity values. This work introduces a new simple in order to represent this frequency-dependent behavior.model is based on the Maxwell model for viscoelastic , but using a variable parameter. This parameter has physical meaning because it represents the linear behavior the apparent elasticity measured along with the viscosity by .Automotive oils SAE 90 and SAE 250 at 22.5±0.5oC viscosities at low frequency of 0.6 and 6.7 Pa.s, respectively,tested in the range of 1-5 MHz. The model was used in to fit the obtained data using an algorithm of non-linear in Matlab. By including the viscosity at low frequency an unknown fitting parameter, it is possible to extrapolate its . Relative deviations between the values measured by the and extrapolated using the model for the SAE 90 and SAE 250 oils were 5.0% and 15.7%, respectively.©2008 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A three-laser heterodyne system was used to measure the frequencies of twelve optically pumped laser emissions from 13CH3OH in the far-infrared (FIR) region. These emissions, ranging from 54 to 142 μm, are reported with fractional uncertainties up to ±2 × 10-7 along with their polarization relative to the CO2 pump. Using the 9P32 and 10R14 CO2 lines, complete spectroscopic assignments for two laser systems were confirmed.