186 resultados para Quartz microstructures


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the influence of light-curing units (LCUs) on Knoop microhardness (KHN) of different composite resins formulations. Four LCUs, one Quartz-Tungsten-Halogen (QTH) for 20 s, one Argon-Ion-Laser (AL) for 10 s, one Plasma-Arc-Curing (PAC) for 9 s, and one Light-Emitting-Diode (LED) for 20 s, and three composite resins, nanofill and easy cure (Filtek (TM) Supreme), microhybrid and medium cure (Herculite XRV), and microfill and difficult cure (Heliomolar) were used. Discs (4 x 2 mm(2)) of each composite resin were divided in 12 Groups and KHN was measured at the top (T) and bottom (B) surfaces. Data were analyzed using two-way ANOVA and Tukey's test (p < 0.05). Top presented significantly higher KHN than bottom surface for all composite resins and LCUs tested. Statistical significant differences were observed among the LCUs. At the bottom surface QTH and LED presented higher KHN than PAC and LA. However, at the top surface PAC and LA presented similar results than QTH for nanofill and microhybrid composite resins. Different LCUs play an important effect on Knoop microhardness and the composite resin formulations were significant factor on the photosensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). Material and methods: Filtek (TM) Z350 nanofilled composite resins and Amelogen (R) Plus, Vit-l-escence (TM) and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free Light (TM) 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm(-1)) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). Results: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey's test showed that the nanofilled resin (Filtek (TM) Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (Filtek (TM) Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free Light (TM) 2). Conclusions: The nanofilled resin showed the lowest DC, and the Vit-l-escence (TM) microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Epiphany (TM) Sealer is a new dual-curing resin-based sealer and has been introduced as an alternative to gutta-percha and traditional root canal sealers. The canal filling is claimed to create a seal with the dentinal tubules within the root canal system producing a 'monoblock' effect between the sealer and dentinal tubules. Therefore, considering the possibility to incorporate the others adhesive systems, it is important to study the bond strength of the resulting cement. Forty-eight root mandibular canines were sectioned 8-mm below CEJ. The dentine discs were prepared using a tapered diamond bur and irrigated with 1% NaOCl and 17% EDTA. Previous the application Epiphany (TM) Sealer, the Epiphany (TM) Primer, AdheSE, and One Up Bond F were applied to the root canal walls. The LED and QTH (Quartz Tungsten Halogen) were used to photo-activation during 45 s with power density of 400 and 720 mW/cm(2), respectively. The specimens were performed on a universal testing machine at a cross-head speed of 1 mm/min until bond failure occurred. The force was recorded and the debonding values were used to calculate Push-out bond strength. The analysis of variance (ANOVA) and Tukey's post-hoc tests showed significant statistical differences (P < 0.05) to Epiphany (TM) Sealer/Epiphany (TM) Primer/QTH and EpiphanyTM Sealer/AdheSE/QTH, which had the highest mean values of bond strength. The efficiency of resin-based filling materials are dependent the type of light curing unit used including the power density, the polymerization characteristics of these resin-based filling materials, depending on the primer/adhesive used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of cyclical mechanical loading on the bond strength of a fiber and a zirconia post bonded to root dentin.Materials and Methods: Forty single-rooted human teeth (maxillary incisors and canines) were sectioned, and the root canals were prepared at 12 mm. Twenty randomly seleced specimens received a quartz fiber post (FRC) (D.T. Light-Post) and 20 others received a zirconia post (ZR) (Cosmopost). The posts were resin luted (All Bond 2 + resin cement Duo-link) and each specimen was embedded in epoxy resin inside a PVC cylinder. Ten specimens with FRC post and 10 specimens with ZR post were submitted to fatigue testing (2,000,000 cycles; load: 50 N; angle of 45 degrees; frequency: 8 Hz), while the other 20 specimens were not fatigued. Thus, 4 groups were formed: G1: FRC+O cycles; G2: FRC+2,000,000 cycles; G3: ZR+O cycles; G4: ZR+2,000,000 cycles. Later, the specimens were cut perpendicular to their long axis to form 2-mm-thick disk-shaped samples (4 sections/specimen), which were submitted to the push-out test (1 mm/min). The mean bond strength values (MPa) were calculated for each tooth (n = 10) and data were submitted to statistical analysis (alpha = 0.05).Results: Two-way ANOVA revealed that the bond strength was significantly affected by mechanical cycling (p = 0.0014) and root post (p = 0.0325). The interaction was also statistically significant (p = 0.0010). Tukey's test showed that the mechanical cycling did not affect the bonding of FRC to root dentin, while fatigue impaired the bonding of zirconium to root dentin.Conclusion: (1) the bond strength of the FRC post to root dentin was not reduced after fatigue testing, whereas the bonding of the zirconia post was significantly affected by the fatigue. (2) Cyclical mechanical loading appears to damage the bond strength of the rigid post only.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This study evaluated the surface hardness of a resin cement (RelyX ARC) photoactivated through indirect composite resin (Cristobal) disks of different thicknesses using either a light- emitting diode (LED) or quartz tungsten halogen (QTH) light source. Material and Methods: Eighteen resin cement specimens were prepared and divided into 6 groups according to the type of curing unit and the thickness of resin disks interposed between the cement surface and light source. Three indentations (50 g for 15 s) were performed on the top and bottom surface of each specimen and a mean Vickers hardness number (VHN) was calculated for each specimen. The data were analyzed using two-way ANOVA and Tukey-Kramer test was used for post-hoc pairwise comparisons. Results: Increased indirect resin disk thickness resulted in decreased mean VHN values. Mean VHN values for the top surfaces of the resin cement specimens ranged from 23.2 to 46.1 (QTH) and 32.3 to 41.7 (LED). The LED curing light source produced higher hardness values compared to the QTH light source for 2- and 3-mm-thick indirect resin disks. The differences were clinically, but not statistically significant. Increased indirect resin disk thickness also resulted in decreased mean VHN values for the bottom surfaces of the resin cement: 5.8 to 19.1 (QTH) and 7.5 to 32.0 (LED). For the bottom surfaces, a statistically significant interaction was also found between the type of curing light source and the indirect resin disk thickness. Conclusions: Mean surface hardness values of resin cement specimens decreased with the increase of indirect resin disk thickness. The LED curing light source generally produced higher surface hardness values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Bura do Itapira pua carbonatite is located in southern Brazil and belongs to the Cretaceous Ponta Grossa alkaline-carbonatitic province related to the opening of the South Atlantic. The carbonatite complex is emplaced in Proterozoic granites and is mainly composed of plutonic magnesio- to ferrocarbonatite, with smaller amounts of subvolcanic magnesiocarbonatite. Hydrothermal alteration of the carbonatite has led to the formation of quartz, apatite, fluorite, rue earth fluorocarbonates, barite and sulfides in variable proportions. Trace element data, delta(13)C and delta(18)O are presented here, with the aim of better understanding the geochemical nature of hydrothermal alteration related to rare earth elements (REE) mineralization. The non-overprinted plutonic carbonatite shows the lowest REE contents, and its primitive carbon and oxygen stable isotopic composition places it in the field of primary igneous carbonatites. Two types of hydrothermally overprinted plutonic carbonatites can be distinguished based on secondary minerals and geochemical composition. Type I contains mainly quartz, rare earth fluorocarbonates and apatite as hydrothermal secondary minerals, and has steep chondrite normalized REE patterns, with Sigma(REE+Y) of up to 3 wt.% (i.e., two orders of magnitude higher than in fresh plutonic samples). In contrast, the Type II overprint contains apatite, fluorite and barite as dominant hydrothermal minerals, and is characterized by heavy REE enrichment relative to the fresh samples, with flat chondrite normalized REE patterns. Carbon and oxygen stable isotope ratios of Types I and II are elevated (delta(18)O + 8 to + 12 parts per thousand; delta(13)C - 6 to - 2 parts per thousand) relative to the fresh samples. Hydrothermally overprinted carbonatites exposed to weathering show even higher delta(18)O values (delta(18)O 13 to 25 parts per thousand) but no additional REE enrichment. The subvolcanic carbonatite has anomalously high delta(13)C of up to + 1 parts per thousand, which suggests crustal contamination through interaction with carbonate-bearing metasediments. (C) 1999 Elsevier B.V. B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Pluriserial Ribeira Magmatic System-590 of the Late Precambrian Ribeira Fold Belt comprises seven groups of high-K rocks of crustal or mantle origin with ages ranging between 620 and 570 Ma. One of these groups is represented by transalkaline suites akin to appinitic lamprophyres. The suites assemble one or more of following lithologies: (+/- quartz) gabbros and monzogabbros, (+/- quartz) diorites and monzodiorites, (+/- quartz) monzonites and syenites in addition to rare granites. All these rocks occur together in the Piracaia pluton, State of São Paulo. The mineralogy of the Piracaia suite comprises variable amounts of plagioclase (An 60-10), alkali-feldspars (orthoclase, microcline, albite), ortho- (Fe-hypersthene) and clinopyroxenes (augite), amphiboles (hornblende and rare late Fe-hastingsite), abundant biotite, quartz, opaques, sphene, allanite and zircon. Several magmatic pulses constructed the pluton. The Piracaia magma bulk trend evolved initially along the silica-undersaturation plane with simultaneous fractionation of accessory, mafic and felsic minerals. These are segregated in feldspar-rich cumulates. In the late stage, the evolutionary trend followed two distinct paths: one along the or-ab thermal barrier with the crystallization of syenites; the second one along the thermal valley in the or-ab-qz subsystem, producing quartz-syenites and granites. The source of the Piracaia magma was a 'vein-plus-wall-rock-system '. Together the pulses reflect increasing and decreasing participation of peridotites and mica pyroxenites, respectively, in the magmatogenic process. The magmatic pulses were stored in magma chambers, several drained by deep faults or fractures, which were successively reactivated and recharged. Each new pulse underwent mixing with earlier residual magma, followed by fractionation. During ascent through the hot and thickened post-collisional crust, the magma pulses underwent minor compositional changes by crustal contamination. The concentration of valuable elements (Cu, Zn, Gd) in the Piracaia pluton occurred during two phases of the magmatic evolution. Cu and Zn were enriched in cumulates and Gd was concentrated in residual quartz-syenitic veins. Due to their homogeneous dark colour and texture, the monzodiorites are exploited both for polished dimension stones and supports for sensitive scientific instruments. (C) 2001 Elsevier B.V. Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)