65 resultados para Pressure measurement


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Obesity is the most common nutritional problem in dogs and it can cause various harmful effects on animal health. However, the effect of this condition on systolic blood pressure (SBP) in obese dogs is controversial. The indirect method of measuring PAS is the most commonly used in veterinary medicine for the diagnosis of systemic hypertension, because it is more practical and easy to access. There is little scientific information about the comparison of the two non- invasive methods of measurement of blood pressure in obese dogs. Therefore, the objective of this study was to evaluate the SBP in obese dogs by comparing both indirect methods of measuring blood pressure, with oscillometric and doppler vascular in order to verify the differences in blood pressure values, but also the best method to assess the SBP dogs in this body score condition. The study complain blood pressure measurement of 50 dogs, with were divided in obese dogs with mean body condition score (BCS) of 8.42 +/- 0.50 (n = 25) and dogs with ideal BCS of 4.56 +/- 0.51 (n = 25). At comparison of blood pressure values, SBP values obtained by doppler method (152 +/- 16mmHg) were higher than the oscillometric (136 +/- 11mmHg). Correspondence analysis determined by multivariate statistical analysis showed correlation between body condition and the procedure of the SBP. These findings suggest that the indirect method doppler can better reflect the SBP in obese dogs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A espécie vegetal, Petroselinum sativum Hoff, conhecida como salsa, é amplamente utilizada na medicina popular brasileira como diurético. O objetivo desse estudo é verificar se o uso brasileiro do extrato aquoso da salsa tem efeitos semelhantes com investigações que mostram o efeito diurético da P. sativum em ratos. MÉTODOS: 19 Ratos foram anestesiados e canulamos a traquéia, artéria carótida esquerda (para a medição da pressão arterial) e bexiga urinária (para coletar urina). Depois de 40 minutos para adaptação das condições cirúrgicas, ratos anestesiados foram administrados de acordo com seus grupos: controle (CON), administração oral com 1.0 mL de água filtrada, e grupo tratado (AE), administração oral com extrato aquoso de sementes de salsa 20% (AE). Urina foi coletada três vezes (de 30 em 30 minutos) e então esse material foi utilizado para determinações de sódio e potássio, para avaliar a quantidade excretada desses íons. Pressão arterial foi medida pelo manômetro de mercúrio por 9 vezes. Todos os dados foram estatisticamente avaliados. RESULTADOS E CONCLUSÃO: nos parâmetros anestesiados, o grupo CON não mostrou nenhuma diferença; mas o grupo AE mostrou um aumento do fluxo urinário e da quantidade excretada de sódio e potássio, e também uma diminuição da pressão arterial. Todos os parâmetros apresentaram essas modificações após 30 minutos de administração do AE (p<0,05). Esses resultados mostram que o tratamento com o AE leva a efeitos natriurético e hipotensor em ratos Wistar anestesiados, confirmando o uso da população brasileira dessa erva como diurético.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Body composition has fundamental importance in the quality of life and is a powerful predictor of mortality and morbidity in humans. The identification and monitoring of the amount of body fat have been receiving special attention in aspects related to health promotion, not just for its actions in the prevention and in the control of cardiovascular diseases but also for their induction and association with risk factors, especially in the plasmatic lipid levels and arterial pressure. It was investigated the relationship between body mass index (BMI) and body fat percentage (%BF) by bioelectrical impedance analysis (BIA) with the blood pressure levels (systolic and diastolic) and serum lipids (TC, HDL-c, LDL-c, VLDL-c, TG). In a group of fifty seven women (aged 18 to 26 years old ), obesity was detected in 5 and 19 women by BMI (≥ 30 kg/m2) and %BF (≥ 30%), respectively. BMI and % BF were positively correlated with blood pressure (systolic and diastolic), and highly significant in the obese group by %BF. Moreover, BMI and % BF were significantly correlated with all lipids and lipoprotein fractions VLDL-c and triglyceride, respectively. These results suggest that %BF is a good indicator of “occult obesity” in subjects with normal body mass index. The associated use of BMI and %BF to better evaluate obesity may improve the study of blood pressure levels and serum lipid changes that are commonly associated with obesity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The influence of 2 different levels of the inspired oxygen fraction (FiO(2)) on blood gas variables was evaluated in dogs with high intracranial pressure (ICP) during propofol anesthesia (induction followed by a continuous rate infusion [CRI] of 0.6 mg/kg/min) and intermittent positive pressure ventilation (IPPV). Eight adult mongrel dogs were anesthetized on 2 occasions, 21 d apart, and received oxygen at an FiO(2) of 1.0 (G100) or 0.6 (G60) in a randomized crossover fashion. A fiberoptic catheter was implanted on the surface of the right cerebral cortex for assessment of the ICP. An increase in the ICP was induced by temporary ligation of the jugular vein 50 min after induction of anesthesia and immediately after baseline measurement of the ICP. Blood gas measurements were taken 20 min later and then at 15-min intervals for 1 h. Numerical data were submitted to Morrison's multivariate statistical methods. The ICP, the cerebral perfusion pressure and the mean arterial pressure did not differ significantly between FiO(2) levels or measurement times after jugular ligation. The only blood gas values that differed significantly (P < 0.05) were the arterial oxygen partial pressure, which was greater with G100 than with G60 throughout the procedure, and the venous haemoglobin saturation, that was greater with G100 than with G60 at M0. There were no significant differences between FiO(2) levels or measurement times in the following blood gas variables: arterial carbon dioxide partial pressure, arterial hemoglobin saturation, base deficit, bicarbonate concentration, pH, venous oxygen partial pressure, venous carbon dioxide partial pressure and the arterial-to-end-tidal carbon dioxide difference.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Surface treatment of polymers by discharge plasmas has increasingly found industrial applications due to its capability of modifying uniformly the surface without changing the material bulk properties. This work deals with surface modification of polyethylene terephthalate (PET) by a dielectric barrier discharge (DBD) at atmospheric pressure. The treatments were conducted in air, nitrogen or argon plasma. The polymer surface was characterized by contact angle measurement, X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The results show that the plasma treatment introduces oxygen-and nitrogen-related polar groups on the polymer surface and promotes the surface roughening. Both plasma-induced surface modifications contribute to the enhancement of the polymer wettability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A pressure analgesiometric device was developed for unrestrained cats. Eleven cats were studied. Stimulation was via three rounded pins within a bracelet on the forearm. The pins were advanced by manual bladder inflation. Bladder pressure was measured using a strain gauge pressure transducer. The threshold was recorded at the behavioural end point. Thresholds were measured at 5 and 15 min intervals for 2-4 h, after removal/replacement of the cuff, for 120 min after SC butorphanol (0.4 mg/kg), and with mild skin inflammation at the testing site. Data were analysed using ANOVA. Pressure thresholds in untreated cats were around 150 mmHg. The minimum interval for testing was established as 15 min. Data were reproducible over 4 h and beyond 24 h. Thresholds in 5 cats increased (P < 0.05) above baseline for 45 min after butorphanol with a maximum increase of 270 +/- 182 mmHg at 10 min. Thresholds decreased with inflammation. The method appears suitable for feline analgesia investigations. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Purpose: The circadian rhythm of melatonin in saliva or plasma, or of the melatonin metabolite 6-sulfatoxymelatonin (a6MTs) in urine, is a defining feature of suprachiasmatic nucleus (SCN) function, the body's endogenous oscillatory pacemaker. The primary objective of this review is to ascertain the clinical benefits and limitations of current methodologies employed for detection and quantification of melatonin in biological fluids and tissues. Data Identification: A search of the English-language literature (Medline) and a systematic review of published articles were carried out. Study Selection: Articles that specified both the methodology for quantifying melatonin and indicated the clinical purpose were chosen for inclusion in the review. Data Extraction: The authors critically evaluated the methodological issues associated with various tools and techniques (e.g. standards, protocols, and procedures). Results of Data Synthesis: Melatonin measurements are useful for evaluating problems related to the onset or offset of sleep and for assessing phase delays or advances of rhythms in entrained individuals. They have also become an important tool for psychiatric diagnosis, their use being recommended for phase typing in patients suffering from sleep and mood disorders. Additionally, there has been a continuous interest in the use of melatonin as a marker for neoplasms of the pineal region. Melatonin decreases such as found with aging are or post pinealectomy can cause alterations in the sleep/wake cycle. The development of sensitive and selective methods for the precise detection of melatonin in tissues and fluids has increasingly been shown to have direct relevance for clinical decision making. Conclusions: Due to melatonin's low concentration, as well as the coexistence of numerous other compounds in the blood, the routine determination of melatonin has been an analytical challenge. The available evidence indicates however that these challenges can be overcome and consequently that evaluation of melatonin's presence and activity can be an accessible and useful tool for clinical diagnosis. © Springer-Verlag 2010.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we developed a setup to measure the speed of sound in gases using a laser ultrasonics system. The mentioned setup is an all optical system composed by a Q-switched Nd:YAG laser to generate the sound waves, and a fiber optical microphone to detect them. The Nd:YAG provided a laser pulse of approximately 420 mJ energy and 9 ns of pulse width, at the wavelength of 1064 nm. The pulsed laser beam, focused by a positive lens, was used to generate an electrical breakdown (in the gas) which, in turn, generates an sound wave that traveled through a determined distance and reached the fiber optical microphone. The resulting signal was acquired in an oscilloscope and the time difference between the optical pulse and the arrival of the sound waves was used to calculate the speed of sound, since the distance was known. The system was initially tested to measure the speed of sound in air, at room pressure and temperature and it presented results in agreement with the theory, showing to be suitable to measure the speed of sound in gases. © 2012 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Early trauma care is dependent on subjective assessments and sporadic vital sign assessments. We hypothesized that near-infrared spectroscopy-measured cerebral oxygenation (regional oxygen saturation [rSO 2]) would provide a tool to detect cardiovascular compromise during active hemorrhage. We compared rSO 2 with invasively measured mixed venous oxygen saturation (SvO2), mean arterial pressure (MAP), cardiac output, heart rate, and calculated pulse pressure. Methods: Six propofol-anesthetized instrumented swine were subjected to a fixed-rate hemorrhage until cardiovascular collapse. rSO 2 was monitored with noninvasively measured cerebral oximetry; SvO2 was measured with a fiber optic pulmonary arterial catheter. As an assessment of the time responsiveness of each variable, we recorded minutes from start of the hemorrhage for each variable achieving a 5%, 10%, 15%, and 20% change compared with baseline. Results: Mean time to cardiovascular collapse was 35 minutes ± 11 minutes (54 ± 17% total blood volume). Cerebral rSO 2 began a steady decline at an average MAP of 78 mm Hg ± 17 mm Hg, well above the expected autoregulatory threshold of cerebral blood flow. The 5%, 10%, and 15% decreases in rSO 2 during hemorrhage occurred at a similar times to SvO2, but rSO 2 lagged 6 minutes behind the equivalent percentage decreases in MAP. There was a higher correlation between rSO 2 versus MAP (R =0.72) than SvO2 versus MAP (R =0.55). Conclusions: Near-infrared spectroscopy- measured rSO 2 provided reproducible decreases during hemorrhage that were similar in time course to invasively measured cardiac output and SvO2 but delayed 5 to 9 minutes compared with MAP and pulse pressure. rSO 2 may provide an earlier warning of worsening hemorrhagic shock for prompt interventions in patients with trauma when continuous arterial BP measurements are unavailable. © 2012 Lippincott Williams & Wilkins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate the sound pressure level to which preschool students are exposed. Method: This was a prospective, quantitative, nonexperimental, and descriptive study. To achieve the aim of the study we used an audio dosimeter. The sound pressure level (SPL) measurements were obtained for 2 age based classrooms. Preschool I and II. The measurements were obtained over 4 days in 8-hour sessions, totaling 1920 minutes. Results: Compared with established standards, the SPL measured ranged from 40.6 dB (A) to 105.8 dB (A). The frequency spectrum of the SPL was concentrated in the frequency range between 500 Hz and 4000 Hz. The older children produced higher SPLs than the younger ones, and the levels varied according to the activity performed. Painting and writing were the quietest activities, while free activities period and games were the noisiest. Conclusion: The SPLs measured at the preschool were higher and exceeded the maximum permitted level according to the reference standards. Therefore, the implementation of actions that aim to minimize the negative impact of noise in this environment is essential.