159 resultados para Penetration Depth
Resumo:
The stretch zone width (SZW) data for 15-5PH steel CTOD specimens fractured at -150 degrees C to + 23 degrees C temperature were measured based on focused images and 3D maps obtained by extended depth-of-field reconstruction from light microscopy (LM) image stacks. This LM-based method, with a larger lateral resolution, seems to be as effective for quantitative analysis of SZW as scanning electron microscopy (SEM) or confocal scanning laser microscopy (CSLM), permitting to clearly identify stretch zone boundaries. Despite the worst sharpness of focused images, a robust linear correlation was established to fracture toughness (KC) and SZW data for the 15-5PH steel tested specimens, measured at their center region. The method is an alternative to evaluate the boundaries of stretched zones, at a lower cost of implementation and training, since topographic data from elevation maps can be associated with reconstructed image, which summarizes the original contrast and brightness information. Finally, the extended depth-of-field method is presented here as a valuable tool for failure analysis, as a cheaper alternative to investigate rough surfaces or fracture, compared to scanning electron or confocal light microscopes. Microsc. Res. Tech. 75:11551158, 2012. (C) 2012 Wiley Periodicals, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The spatial variability of mechanical resistance to penetration (PR) and gravimetric moisture (GM) was studied at a depth of 0-0.40 m, in a ferralsol cropped with corn, and under conventional tillage in llha Solteira, Brazil (latitude 20 degrees 17'S, and longitude 52 degrees 25'W). The purpose of this study was to analyse and to try explaining the spatial variability of the mentioned soil physical properties using geostatistics. Soil data was collected at points arranged on the nodes of a mesh with 97 points. Geostatistics was used to analyse the spatial variability of PR and GM at four depths: 0-0. 1, 0.1-0.2, 0.2-0.3 and 0.3-0.4 m. PR showed a higher variability of data, with coefficients of variation of 52.39, 30.54, 16.91, and 15.18%, from the surface layers to the deepest layers. The values of the coefficients of variation for GM were lower: 9.99, 5.13, 5.59, and 5.69%. Correlation between GM and PR for the same soil layers was low. Penetration resistance showed spatial structure only in the 0.30-0.40 m layer, while gravimetric moisture showed spatial structure at all depths except for 0-0. 10 m. All the models of fitted semivariograms were spherical and exponential, with ranges of 10-80 m. Data for the variable 'GM' in the 0.20-0.30 and 0.30-0.40 m layers revealed a trend in data attributed to the occurrence of subsurface water flow. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The recovery of native area used in hydroelectric power station construction is a slow process, and it requires the use of covering plant as a source of organic matter, application of nutrients and amendments as soil conditioner. Thus, this study has the objective to study the recovery of physical attribute of subsoil in a distrophic Red Latosol, used in the embankment and foundation of Hydroelectric Power Station, Ilha Solteira, São Paulo, Brazil. The design used was randomized blocks with eight treatments and four replications. The research started in 1992. The treatments consisted of green manure, pasture and soil amendment. After 13 years, total porosity, macroporosity, microporosity, bulk density, aggregate stability, resistance to penetration, organic matter of soil and dry matter of pasture production were evaluated. The adopted treatments are slowly contributing towards recovery of physical attributes of exposed subsoil. The effects of the soil recovery are reaching 0-0.10 m depth.
Resumo:
Objective-To evaluate the correlation between the bispectral index (BIS) and end-tidal isoflurane (ETISO) concentration and compare the use of 3 BIS sensor positions in dogs.Animals-6 adult dogs.Procedures-Mechanically ventilated dogs received pancuronium, and depth of anesthesia was altered by increasing ETISO concentration from 1.5% to 2.3% and 3.0%. The BIS, suppression ratio (relative percentage of isoelectric electroencephalographic waveforms), and signal quality index (SQI) were recorded at each ET, so concentration for each of 3 BIS sensor positions (frontal-occipital, bifrontal, and frontal-temporal positions).Results-The BIS and ETISO concentration were poorly correlated-, regardless of sensor positioning, mean BIS values did not change significantly as ETISO was increased. At 3% isoflurane, regardless of sensor positioning, there was an increase in suppression ratio coincident with BIS < 40 in some dogs, whereas paradoxic increases in BIS (> 60) were recorded in others. Furthermore, at 3.0% isoflurane, the SQI was significantly lower for the bifrontal sensor position (compared with values for the other positions), but low SQI values prevented recording of BIS values from the frontal-occipital sensor position in 2 dogs. Overall, BIS values derived from the 3 sensor positions did not differ.Conclusions and Clinical Relevance-In dogs, BIS values may not reflect changes in depth of isoflurane anesthesia in the absence of noxious stimulation. of the 3 sensor positions, frontal-temporal positioning provided better correlation with changes in depth of anesthesia induced via changes in isoflurane concentrations. However, the sensor placements yielded similar results at SQI values > 50.
Resumo:
Experiments evaluated the ability of follicular fluid (FF), dilauroylphosphatidylcholine (PC12) and the calcium ionophore A23187 (A23187) to induce capacitation in stallion and bull spermatozoa, determined by the ability of the spermatozoa to penetrate zona-free hamster, bovine and equine oocytes. Spermatozoa suspensions were incubated at 37 degreesC in one of the following treatments: 1) a modified Tyrode's medium (BGM3) alone, 2) BGM3 + FF; 3) BGM3 + PC12; 4) BGM3 + FF + PC12; 5) BGM3 + A23187; and 6) BGM3 + FF + A23187. Treated spermatozoa were incubated with zona-free hamster, bovine and equine oocytes for 3 h, after which oocytes were stained to assess spermatozoa penetration. The number of hamster oocytes penetrated by spermatozoa incubated in BGM3 alone (1/30) or in presence of FF (2/31) was significantly lower (P < 0.05) than by spermatozoa treated with PC12 or A23187 (16/30 and 17/30, respectively). Processing stallion spermatozoa either by a swim-up procedure or by centrifugation through a Percoll gradient increased the percentages of motile spermatozoa in the final sample, and spermatozoa collected by both processes penetrated similar numbers of zona-free hamster oocytes (P > 0.05). Although treating spermatozoa with PC12 or A23187 enabled both stallion and bull spermatozoa to penetrate oocytes, higher numbers of bovine oocytes were penetrated by bull spermatozoa (25/30) than by stallion spermatozoa (4/30) regardless of spermatozoal treatment. However, the number of zona-free hamster and equine oocytes penetrated by bull spermatozoa (25/30 and 12/18 respectively) and stallion spermatozoa (17/30 and 15/21 respectively) were similar (P > 0.05). We conclude that both PC12 and A23187 capacitate stallion and bull spermatozoa sufficiently to permit the acrosome reaction to occur, enabling spermatozoa to penetrate homologous and heterologous zona-free oocytes. (C) 2001 by Elsevier B.V.
Resumo:
The purpose of this study was to evaluate the polymerization effectiveness of a composite resin (Z-250) utilizing microhardness testing. In total, 80 samples with thicknesses of 2 and 4 mm were made, which were photoactivated by a conventional halogen light-curing unit, and light-curing units based on LED. The samples were stored in water distilled for 24 h at 37C. The Vickers microhardness was performed by the MMT-3 microhardness tester. The microhardness means obtained were as follows: G1, 72.88; G2, 69.35; G3, 67.66; G4, 69.71; G5, 70.95; G6, 75.19; G7, 72.96; and G8, 71.62. The data were submitted to an analysis of variance (ANOVA's test), adopting a significance level of 5%. The results showed that, in general, there were no statistical differences between the halogen and LED light-curing units used with the same parameters.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The present study was designed to analyse the average depth of the microporosity of a nickel-chromium (Ni-Cr) system alloy (Verabond II). The metal surface was subject to one of the following surface treatment: (i) Electrolytic etching in nitric acid 0.5 N at a current density of 250 mA cm(-2) ; (ii) chemical etching with CG-Etch etchant; and (iii) Sandblasting with alumina particles 50 mum. Half of the samples were polished before the surface treatments. The depth of porosity was measured through photomicrographs (500x) with a profilometer, and the data were statistically analysed using an analysis of variance (anova) followed by Tukey's test. The conclusions were (i) Differents surface treatment of the Ni-Cr system alloy lead to different depths of microporosity; (ii) the greatest depth of porosity was observed in non-polished alloy; (iii) the greatest and identical depth of microporosity was observed following electrolytic etching and chemical etching; (iv) the least and identical depth of microporosity was observed with chemical etching and sandblasting with alumina particles 50 mum, and (v) Chemical etching showed an intermediary depth.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)