88 resultados para Occlusal equilibrium


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A self-consistent equilibrium calculation, valid for arbitrary aspect ratio tokamaks, is obtained through a direct variational technique that reduces the equilibrium solution, in general obtained from the 2D Grad-Shafranov equation, to a 1D problem in the radial flux coordinate rho. The plasma current profile is supposed to have contributions of the diamagnetic, Pfirsch-Schluter and the neoclassical ohmic and bootstrap currents. An iterative procedure is introduced into our code until the flux surface averaged toroidal current density (J(T)), converges to within a specified tolerance for a given pressure profile and prescribed boundary conditions. The convergence criterion is applied between the (J(T)) profile used to calculate the equilibrium through the variational procedure and the one that results from the equilibrium and given by the sum of all current components. The ohmic contribution is calculated from the neoclassical conductivity and from the self-consistently determined loop voltage in order to give the prescribed value of the total plasma current. The bootstrap current is estimated through the full matrix Hirshman-Sigmar model with the viscosity coefficients as proposed by Shaing, which are valid in all plasma collisionality regimes and arbitrary aspect ratios. The results of the self-consistent calculation are presented for the low aspect ratio tokamak Experimento Tokamak Esferico. A comparison among different models for the bootstrap current estimate is also performed and their possible Limitations to the self-consistent calculation is analysed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to a loss of chewing efficiency and a loss of vertical dimension of occlusion. The use of metal occlusal surfaces on the acrylic resin denture teeth will minimize occlusal wear. Several articles have described methods to construct metal occlusal surfaces; however, these methods are time-consuming, costly, and sometimes considered to be unesthetic. These methods also require that the patient be without the prosthesis for the time necessary to perform the laboratory procedures. This article presents a quick, simple, and relatively inexpensive procedure for construction of composite occlusal surfaces on complete and partial dentures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The molar single ion activity coefficients associated with hydrogen, copper(II), cadmium(II) and lead(II) ions were determined at 25 degrees C and ionic strengths between 0.100 and 3.00 M (NaClO4), whereas for acetate the ionic strengths were fixed between 0.300 and 2.00 M, held with the same inert electrolyte. The investigation was carried out potentiometrically by using proton-sensitive glass, copper, cadmium and lead ion-selective electrodes and a second-class Hg\Hg-2(CH3COO)(2) electrode. It was found that the activity coefficients of these ions (y(i)) can be assessed through the following empirical equations:log y(H) = -0.542I(0.5) + 0.451I; log y(Cu) = -1.249I(0.5) + 0.912I; log y(Cd) = -0.829I(0.5) + 0.448I(1.5);log y(Pb) = -0.404I(0.5) + 0.117I(2); and log y(Ac) = 0.0370I .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to 'detect occlusal caries.Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site.Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy far the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly.Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the Sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure.Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the performance of visual (International Caries Detection and Assessment System [ICDAS]) and radiographic (bitewing [BW]) examinations for occlusal caries detection and their associations with treatment decision (TD). Permanent teeth (n=104) with occlusal surfaces varying from sound to cavitated were selected. Sites were identified from 10x occlusal surface photographs. Standardized bitewing (BW) radiographs were taken. Four dentists with at least five years of experience scored all teeth twice (one-week interval) for ICDAS (0-6), BW (0=sound, 1=caries restricted to enamel, 2=caries in outer third dentin, 3=caries in inner third dentin), and TD (0=no treatment, 1=sealant, 2=microabrasion and sealant, 3=round bur sealant, 4a=resin, 4b=amalgam). Histological validation was performed by observation under a light microscope, with lesions classified on a five-point scale. Intraexaminer and inter-examiner repeatability were assessed using two-way tables and intraclass correlation coefficients (ICCs). Comparisons between percentage correct, specificity, sensitivity, and area under the receiver-operating characteristic (ROC) curve were performed using bootstrap analyses. ICCs for intraexaminer and interexaminer repeatability indicated good repeatability for each examiner, ranging from 0.78 to 0.88, and among examiners, ranging from 0.74 to 0.81. Correlation between ICDAS and TD was 0.85 and between BW and TD was 0.78. Correlation between the methods and histological scores was moderate (0.63 for ICDAS and 0.61 for BW). The area under the ROC curve was significantly greater for ICDAS than for BW (p<0.0001). ICDAS had significantly lower specificity than BW did (p=0.0269, 79% vs 94%); however, sensitivity was much higher for ICDAS than for BW (p<0.0001, 83% vs 44%). Data from this investigation suggested that the visual examination (ICDAS) showed better performance than radiographic examination for occlusal caries detection. The ICDAS was strongly associated with TD. Although the correlation between the ICDAS and BW was lower, it is still valuable in the clinical decision-making process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The equilibrium and kinetics of methemoglobin conversion to hemichrome induced by dehydration were investigated by visible absorption spectroscopy. Below about 0.20 g water per g hemoglobin only hemichrome was present in the sample; above this value, an increasing proportion of methemoglobin appeared with the increase in hydration. The transition between the two derivatives showed a time-dependent biphasic behavior and was observed to be reversible. The rates obtained for the transition of methemoglobin to hemichrome were 0.31 and 1.93 min-1 and for hemichrome to methemoglobin 0.05 and 0.47 min-1. We suggest that hemichrome is a reversible conformational state of hemoglobin and that the two rates observed for the transition between the two derivatives reflect the α- and β-chains of hemoglobin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the penetration of a light-cured glass ionomer and a resin sealant into occlusal fissures and etched enamel. MATERIALS AND METHODS: Forty-eight maxillary and mandibular caries-free premolars scheduled for extraction for orthodontic reasons were isolated, the occlusal surfaces subjected to prophylaxis and acid-etched with orthophosphoric acid prior to the application of the VariGlass VLC glass ionomer and Concise resin sealants. The teeth were extracted, two longitudinal median sectiors from each tooth were ground to a thickness of 80-100 microns, and the sealant penetration into the fissures evaluated. The sections were placed in nitric acid to dissolve the enamel so the lengths of the tags which had penetrated into the etched enamel could be measured at different sites on the walls of the fissures. RESULTS: Both sealants adapted well to the fissures but penetrated deeper into shallow, open fissures than into deep, constricted fissures. The VariGlass VLC tags into etched enamel were generally longer than the Concise projections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mathematical programming problems with equilibrium constraints (MPEC) are nonlinear programming problems where the constraints have a form that is analogous to first-order optimality conditions of constrained optimization. We prove that, under reasonable sufficient conditions, stationary points of the sum of squares of the constraints are feasible points of the MPEC. In usual formulations of MPEC all the feasible points are nonregular in the sense that they do not satisfy the Mangasarian-Fromovitz constraint qualification of nonlinear programming. Therefore, all the feasible points satisfy the classical Fritz-John necessary optimality conditions. In principle, this can cause serious difficulties for nonlinear programming algorithms applied to MPEC. However, we show that most feasible points do not satisfy a recently introduced stronger optimality condition for nonlinear programming. This is the reason why, in general, nonlinear programming algorithms are successful when applied to MPEC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the effect of different microwave curing cycles on the changes in occlusal vertical dimension of complete dentures. Four test groups with 12 maxillary dentures each were evaluated. Groups 1, 2 and 3 were polymerized with different cycles by microwave radiation and Group 4 was the control and cured by water bath. The average pin opening for all groups was less than 0.5 mm. There was no significant difference between the groups polymerized by the microwave method and the control group. However, analyses of the vertical dimension changes showed statistically significant differences between groups 2 (0.276 +/- 0.141 mm) and 3 (0.496 +/- 0.220 mm).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loss of function, muscle inflammation, and pain are some of the signs and symptoms of temporomandibular dysfunction (TMD). Pharmacological strategies to minimize the clinical manifestation of these disorders often focus on blocking or inhibiting the pain-causing symptom. Resources such as muscle-relaxants, anxiety-relief drugs, and splint therapy are often used to reduce muscular hyperactivity related to TMD muscle pain. This study compares the effect of a randomly ordered association of occlusal splint therapy (S), nonsteroid anti-inflammatory with a muscle-relaxant drug (orphenadrine citrate) (O), and an anxiety-relief drug (benzodiazepine) (B), to ease painful TMD muscle symptoms. Clinical and anamnestic analyses were recorded in accordance with the Helkimo TMD index and applied before and after treatments. Twenty-one group two Helkimo TMD adult female patients were treated, all of whom were subjected to the three random therapeutic associations proposed: SBO, BOS, and OSB. The same operator applied the three specific associations over a period of 21 days in the proposed sequence, seven days for each therapy. The results show that all the groups presented the best results in terms of relief from pain after the therapeutic association (28.5% showed a decrease and 47.6% showed an absence of symptoms). No significant difference was observed among association therapeutic protocols. Copyright © 2003 by CHROMA, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Restorative dentistry has been increasingly concerned with preservation of the dental structure. For that reason, ultraconservative cavity preparations have been performed with air abrasion systems. The aim of this study was to present treatment options for the occlusal surface of first permanent molars with employment of the conventional method and the air abrasion system for accomplishment of the cavity preparation and a composite occlusal matrix for an accurate reproduction of the tooth surface.