164 resultados para Magnetron discharges


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Retention of particulate organic matter was investigated over a range of water discharges in pool and riffle zones of a tropical stream (Itauna Stream, São Paulo, Brazil). A closed-system leaf release and capture method was used to quantify leaf retention in a 50-m reach of the stream. Instantaneous retention rates (k) were calculated by a negative exponentialmodel and specific retention rates (ke) computed for each 1m interval. The mean k was 0.0161 +/- 0.0101 (S.E.) and ranged from 0.005 to 0.036 during the study period. This suggests a low retention of particulate matter. The evidence provided by this study shows that there was a relationship between retention and discharge. At low discharges, greater percentages of leaves were retained in a 3-h period while high discharges resulted in low retention percentages within the studied reach. In the Itauna Stream, no significant difference (p < 0.05) was found between the ke values of pool and riffle zones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neste trabalho são apresentadas duas técnicas para a avaliação da dispersão, num corpo d'água receptor, do efluente líquido de uma refinaria de petróleo. Assim, a pluma de dispersão foi caracterizada por medidas em campo de condutividade elétrica e por simulação computacional (simulador Cormix). Como caso de estudo, escolheu-se uma refinaria de petróleo cujo efluente é lançado no rio Atibaia (Paulínia/SP). O comportamento do efluente foi avaliado em um trecho de 1000 m após o ponto de lançamento. Os resultados demonstraram que a medição da condutividade elétrica é uma técnica adequada para a avaliação da dispersão de efluentes líquidos de refinaria de petróleo, pois apresentam alta condutividade elétrica e, com isso, há um forte contraste entre os valores do efluente e do rio. Além disso, outros parâmetros de qualidade da água do rio seguiram comportamento de dispersão semelhante ao da condutividade. A pluma de dispersão gerada pelo simulador computacional apresentou uma elevada concordância com os dados obtidos em campo. Nesse sentido, a simulação computacional pode ser uma ferramenta útil para a avaliação da dispersão do efluente considerando-se cenários hipotéticos, e para projetos de emissários.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relative condition factor (Kn), gonadosomatic index (GSI), selected hematological variables and gill morphology of the fish Astyanax fasciatus were analyzed in two sites (site I was unpolluted and site 2 was polluted with untreated domestic sewage) of a tropical river (Camanducaia river, São Paulo State, Brazil). The relationship between the body mass (M-B) and the standard length (L-S) of A. fasciatus from both sites was M-B = 0.00799 L-S(3.51843). Tyhe Kn values from both the males and females were significantly higher in site 2. The mean corpuscular hemoglobin and mean corpuscular hemoglobin concentration were higher in females from site 2. Gill tissue anomalies and gill parasites were rare in fish from both sites; however, the number of chloride cells was significantly higher in fish from site 1. A. fasciatus presents high capacity to live in ion-poor and soft water and is able to compensate for environmental changes caused by untreated domestic sewage discharges. (c) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes an optical device for the simultaneous recording of shadowgrams and schlieren images, and some results are presented concerning its applications to the study of plasma assisted flow control in airfoil models. This approach offers many advantages in comparison to other methods, specially because the use of tracer particles (like smoke in wind tunnels) is not required for the experiments, thus avoiding contaminations in the electric discharges or air flows. Besides, while schlieren images reveal the refractive index gradients in the area of study, shadowgrams detect the second order spatial derivatives of the refractive indexes. Therefore, the simultaneous recording of these different images may give interesting information about the phenomena under study. In this paper, these images were used to confirm the existence of vortex structures in the flow induced by corona discharges on airfoil models. These structures are a possible explanation for the effects of drag reduction and lift force increasing, which have been reported in experiments of plasma assisted Aerodynamics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes an optical device for the simultaneous recording of shadowgrams and schlieren images, and some results are presented concerning its application to the study of plasma assisted flow control in airfoil models. This approach offers many advantages in comparison to other methods, specially because the use of tracer particles (like smoke in wind tunnels) is not required for the experiments, thus avoiding contaminations in the electric discharges or air flows. Besides, while schlieren images reveal the refractive index gradients in the area of study, shadowgrams detect the second order spatial derivatives of the refractive indexes. Therefore, the simultaneous recording of these different images may give interesting information about the phenomena under study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. To test the hypothesis that multiple firing and silica deposition on the zirconia surface influence the bond strength to porcelain.Materials and methods. Specimens were cut from yttria-stabilized zirconia blocks and sintered. Half of the specimens (group S) were silica coated (physical vapor deposition (PVD)) via reactive magnetron sputtering before porcelain veneering. The remaining specimens (group N) had no treatment before veneering. The contact angle before and after silica deposition was measured. Porcelain was applied on all specimens and submitted to two (N2 and S2) or three firing cycles (N3 and S3). The resulting porcelain-zirconia blocks were sectioned to obtain bar-shaped specimens with 1 mm(2) of cross-sectional area. Specimens were attached to a universal testing machine and tested in tension until fracture. Fractured surfaces were examined using optical microscopy. Data were statistically analyzed using two-way ANOVA, Tukey's test (alpha = 0.05) and Weibull analysis.Results. Specimens submitted to three firing cycles (N3 and S3) showed higher mean bond strength values than specimens fired twice (N2 and S2). Mean contact angle was lower for specimens with silica layer, but it had no effect on bond strength. Most fractures initiated at porcelain-zirconia interface and propagated through the porcelain.Significance. The molecular deposition of silica on the zirconia surface had no influence on bond strength to porcelain, while the number of porcelain firing cycles significantly affected the bond strength of the ceramic system, partially accepting the study hypothesis. Yet, the Weibull modulus values of S groups were significantly greater than the m values of N groups. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A face lateral do corpo da mandíbula de ratos foi irradiada pelo laser CO2 com disparos contínuos de 10watts de potência. Após três meses, o sulco formado pela irradiação apresentou, em uma grande extensão, material fundido com diversas fraturas. Após sete meses, o periósteo neoformado recobriu amplas áreas da incisão, que apresentou ainda material carbonizado. Um ano após a incisão, o periósteo neoformado estava composto por fibras colágenas, que formaram feixes espessos, transversais à incisão, ou malhas regulares, que recobriram a incisão. Ainda nessa fase, resquícios de material carbonizado foram verificados, caracterizando um retardo na regeneração óssea

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work it was investigated the effect of the exposure to different plasmas on the wettability of silicone samples. We have observed that oxygen. argon, and hydrogen glow discharges are quite effective in reducing the water contact angle of such polymer. However, indifferently to efficiency of the treatment, practically all the modified surfaces recovered great part of their original hydrophobicity. We have investigated this hydrophobic recovery using surface energy measurements and theoretical simulations based on the exponential decay of the population of polar groups on the surface. According to our results such recovery can be attributed to the decrease of polar species at the interface water-polymer surface.