54 resultados para MINI-FLYING ROBOTS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The retromolar triangle is a triangular area located in the mandible, posteriorly to the last molar. This region, due its thickness and bone density, is widely used for the installation of devices that provide an anchorage system for the movement of the lower molars. The aim of this research is to provide morphometric data of the mucosa thickness of the retromolar triangle. Twenty-five patients of portuguese nationality, with indication for extraction of the impacted lower third molar (right and/or left), were studied. In the region of the retromolar triangle were demarcated 3 points corresponding to the vertices of a triangle whose the base was torned for the distal face of the lower third molar and the lenght of the sides corresponded to vestibulolingual dimension of the same tooth, then was demarcated a fourth point corresponding to the geometric center of the triangle. Then, using a finger spreader with silicone stop were measured the mucosal tickness at each point. The data obtained were tabulated and analyzed. The lowest average value found was 5.5mm on the right side and the highest average value found was 7.13mm on the left side. Considering the mean values obtained at the points of the retromolar triangle mucosa measured in this study, we conclude that the retromolar triangle shows thick mucosa, so the mini-implants indicated for this region should have a long transmucosal neck.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Horticultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orthodontic mini-implants are used in clinical practice to provide efficient and aesthetically-pleasing anchorage. AIM: To evaluate the hardness Vickers hardness and chemical composition of mini-implant titanium alloys from five commercial brands. METHODS: Thirty self-drilling mini-implants, six each from the following commercial brands, were used: Neodent NEO, Morelli MOR, Sin SIN, Conexão CON, and Rocky Mountain RMO. The hardness and chemical composition of the titanium alloys were performed by the Vickers hardness test and energy dispersive X-ray spectroscopy, respectively. RESULTS: Vickers hardness was significantly higher in SIN implants than in NEO, MOR, and CON implants. Similarly, VH was significantly higher in RMO implants than in MOR and NEO ones. In addition, VH was higher in CON implants than in NEO ones. There were no significant differences in the proportions of titanium and aluminum in the mini-implant alloy of the five commercial brands. Conversely, the proportion of vanadium differed significantly between CON and MOR/NEO implants. CONCLUSIONS: Mini-implants of different brands presented distinct properties of hardness and composition of the alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Production of mini vegetables in organic system is a good alternative to improve profit, but there are no researches about the optimum plant density for these cultivars in Brazilian conditions. Two experiments were conducted to evaluate the production of mini lettuce cultivars in different plant densities. Experiment 1 was conducted from January 1th (sowing) to February 10th (harvesting), 2012. The experimental design was completely randomized blocks, with six treatments in factorial scheme, 3 mini lettuce cultivars (Tudela, Renoir and Sartre) x 2 spacing between plants (16 and 20 cm), with eight replications and plots (2.04 m(2)) with six rows, spaced 15 cm. Experiment 2 was conducted from June 6th (sowing) to July 18th (harvesting), 2012. The cultivars Sartre and Renoir were evaluated under four plant densities (444,444; 333,333; 266,667 and 200,000 plants ha(-1), corresponding to spacing of 15x15, 15x20, 25x15 and 25x20 cm, respectively). Eight treatments were defined by a factorial scheme 2 (cultivars) x 4 (plant densities) and arranged in a completely randomized block design, with nine replications and plots with 2.04 m2. The evaluated characteristics in both experiments were total and marketable fresh weight per plant, plant dry weight, plant diameter and height, marketable yield and discard percentage. In first experiment, during the summer, cultivar Sartre showed the highest marketable fresh weight (72 g plant(-1)). Heaviest plants (91.6 g plant(-1)) were obtained with the higher plant spacing, but the highest yield (2.51 kg m(-2)) was obtained with the smaller spacing. In winter, plants with higher total (190 g plant(-1)) and marketable (146 g planta(-1)) fresh weight were obtained with cultivar Sartre, and the same was observed in low plant density. However, the higher plant density, the higher the yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and oblique (45 degrees) loads were applied in the occlusal surface of the crowns by using a universal testing machine (EMIC). The stresses were photographically recorded and qualitatively analyzed using a software (Adobe Photoshop). Under axial loading, the number of fringes was inversely proportional to the diameter of the implants in the single crown models. In the splinted 3-unit piece, the 3.75-mm implant promoted lower number of fringes regardless of loading area application. Under oblique loading, a slight increase of fringes number was observed for all groups. The standard implant diameter promoted better stress distribution than the narrow and mini diameter implants. Additionally, the splinted crowns showed a more uniform stress distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last decade mini-screws have gained popularity in orthodontics field and a correct placement of mini-screws is a critical point to the success of the skeletal anchorage. A careful clinical and radiographic diagnostic before insertion mini-screw is an essential requirement to achieve the central point of the radicular septum. The correct application of these pre-surgical procedures should avoid possible iatrogenic damages in periodontal ligament, dental roots, nasomaxillary cavities, or even important vascular tissues. As of today, periapical radiographs is a regular pre surgical procedure during mini-screw insertion technique. Nevertheless, accurate execution of the radiographic parallax technique can offer to us useful and precise radiographic images, to decide the right local insertion of mini-screws in to the septum bone. The purpose of this paper is to describe the ¬application of new positioning circular guides in conjunction with a ¬parallax radiographic protocol before placement of orthodontic mini-screws.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The introduction of more efficient diagnostic methods, new techniques in surgery and transplantation, antibiotics and chemotherapeutics more potent and novel materials for prostheses, catheters and probes significantly increased the life expectancy and quality of life of critically ill patients, on the other hand, hospital-acquired infections emerged as important iatrogenic complications. Invasive infections are a growing problem in public health hospitals in Brazil and worldwide. Among the various etiological agents found in the hospital environment, the genus Candida has been the third most frequently isolated pathogen. In general, invasive fungal infections are associated with high morbidity and mortality, difficulties in diagnosis, antimicrobial resistance, length of hospital stay and increased hospital costs. This mini review of the literature describes about epidemiology of hospital infection of Candida species, as well as its virulence factors and drugs resistance

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of images as a mean of human knowledge transmission dates from the earliest records of visual communication with the cave paintings. Throughout history, the communicating function remained and was extended for a variety of approaches, including illustration, which plays an important role by transmitting a content to be communicated on a creative and unique way. The advertising area relies largely on the communicative power of illustration, using it as a visual aid on different ways and medias. The advertising pieces aimed at the automotive sector – especially those developed by BMW for the Mini Cooper model – broadly employs illustrations to spread the word about the product and its attributes, seeking to communicate it using an original way. With a qualitative approach to the case study, this article analyzes the illustrations produced by the South African design studio Am I Collective as part of a video prepared by South African advertising agency Blackriver FC as a celebration campaign for the fifty years of vehicle Mini Cooper, celebrated on 2009, and it aims to identify the illustrations visuals and compositions used in the construction of the covered temporal panorama.