109 resultados para Laser synchrotron radiation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hydrogenated bulk Zn1-xCoxO samples were synthesized via standard solid-state reaction route with Co molar concentrations up to 15 at.%. Magnetic characterization demonstrates a room temperature ferromagnetic behavior associated to a paramagnetic Curie-Weiss component. Detailed microstructural analysis was carried out to exclude the presence of extrinsic sources of ferromagnetism. The magnetization increases linearly as a function of Co concentration. Hall measurements reveal an insulating character for the whole set of samples. In this context, the defect mediated magnetic coupling between the Co atoms under the scope of the bound magnetic polarons model is used to interpret the observed room temperature ferromagnetism. © 2012 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The X-ray Fluorescence (XRF) analysis is a technique for the qualitative and quantitative determination of chemical constituents in a sample. This method is based on detection of the characteristic radiation intensities emitted by the elements of the sample, when properly excited. A variant of this technique is the Total Reflection X-ray Fluorescence (TXRF) that utilizes electromagnetic radiation as excitation source. In total reflection of X-ray, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample support interface. Thus, there is a minimum angle of incidence at which no refracted beam exists and all incident radiation undergoes total reflection. In this study, we evaluated the influence of the energy variation of the beam of incident x-rays, using the MCNPX code (Monte Carlo NParticle) based on Monte Carlo method. © 2013 AIP Publishing LLC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents the results obtained from selenium fractionation in plasma, muscle and liver samples of Nile tilapia's (Oreochromis niloticus) after protein separation. The plasma, muscle and liver proteome was obtained by 2D-PAGE, and selenium in protein spots was qualitatively and quantitatively determined by synchrotron radiation X-ray fluorescence and graphite furnace atomic absorption spectrometry (GFAAS). The fluorescence spectra indicated the presence of selenium in three protein spots of plasma, two of muscle and one of liver. Selenium was found to be distributed mainly in proteins with a molar mass smaller than 57.0 kDa and with pI in the range of 5.9-9.6, with one exception in the plasma sample, which presented protein with a molar mass of 60.0 kDa. After acid mineralization of the protein spots, a GFAAS determination of the concentration of selenium bound to these proteins indicated a range of 1.35-6.82 mg per g of protein. © 2013 Springer Science+Business Media New York.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Breast cancer is a public health problem throughout the world. Moreover, breast cancer cells have a great affinity for hydroxyapatite, leading to a high occurrence of bone metastasis. In this work we developed a bio-nanocomposite (bio-NCP) in order to use such affinity in the diagnosis and treatment of breast cancer. The bio-NCP consists of magnetic nanoparticles of Mn and Zn ferrite inside a polymeric coating (chitosan) modified with nanocrystals of apatite. The materials were characterized with synchrotron X-ray Powder Diffraction (XPD), Time-of-Flight Neutron Powder Diffraction (NPD), Fourier Transformed Infra-red Spectroscopy (FTIR), Scanning Electron Microscopy (SEM) and magnetic measurement with a Physical Property Measurement System (PPMS). We obtained ferrite nanoparticles with a high inversion degree of the spinel structure regarding the Fe and Mn, but with all the Zn in the A site. The coating of such nanoparticles with chitosan had no notable effects to the ferrite microstructure. In addition, the polymeric surface can be easily modified with apatite nanocrystals since the hydration of the bio-NCP during synthesis can be controlled. The resulting bio-NCP presents a spherical shape with a narrow size distribution and high magnetic response at room temperature and is a very promising material for early diagnosis of breast cancer and its treatment. © 2013 Elsevier B.V.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The X-ray fluorescence analysis (XRF) is an important technique for the qualitative and quantitative determination of chemical components in a sample. It is based on measurement of the intensity of the emitted characteristic radiation by the elements of the sample, after being properly excited. One of the modalities of this technique is the total reflection x-ray fluorescence (TXRF). In TXRF, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample-support interface. Thus, there is a minimum angle of incidence that there is no refracted beam and all the incident radiation undergoes total reflection. As it is implemented in very small samples, in a film format, self-absorption effects should not very relevant. In this study, we evaluated the feasibility of using code MCNPX (Monte Carlo N - Particle eXtended), to simulate a measure implemented by the TXRF technique. In this way, it was verified the quality of response of a system by TXRF spectroscopy using synchrotron radiation as excitation beam for a simple setup, by retrieving the characteristic energies and the concentrations of the elements in the sample. The steps of data processing, after obtaining the excitation spectra, were the same as in a real experiment and included the obtaining of the sensitivity curve for the simulated system. The agreement between the theoretical and simulated values of Ka characteristic energies for different elements was lower than 1 % .The obtained concentration of the elements of the sample had high relatively errors ( between 6 and 60 % ) due mainly to lack of knowing about some realistic physical parameters of the sample , such as density . In this way, this result does not preclude the use of MCNPX code for this type of application

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Reference materials (RM) are required for quantitative analyses and their successful use is associated with the degree of homogeneity, and the traceability and confidence limits of the values established by characterisation. During the production of a RM, the chemical characterisation can only commence after it has been demonstrated that the material has the required level of homogeneity. Here we describe the preparation of BRP-1, a proposed geochemical reference material, and the results of the tests to evaluate its degree of homogeneity between and within bottles. BRP-1 is the first of two geochemical RM being produced by Brazilian institutions in collaboration with the United States Geological Survey (USGS) and the International Association of Geoanalysts (IAG). Two test portions of twenty bottles of BRP-1 were analysed by wavelength dispersive-XRF spectrometry and major, minor and eighteen trace elements were determined. The results show that for most of the investigated elements, the units of BRP-1 were homogeneous at conditions approximately three times more rigorous than those strived for by the test of sufficient homogeneity. Furthermore, the within bottle homogeneity of BRP-1 was evaluated using small beam (1 mm(2)) synchrotron radiation XRF spectrometry and, for comparison, the USGS reference materials BCR-2 and GSP-2 were also evaluated. From our data, it has been possible to assign representative minimum masses for some major constituents (1 mg) and for some trace elements (1-13 mg), except Zr in GSP-2, for which test portions of 74 mg are recommended.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Keloids are considered to be benign hyperproliferative growths of dense fibrous tissue and overabundant deposition of disorganized, thick, hyalinized collagen that result from an abnormal tissue response to cutaneous injury. Keloids do not have a specific cause, although genetic predisposition is heavily implicated. We present a case report of a patient with an earlobe keloid that was treated with carbon dioxide laser radiation (CO2) with an 0.8-mm focus, 7 W, a power density of 2.5 W/cm(2), in a continuous mode. The patient was seen for follow-up 6 months later. An intact hole for placement of an earring was observed with a very good esthetic and functional result.