99 resultados para LED grow lights
Resumo:
Aims and objectives: The behavior of polymer-matrix composite is dependent on the degree of conversion. The aim of this study was to evaluate the degree of conversion of two resin cements following storage at 37°C immediately, 24 and 48 hours, and 7 days after light-curing by FTIR analysis. Materials and methods: The specimens were made in a metallic mold and cured with blue LED with power density of 500 mW/cm2 for 30 seconds. The specimens were pulverized, pressed with KBr and analyzed with FTIR following storage times. Statistical analysis used: ANOVA (two-way) and Tukey's post hoc. Results: To the polymer-matrix composites between 24 and 48 hours does not show a significant increase (p > 0.05), however, the highest values were found after 7 days. Conclusion: The polymer-matrix composites used in this study showed similarity on the degree of conversion and increased of according to the time of storage.
Resumo:
The aim of this study was to evaluate the effects of different light-curing units and resin cement curing types on the bond durability of a feldspathic ceramic bonded to dentin. The crowns of 40 human molars were sectioned, exposing the dentin. Forty ceramic blocks of VITA VM7 were produced according to the manufacturer's recommendations. The ceramic surface was etched with 10% hydrofluoric acid/60s and silanized. The dentin was treated with37% phosphoric acid/15s, and the adhesive was applied. The ceramic blocks were divided and cemented to dentin according to resin cement/RC curing type(dual-and photocured), light-curing unit (halogen light/QTH and LED), and storage conditions (dry and storage/150 days + 12,000 cycles/thermocycling). All blocks were stored in distilled water (37°C/24h) and sectioned (n = 10): G1-QTH + RC Photo, G2-QTH + RC Dual, G3-LED + RC Photo, G4-LED + RC Dual. Groups G5, G6, G7, and G8 were obtained exactly as G1 through G4, respectively, and then stored and thermocycled. Microtensile bond strength tests were performed (EMIC), and data were statistically analyzed by ANOVA and Tukey's test (5%). The bond strength values (MPa) were: G1-12.95 (6.40)ab; G2-12.02 (4.59)ab; G3-13.09 (5.62)ab; G4-15.96 (6.32)a; G5-6.22 (5.90)c; G6-9.48 (5.99)bc; G7-12.78 (11.30)ab; and G8-8.34 (5.98)bc. The same superscript letters indicate no significant differences. Different light-curing units affected the bond strength betweenceramic cemented to dentin when the photocured cement was used, and only after aging (LED>QTH). There was no difference between the effects of dual-and photo-cured resin-luting agents on the microtensile bond strength of the cement used in this study.
Resumo:
The aim of this study was to evaluate the compressive strength of microhybrid (Filtek™ Z250) and nanofilled (Filtek™ Supreme XT) composite resins photo-activated with two different light guide tips, fiber optic and polymer, coupled with one LED. The power density was 653 mW cm -2 when using the fiber optic light tip and 596 mW cm-2 with the polymer. After storage in distilled water at 37 ± 2 °C for seven days, the samples were subjected to mechanical testing of compressive strength in an EMIC universal mechanical testing machine with a load cell of 5 kN and speed of 0.5 mm min-1. The statistical analysis was performed using ANOVA with a confidence interval of 95% and Tamhane's test. The results showed that the mean values of compressive strength were not influenced by the different light tips (p > 0.05). However, a statistical difference was observed (p < 0.001) between the microhybrid composite resin photo-activated with the fiber optic light tip and the nanofilled composite resin. Based on these results, it can be concluded that microhybrid composite resin photo-activated with the fiber optic light tip showed better results than nanofilled, regardless of the tip used, and the type of the light tip did not influence the compressive strength of either composite. Thus, the presented results suggest that both the fiber optic and polymer light guide tips provide adequate compressive strength to be used to make restorations. However, the fiber optic light tip associated with microhybrid composite resin may be an interesting option for restorations mainly in posterior teeth. © 2013 Astro Ltd.
Resumo:
Studies to determine suitable levels of intensification are essential for developing sustainable aquaculture. The objective of this study was to evaluate the quality of effluents discharged from ponds stocked with 10 (D10), 20 (D20), 40 (D40), and 80 (D80) postlarvae of Macrobrachium amazonicum/m2. Intake and effluent water samples were taken throughout a 5.5-mo grow-out cycle. In that study, twelve 0.01-ha earthen ponds were stocked postlarvae with 0.01g. Average water exchange rate was 15%/d; water was discharged from the bottom of the ponds. Prawns were fed a commercial feed with 38% crude protein according to their biomass (3-10%) and the concentration of dissolved oxygen (DO). In our research, temperature, turbidity, total suspended solids, conductivity, DO, pH, biochemical oxygen demand (BOD), chemical oxygen demand (COD), N-ammonia, N-nitrite, N-nitrate, N-Kjeldahl nitrogen, total phosphorus, and soluble orthophosphate were measured every 15d throughout the experiment in the early morning (0630 to 0730h). Turbidity was lower in D10 than in D20 and D40 and total phosphorus was higher in D80 than in D10 and D20. An analysis of principal components comparing treatments and intake water showed three groups: intake, D10 and a cluster of D20, D40, and D80. On the basis of the water characteristics found in our study it appears that the farming of M. amazonicum is likely to have a low environmental impact, at least up to a stocking density of 80prawns/m2. © by the World Aquaculture Society 2013.
Resumo:
The study evaluated the effectiveness and the sensitivity of in-office tooth bleaching with the use of a hybrid photo-activation system composed by LEDs and lasers. 40 patients, both genders, aged 18 through 25 years, were randomly distributed into two treatment groups: group I, 35% hydrogen peroxide, with a total bleaching time of 135 min divided into three sessions, and group II, 35% hydrogen peroxide and photo-thermal catalysis by an LED-laser system (300 mW cm-2), for a total bleaching time of 72 min divided into three sessions. The treatment efficiency was measured by reflectance spectroscopy and sensitivity by a visual analog scale (VAS). The final luminosity value (ΔL), color variation (ΔE) and sensitivity (S) resulting from the treatments were analyzed by the generalized estimating equations method (GEEs), and Bonferroni post hoc multiple comparisons at 5% significance. The two groups presented similar colors (ΔE) and luminosities (ΔL) after treatment. Group I presented a greater sensitivity index (37.6 ± 5.9%) compared to group II (11.1 ± 3.3%), statistically significant at p < 0.05. The use of LED-laser hybrid light, as a catalyst of the bleaching agents, showed a significant decrease of provoked tooth sensitivity and a treatment time reduced by 53%, with the same aesthetic results as without a light source. © 2013 Astro Ltd.
Photodynamic potential of curcumin and blue LED against streptococcus mutans in a planktonic culture
Resumo:
Background: The photodynamic therapy (PDT) involves the use of light of specific wavelength to activate a nontoxic photosensitizing agent or dye in the presence of oxygen for eradication of target cells. In dentistry, this therapy is used to suppress the growth of microorganisms involved directly with dental decay and periodontitis process. There are evidences that curcumin dye is able to control microbial activity when illuminated with specific wavelength. The purpose of this study was to evaluate the in vitro efficacy of PDT using curcumin dye (Cur-C) in combination with a blue LED (L) device on a planktonic model of Streptococcus mutans ( S. mutans). Methods: Suspensions (0.5mL) containing S. mutans at 1×107CFUmL-1 were prepared and divided into 4 groups: Group C-L- (control: no treatment and 1 experimental condition), Group C+L- (curcumin at 3 different concentrations: 2000; 4000 and 8000μM and 3 experimental conditions), Group C-L+ (LED at 3 different dosages: 24, 48 and 72Jcm-2 and 3 experimental conditions), and Group C+L+ (PDT group: curcumin at respective concentrations combined to LED dosages and 9 experimental conditions). Samples of each experimental condition were cultured in Petri dishes of BHI agar. Incubation in micro-aerophilia at 37°C for 48h was performed for subsequent visual counting of CFU/mL. Data were transformed into log10 and analyzed by two-way ANOVA and Tukey's test at p<0.05. Results: Group C. +. L+, in specific experimental conditions, demonstrated a log bacterial reduction 70% higher than Group C. -. L-. Both groups C. -. L+ and C. +. L- presented a slight decrease in log bacterial counting. Conclusion: This in vitro method was able to reduce the number of S. mutans in a planktonic suspension. © 2013 Elsevier B.V.
Resumo:
This study investigated the physicochemical properties of the new formulation of the glass ionomer cements through hardness test and degree of conversion by infrared spectroscopy (FTIR). Forty specimens (n = 40) were made in a metallic mold (4 mm diameter × 2 mm thickness) with two resin-modified glass ionomer cements, Vitrebond™ and Vitrebond™ Plus (3M/ ESPE). Each specimen was light cured with blue LED with power density of 500 mW/cm2during 30 s. Immediately after light curing, 24h, 48h and 7 days the hardness and degree of conversion was determined. The Vickers hardness was performed by the MMT-3 microhardness tester using load of 50 gm force for 30 seconds. For degree of conversion, the specimens were pulverized, pressed with KBr and analyzed with FT-IR (Nexus 470). The statistical analysis of the data by ANOVA showed that the Vitrebond™ and Vitrebond™ Plus were no difference significant between the same storage times (p > 0.05). For degree of conversion, the Vitrebond™ and Vitrebond™ Plus were statistically different in all storage times after light curing. The Vitrebond™ showed higher values than Vitrebond™ Plus (p < 0.05). The performance of Vitrebond™ had greater results for degree of conversion than Vitrebond™ Plus. The correlation between hardness and degree of conversion was no evidence in this study.
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Educação - IBRC
Resumo:
Pós-graduação em Educação - FCT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)