65 resultados para Interpolation and function approximation (numerical analysis)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Platelet function and plasma fibrinogen levels were evaluated in 14 patients, 10 males and 4 females, aged 13-59 years bitten by Bothrops genus snakes. There was a statistical difference (p < 0.05) among plasma fibrinogen levels evaluated 24 and 48 hours after envenomation. There was a tendency towards normalization after 48 hours of treatment. The low platelet number was clear in 24-48 hour evaluations with a tendency towards normalization after 48 hours of treatment (p < 0.05). When platelet function was stimulated by collagen and epinephrine, it appeared to be within normal values. On the other hand, when it was stimulated by adenosine diphosphate (ADP), platelet function was hypoaggregated by a single micromol concentration until 48 hours after treatment. At a 3 micromol concentration, there were alterations only before specific treatment (p < 0.05). Fibrinogen levels and fibrin degradation product (FDP) levels appeared to be altered in 83.33% of patients evaluated. The authors suggest that platelet hypoaggregation is related to decreased fibrinogen and increased FDP levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main purpose of this paper is to investigate theoretically and experimentally the use of family of Polynomial Powers of the Sigmoid (PPS) Function Networks applied in speech signal representation and function approximation. This paper carries out practical investigations in terms of approximation fitness (LSE), time consuming (CPU Time), computational complexity (FLOP) and representation power (Number of Activation Function) for different PPS activation functions. We expected that different activation functions can provide performance variations and further investigations will guide us towards a class of mappings associating the best activation function to solve a class of problems under certain criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Large single crystals have been obtained of SIII-SPIII, a phospholipase A2 from the venom of Bothrops jararacussu. The crystals belong to the orthorhombic system space group C222, and diffract X-rays to a resolution of 1.9 Å. Preliminary analysis reveals the presence of one molecule in the crystallographic asymmetric unit. The crystal structure is currently being determined using molecular replacement techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In cases of delayed tooth replantation, non-vital periodontal ligament remnants have been removed with sodium hypochlorite in an attempt to control root resorption. Nevertheless, reports of its irritating potential in contact with the alveolar connective tissue have been described. Therefore, this study evaluated the healing process on delayed replantation of rat teeth, after periodontal ligament removal by different treatment modalities. Twenty-four rats, assigned to 3 groups (n=8), had their upper right incisor extracted and left on the workbench for desiccation during 60 min. Afterwards, the teeth in group I were immersed in saline for 2 min. In group II, root surfaces were scrubbed with gauze soaked in saline for 2 min; and in group III, scrubbing was done with gauze soaked in 1% sodium hypochlorite solution. Thereafter, root surfaces were etched with 37% phosphoric acid and immersed in 2% acidulate-phosphate sodium fluoride solution, at pH 5.5. Root canals were filled with a calcium hydroxide-based paste and the teeth were replanted. The animals were sacrificed 60 days postoperatively and the pieces containing the replanted teeth were processed and paraffin- embedded. Semi-serial transversally sections were obtained from the middle third of the root and stained with hematoxylin and eosin for histomorphometric analysis. Data were analyzed statistically using Kruskal-Wallis and Dunn's tests. The results showed that root structure and cementum extension were more affected by resorption in group III (p<0.05). All groups were affected by root resorption but the treatment performed in group III was the least effective for its control. The treatment accomplished in groups I and II yielded similar results to each other.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is well known that the microcrack density is a fundamental parameter in hard chromium electroplating. The chemical and mechanical properties of this coating are widely dependent on its microcrack density. In this paper a simple image analysis procedure to determine microcrack density is presented in order to demonstrate it as a fundamental tool to estimate the fatigue, corrosion and wear behavior, as well as the residual stress field of a coated component. For this purpose, the image analysis procedure was carried out on two kinds of hard chromium plating - one called accelerated (high velocity of deposition and fluoride-free) and the other conventional (with fluoride). The coatings were applied on samples of AISI 4340 aeronautical steel, which is widely used in aircraft landing gear components. To characterize the practical significance of this study, the microcrack density results were related to the fatigue, wear and corrosion behavior from previous study and to the residual stress field in the coatings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multipulse rectifier topologies based on autoconnections, or differential connections, are more and more applied as interface stages between the mains and power converters. These topologies mitigate many low-order current harmonics in the utility, reducing the THD (total harmonic distortion) and increasing the power factor. This paper presents a mathematical model based on phasor diagrams, that results in a single expression able to unify all differential topologies connections (Delta and Wye), for both step-up or step-down autotransformers, for 12 and 18-pulse AC-DC converters. The proposed family of converters can be designed for any relationship between the input voltage and the load voltage. An immediate application would be the retrofit, i.e. to replace a conventional rectifier with poor quality of the processed energy by the 12 or 18 pulses rectifier with Wye or Delta-differential connection. The design procedure, simple and fast, is developed and tested for a prototype rating 6 kW and 250 V on the DC load © 2010 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This article showed a clinical case of an elderly who was treated with a collarless metal-ceramic fixed partial denture and acrylic removable gingival prosthesis to recover the esthetics in the maxillary anterior region. The association of a metal-ceramic fixed denture and gingival prosthesis was an excellent alternative in cases when surgical procedures are contraindicated. © 2012 Japan Prosthodontic Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate commercially pure titanium implant surfaces modified by laser beam (LS) and LS associated with sodium silicate (SS) deposition, and compare them with machined surface (MS) and dual acid-etching surfaces (AS) modified. Topographic characterization was performed by scanning electron microscopy-X-ray energy dispersive spectroscopy (SEM-EDX), and by mean roughness measurement before surgery. Thirty rabbits received 60 implants in their right and left tibias. One implant of each surface in each tibia. The implants were removed by reverse torque for vivo biomechanical analysis at 30, 60, and 90 days postoperative. In addition, the surface of the implants removed at 30 days postoperative was analyzed by SEM-EDX. The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of LS and SS were statistically higher than AS and MS. At 30 days, values removal torque LS and SS groups showed a statistically significant difference (p < 0.05) when compared with MS and AS. At 60 days, groups LS and SS showed statistically significant difference (p < 0.05) when compared with MS. At 90 days, only group SS presented statistically higher (p < 0.05) in comparison with MS. The authors can conclude that physical chemistry properties and topographical of LS and SS implants increases bone-implant interaction and provides higher degree of osseointegration when compared with MS and AS. © 2012 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an experimental research on the use of eddy current testing (ECT) and artificial neural networks (ANNs) in order to identify the gauge and position of steel bars immersed in concrete structures. The paper presents details of the ECT probe and concrete specimens constructed for the tests, and a study about the influence of the concrete on the values of measured voltages. After this, new measurements were done with a greater number of specimens, simulating a field condition and the results were used to generate training and validation vectors for multilayer perceptron ANNs. The results show a high percentage of correct identification with respect to both, the gauge of the bar and of the thickness of the concrete cover. © 2013 Copyright Taylor and Francis Group, LLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To describe the technique of deep anterior lamellar keratoplasty (DALK) with Descemet's membrane (DM) exposure in horse eyes. Also, to compare the efficacy and safety of viscodissection and big-bubble techniques for DALK. Animals studied Thirty-four ex vivo horse eyes. Procedure Deep anterior lamellar keratoplasty was performed in 34 ex vivo horse eyes. Two groups (Group V - viscodissection - 2% sodium hyaluronate; Group A - air - big-bubble) of 17 eyes were studied. Other than the substance used, the surgical technique was similar for both groups. Nonperforated eyes were submitted for light microscopic histologic evaluation and scanning electron microscopic (SEM) analysis. Results Group V - Perforations occurred in 18% of the eyes during surgery. Light microscopy revealed exposure of DM in 28% of the eyes with mean thickness of the remaining stroma being 70.4μm. Group A - Perforations occurred in 42% of the eyes. Light microscopy revealed exposure of DM in 60% of the eyes with mean thickness of the remaining stroma being 23.3μm. No significant differences in safety, efficacy and thickness of the remaining stroma (including all eyes or excluding those with DM exposure) were observed. SEM of the surgical site revealed a more even surface in those eyes with DM exposure compared to eyes with thicker remaining stroma in both groups. Conclusions We describe two DALK techniques (viscodissection and big-bubble) for use in horses. No significant differences in safety, efficacy and thickness of the remaining stroma were observed. However, a nonsignificant trend toward the big-bubble technique being more efficacious but less safe was observed. © 2012 American College of Veterinary Ophthalmologists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contents: Strategic supplementation of P4 may be used to increase conception rates in cattle, but timing of supplementation in relation to ovulation, mass of supplementary P4 and formulation of the P4-containing supplement has not been determined for beef cattle. Effects of supplementation of long-acting progesterone (P4) on Days 2 or 3 post-ovulation on development, function and regression of corpus luteum (CL) were studied in beef cattle. Cows were synchronized with an oestradiol/P4-based protocol and treated with 150 or 300 mg of long-acting P4 on Day 2 or 3 post-ovulation (6-7 cows/group). Colour-doppler ultrasound scanning and blood sample collection were performed from Day 2-21.5. Plasma P4 concentrations were greater (p < 0.05) from Day 2.5-5.5 in the Day 2-treated groups and from Day 3.5-5.5 in the Day 3-treated cows than in the control group. CL area and blood flow during Day 2-8.5 did not differ (p > 0.05) among groups, suggesting no effect of P4 treatment on luteal development. The frequency of cows that began luteolysis before Day 15 was greater (p < 0.04) in cows treated with 300 mg than in the controls, but there were no differences between non-treated and 150 mg-treated cows. The interval from pre-treatment ovulation to functional and structural luteolysis was shorter (p < 0.01) in the combined P4-treated groups than in the control cows. In conclusion, was showed for the first time that long-acting P4 supplementation on Day 2 or 3 post-ovulation increases P4 concentrations for ≥3 day, has no effect on luteal development, but anticipates the beginning of luteolysis in beef cattle. © 2013 Blackwell Verlag GmbH.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)