132 resultados para Heart Function Tests
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Neural networks and wavelet transform have been recently seen as attractive tools for developing eficient solutions for many real world problems in function approximation. Function approximation is a very important task in environments where computation has to be based on extracting information from data samples in real world processes. So, mathematical model is a very important tool to guarantee the development of the neural network area. In this article we will introduce one series of mathematical demonstrations that guarantee the wavelets properties for the PPS functions. As application, we will show the use of PPS-wavelets in pattern recognition problems of handwritten digit through function approximation techniques.
Resumo:
The running velocities associated to lactate minimum (V-lm), heart rate deflection (V-HRd), critical velocity (CV), 3000 M (V-3000) and 10000 m performance (V-10km) were compared. Additionally the ability of V-lm and VHRd on identifying sustainable velocities was investigated.Methods. Twenty runners (28.5 +/- 5.9 y) performed 1) 3000 m running test for V3000; 2) an all-out 500 in sprint followed by 6x800 m incremental bouts with blood lactate ([lac]) measurements for V-lm; 3) a continuous velocity-incremented test with heart rate measurements at each 200 m for V-HRd; 4) participants attempted to 30 min of endurance test both at V-lm(ETVlm) and V-HRd(ETVHRd). Additionally, the distance-time and velocity-1/time relationships produced CV by 2 (500 m and 3000 m) or 3 predictive trials (500 m, 3000 m and distance reached before exhaustion during ETVHRd), and a 10 km race was recorded for V-10km.Results. The CV identified by different methods did not differ to each other. The results (m(.)min(-1)) revealed that V-.(lm) (281 +/- 14.8)< CV (292.1 +/- 17.5)=V-10km (291.7 +/- 19.3)< V-HRd (300.8 +/- 18.7)=V-3000 (304 +/- 17.5) with high correlation among parameters (P < 0.001). During ETVlm participants completed 30 min of running while on the ETVHRd they lasted only 12.5 +/- 8.2 min with increasing [lac].Conclusion. We evidenced that CV and Vim track-protocols are valid for running evaluation and performance prediction and the parameters studied have different significance. The V-lm reflects the moderate-high intensity domain (below CV), can be sustained without [lac] accumulation and may be used for long-term exercise while the V-HRd overestimates a running intensity that can be sustained for long-time. Additionally, V-3000 and V-HRd reflect the severe intensity domain (above CV).
Resumo:
Exercise capacity and quality of life (QOL) are important outcome predictors in patients with systolic heart failure (HF), independent of left ventricular (LV) ejection fraction (LVEF). LV diastolic function has been shown to be a better predictor of aerobic exercise capacity in patients with systolic dysfunction and a New York Heart Association (NYHA) classification >II. We hypothesized that the currently used index of diastolic function E/e' is associated with exercise capacity and QOL, even in optimally treated HF patients with reduced LVEF. This prospective study included 44 consecutive patients aged 55±11 years (27 men and 17 women), with LVEF,0.50 and NYHA functional class I-III, receiving optimal pharmacological treatment and in a stable clinical condition, as shown by the absence of dyspnea exacerbation for at least 3 months. All patients had conventional transthoracic echocardiography and answered the Minnesota Living with HF Questionnaire, followed by the 6-min walk test (6MWT). In a multivariable model with 6MWT as the dependent variable, age and E/e' explained 27% of the walked distance in 6MWT (P=0.002; multivariate regression analysis). No association was found between walk distance and LVEF or mitral annulus systolic velocity. Only normalized left atrium volume, a sensitive index of diastolic function, was associated with decreased QOL. Despite the small number of patients included, this study offers evidence that diastolic function is associated with physical capacity and QOL and should be considered along with ejection fraction in patients with compensated systolic HF.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective The present study aimed to examine the reproducibility of heart rate (HR) and rating of perceived exertion (RPE) values obtained during different incremental treadmill tests. Equipment and methods Twenty male, recreational, endurance-trained runners (10-km running pace: 10–15 km·h−1) performed, in a counterbalanced order, three continuous incremental exercise tests with different speed increments (0.5 km·h−1, 1 km·h−1 and 2 km·h−1). Thereafter, each participant performed the three tests again, maintaining the same order as before. The reproducibility of the HR and RPE values were analyzed for all protocols during submaximal intensities (8, 10, 12, and 14 km·h−1). In addition, it was examined the reproducibility of maximal HR (HRmax) and peak RPE (RPEpeak). Results The variability of both the HR and RPE values showed a tendency to decrease over the stages during the incremental test and was not or slightly influenced by the incremental test design. The HR at 14 km·h−1 and HRmax presented the highest reproducibility (CV < 2%). In contrast, the submaximal RPE values showed higher variability indices (i.e., CV > 5.0%). In conclusion, the HR values were highly reproducible during the stages of the incremental test, in contrast to the RPE values that presented limited reproducibility.
Resumo:
The effects of adrenergic stimulation on mean circulatory filling pressure (MCFP), central venous pressure (P-CV) and stroke volume (Vs), as well as the effects of altered MCFP through changes of blood volume were investigated in rattlesnakes (Crotalus durissus). MCFP is an estimate of the upstream pressure driving blood towards the heart and is determined by blood volume and the activity of the smooth muscle cells in the veins (venous tone). MCFP can be determined as the plateau in P-CV during a total occlusion of blood flow from the heart.Vs decreased significantly when MCFP was lowered by reducing blood volume in anaesthetised snakes, whereas increased MCFP through infusion of blood (up to 3 ml kg(-1)) only led to a small rise in Vs. Thus, it seems that end-diastolic volume is not affected by an elevated MCFP in rattlesnakes. To investigate adrenergic regulation on venous tone, adrenaline as well as phenylephrine and isoproterenol (alpha- and beta-adrenergic agonists, respectively) were infused as bolus injections (2 and 10 mu g kg(-1)). Adrenaline and phenylephrine caused large increases in MCFP and P-CV, whereas isoproterenol decreased both parameters. This was also the case in fully recovered snakes. Therefore, adrenaline affects venous tone through both alpha- and beta-adrenergic receptors, but the alpha-adrenergic receptor dominates at the dosages used in the present study. Injection of the nitric oxide donor SNP caused a significant decrease in P-CV and MCFP. Thus, nitric oxide seems to affect venous tone.
Resumo:
Background: It was reported that autonomic nervous system function is altered in subjects with chronic obstructive pulmonary disease (COPD). We evaluated short-and long-term fractal exponents of heart rate variability (HRV) in COPD subjects.Patients and methods: We analyzed data from 30 volunteers, who were divided into two groups according to spirometric values: COPD (n = 15) and control (n = 15). For analysis of HRV indices, HRV was recorded beat by beat with the volunteers in the supine position for 30 minutes. We analyzed the linear indices in the time (SDNN [standard deviation of normal to normal] and RMSSD [root-mean square of differences]) and frequency domains (low frequency [LF], high frequency [HF], and LF/HF), and the short-and long-term fractal exponents were obtained by detrended fluctuation analysis. We considered P < 0.05 to be a significant difference.Results: COPD patients presented reduced levels of all linear exponents and decreased short-term fractal exponent (alpha-1: 0.899 +/- 0.18 versus 1.025 +/- 0.09, P = 0.026). There was no significant difference between COPD and control groups in alpha-2 and alpha-1/alpha-2 ratio.Conclusion: COPD subjects present reduced short-term fractal correlation properties of HRV, which indicates that this index can be used for risk stratification, assessment of systemic disease manifestations, and therapeutic procedures to monitor those patients.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The search for better performance in the structural systems has been taken to more refined models, involving the analysis of a growing number of details, which should be correctly formulated aiming at defining a representative model of the real system. Representative models demand a great detailing of the project and search for new techniques of evaluation and analysis. Model updating is one of this technologies, it can be used to improve the predictive capabilities of computer-based models. This paper presents a FRF-based finite element model updating procedure whose the updating variables are physical parameters of the model. It includes the damping effects in the updating procedure assuming proportional and none proportional damping mechanism. The updating parameters are defined at an element level or macro regions of the model. So, the parameters are adjusted locally, facilitating the physical interpretation of the adjusting of the model. Different tests for simulated and experimental data are discussed aiming at defining the characteristics and potentialities of the methodology.