256 resultados para Graphite foil


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to their high hardness and wear resistance Si3N4 based ceramics are one of the most suitable cutting tool materials for machining hardened materials. Therefore, their high degree of brittleness usually leads to inconsistent results and sudden catastrophic failures. Improvement of the functional properties these tools and reduction of the ecological threats may be accomplished by employing the technology of putting down hard coatings on tools in the state-of-the-art PVD processes, mostly by improvement of the tribological contact conditions in the cutting zone and by eliminating the cutting fluids. However in this paper was used a Si3N4 based cutting tool commercial with a layer TiN coating. In this investigation, the performance of TiN coating was assessed on turning used to machine an automotive grade compacted graphite iron. As part of the study were used to characterise the performance of cutting tool, flank wear, temperature and roughness. The results showed that the layer TiN coating failed to dry compacted graphite iron under aggressive machining conditions. However, using the measurement of flank wear technique, the average tool life of was increased by VC=160 m/min.The latter was also observed using a toolmakers microscope and scanning electron microscopy (SEM).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Copper Pentacyanonitrosylferrate (NCuNP) nanoparticles were prepared in formamide solvent. The material was characterized by Infrared (FTIR), X-Ray Diffraction (XRD) and Ultraviolet-Visible (UV-Vis) Spectroscopy. The Cyclic Voltammogram (CV) the modified graphite paste electrode with NCuNP exhibits two redox couples with (Eθ,)1 = 0.29 and (E θ,)2 = 0.86 V attribute at Cu(I)/Cu (II) and Fe(II)(CN)5NO/Fe(III)(CN) 5NO processes, respectively (KCl = 1.0 mol L-1; v = 20 mV s-1). The redox couple with (Eθ,)2 presents an electrocatalytic response for sulfite. The modified graphite paste electrode gives a linear response of 7.0 × 10-4 to 3.0 × 10-2 mol L-1 (r = 0.998), for sulfite determination with Detection Limit (DL) of 1.76 × 10-3 mol L-1 and an amperometric sensitivity of 3.38 mA/mol L-1 and relative standard desviations ± 3% (n=3). ©The Electrochemical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The automatic characterization of particles in metallographic images has been paramount, mainly because of the importance of quantifying such microstructures in order to assess the mechanical properties of materials common used in industry. This automated characterization may avoid problems related with fatigue and possible measurement errors. In this paper, computer techniques are used and assessed towards the accomplishment of this crucial industrial goal in an efficient and robust manner. Hence, the use of the most actively pursued machine learning classification techniques. In particularity, Support Vector Machine, Bayesian and Optimum-Path Forest based classifiers, and also the Otsu's method, which is commonly used in computer imaging to binarize automatically simply images and used here to demonstrated the need for more complex methods, are evaluated in the characterization of graphite particles in metallographic images. The statistical based analysis performed confirmed that these computer techniques are efficient solutions to accomplish the aimed characterization. Additionally, the Optimum-Path Forest based classifier demonstrated an overall superior performance, both in terms of accuracy and speed. © 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental investigations were carried out using a Nd:YAG laser operating in pulsed mode for welding a lap joint between thin foil and thick sheet. The pulse energy was varied from 1.5 to 3.0 J at increments of 0.25 J with a 4 ms pulse duration. The base material used for this study was AISI 316L foils with 100 mu m thickness and sheet with 3.0 mm thickness. The welds were analysed by optical and electronic microscopy, tensile shear tests and micro hardness. The results indicate that pulse energy control is of considerable importance to join thin foil and thick sheet with good quality. The ultimate tensile strength of the welded joints increased at first and then decreased as the pulse energy increased. The process appeared to be very sensitive to the gap between couples. Large voids delimited by the molten zone boundary were observed in joints welded with high pulse energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the absolute values of the c ̂-axis resistivity obtained from conduction electron spin resonance (CESR) experiments at various temperatures for a graphite-AlCl3 stage 2 compound. The agreement with d.c. measurements is quite good. The temperature dependence of the c ̂-axis resistivity previously obtained from CESR for graphite-AlCl3 is revised. © 1990.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The L-dopa is the immediate precursor of the neurotransmitter dopamine. Unlike dopamine, L-dopa easily enters the central nervous system and is used in the treatment of Parkinson's disease. A sensitive and selective method is presented for the voltammetric determination of L-dopa in pharmaceutical formulations using a carbon paste electrode modified with trinuclear ruthenium ammine complex [(NH3)(5)Ru-III-O-Ru-IV(NH3)(4)-O-Ru-III(NH3)(5)](6+) (Ru-red) incorporated in NaY zeolite. The parameters which influence on the electrode response (paste composition, potential scan rate, pH and interference) were also investigated. The optimum conditions were found to an electrode composition (m/m) of 25% zeolite containing 6.7% Ru, 50% graphite and 25% mineral oil in acetate buffer at pH 4.8. Voltammetric peak currents showed a linear response for L-dopa concentration in the range between 1.2 x 10(-4) and 1.0 x 10(-2) Mol l(-1) (r = 0.9988) with a detection limit of 8.5 x 10(-5) mol l(-1). The variation coefficient for a 1.0 x 10(-3) mol l(-1) L-dopa (n = 10) was 5.5%. The results obtained for L-dopa in pharmaceutical formulations (tablet) was in agreement with compared official method. In conclusion, this study has illustrated that the proposed electrode modified with Ru-red incorporated zeolite is suitable valuable for selective measurements of L-dopa. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electroanalytical determination of isoprenaline in pharmaceutical preparations of a homemade carbon paste electrode modified with copper(II) hexacyanoferrate(III) (CuHCF) was studied by cyclic voltammetry. Several parameters were studied for the optimization of the sensor such as electrode composition, electrolytic solution, pH effect, potential scan rate and interferences in potential. The optimum conditions were found in an electrode composition (in mass) of 15% CuHCF, 60% graphite and 25% mineral oil in 0.5 mol l(-1) acetate buffer solution at pH 6.0. The analytical curve for isoprenaline was linear in the concentration range from 1.96 x 10(-4) to 1.07 x 10(-3) mol l(-1) with a detection limit of 8.0 x 10(-5) mol l(-1). The relative standard deviation was 1.2% for 1.96 x 10(-4) mol l(-1) isoprenaline solution (n=5). The procedure was successfully applied to the determination of isoprenaline in pharmaceutical preparations; the CuHCF modified carbon paste electrode gave comparable results to those results obtained using a UV spectrophotometric method. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Membrane integrity, as measured by electrical conductivity (EC), is suggested as an indicator of seed vigor in soybean [Glycine max (L.) Merrill] seeds. This study evaluated the effect of storage time and temperature on EC of six soybean seed lots (two lots each of high, medium and low vigor). All seed lots were adjusted to 120 g kg(-1) seed moisture, sealed in aluminum foil packets and placed in storage at 10 and 20 degreesC or stored unsealed in multi-wall paper bags in warehouse (WH) conditions at Lexington, KY, USA for 486 days. Four of the six seed lots were also stored unsealed at 10 degreesC. All seed lots were sampled at 3-month intervals and evaluated for seed moisture (SMC), standard germination (SG) and vigor [accelerated aging (AA) and EC]. After 91 and 204 days in storage, samples initially stored at 20 degreesC and WH were moved to 10 degreesC and sampled at the same intervals. Seed moisture content for unsealed samples equilibrated at 107 g kg(-1) (+/-9 g kg(-1)) in both the WH and 10 degreesC environments. No change in SG occurred for seeds stored sealed (120 g kg(-1)) at 10 degreesC, except for the low vigor seed lots which declined significantly at the last sample date. The AA germination declined significantly for all, seed lots stored sealed at 10 degreesC, however the EC did not change during the same storage period. Seeds stored sealed at 20 degreesC and unsealed in the WH showed rapid declines in AA and SG and significant increases in EC. When these seeds were moved to 10 degreesC, however, the AA continued to decline while the EC remained at the same level (no significant change) for the remainder of the seed storage period. Thus whilst the AA declined in all environments, the EC only increased at higher temperatures (20 degreesC, WH) but showed little change during storage at 10 degreesC. Thus, precautions must be taken if using EC to measure soybean seed vigor following storage at 10 degreesC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Para avaliar procedimentos para a manutenção da umidade do substrato durante o teste de germinação de Brachiaria brizantha. Estudou-se o efeito da posição das caixas plásticas na câmara de germinação sobre a perda de água semanal, testando-se nove posições verticais (bandejas) e três posições horizontais (porta, meio e fundo do germinador). Foi também avaliado o efeito de procedimentos para manter a umidade do substrato, sobre a germinação, a perda de água semanal e o tempo despendido para a instalação do teste. Os procedimentos testados foram: (a) vedação da caixa plástica com vaselina, (b) vedação com saco plástico dobrado em quatro e colocado entre a tampa e a caixa, (c) colocação da caixa tampada dentro de saco plástico, (d) espuma sob o papel de germinação e (e) testemunha, caixa apenas tampada. Concluiu-se que a câmara de germinação promove a desidratação desigual do substrato conforme a posição das caixas; aquelas localizadas na primeira bandeja superior são as mais prejudicadas. Entre os procedimentos, a vedação com vaselina, a colocação da caixa dentro de saco plástico e a vedação com saco plástico dobrado em quatro entre a tampa e a caixa são eficientes na manutenção da umidade do substrato em taxas que não alteram os resultados do teste de germinação de B. brizantha; os dois últimos procedimentos são os mais rápidos e práticos, adaptando-se à rotina de um laboratório de análise de sementes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Teve-se o objetivo de avaliar as formas de se misturar o lubrificante sólido grafite nas sementes de milho, as dosagens e a influência desse na distribuição longitudinal e na germinação, em sementes sem e com tratamento fitossanitário, em mecanismo dosador com disco perfurado horizontal. Os fatores analisados foram: distribuição longitudinal das sementes (espaçamentos falhos, múltiplos e aceitáveis) e a porcentagem de germinação aos 7 e aos 14 dias após a instalação no germinador. Concluiu-se que o tratamento fitossanitário aumentou os espaçamentos falhos e múltiplos e reduziu os espaçamentos aceitáveis. O emprego de grafite reduziu os espaçamentos falhos e múltiplos e elevou os espaçamentos aceitáveis. A melhor forma de mistura do grafite ocorreu na máquina de tratamento fitossanitário de sementes. A distribuição longitudinal alcançou seu ponto ótimo com a dosagem de grafite de 3,37 g kg-1 de semente. As variáveis tratamento fitossanitário, mecanismo dosador e grafite não influíram na germinação das sementes de milho.