189 resultados para Fractal de Gosper


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Educação Matemática - IGCE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature indicated that the fractal analysis of heart rate variability (HRV) is related to the chaos theory. However, it is not clear if the both short and long-term fractal scaling exponents of HRV are reliable for short period analysis in women. We evaluated the association of the fractal exponents of HRV with the time and frequency domain and geometric indices of HRV. We evaluated 65 healthy women between 18 and 30 years old. HRV was analyzed with a minimal number of 256 RR intervals in the time (SDNN, RMSSD, NN50 and pNN50) and frequency (LF, HF and LF/HF ratio) domains, the geometric index were also analyzed (triangular indexRRtri, triangular interpolation of RR intervals-TINN and Poincaré plot-SD1, SD2 and SD1/SD2) as well as short and long-term fractal exponents (alpha-1 and alpha-2) of the detrended fluctuation analysis (DFA). No significant correlation was observed for alpha-2 exponent with all indices. There was significant correlation of the alpha-1 exponent with RMSSD, pNN50, SDNN/RMSSD, LF (nu), HF (nu and ms2 ), LF/HF ratio, SD1 and SD1/SD2 ratio. Our data does not indicate the alpha-2 exponent to be used for 256 RR intervals and we support the alpha-1 exponent to be used for HRV analysis in this condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fractal analysis of heart rate variability (HRV) has been associated to the chaos theory. We evaluated the association of the fractal exponents of HRV with the time and frequency domain and geometric indices of HRV for short period. HRV was analyzed with a minimal number of 256 RR intervals in the time (SDNN-standard deviation of normal-to-normal R-R intervals, pNN50-percentage of adjacent RR intervals with a difference of duration greater than 50ms and RMSSD-root-mean square of differences between adjacent normal RR intervals in a time interval) and frequency (LF-low frequency, HF-high frequency and LF/HF ratio) domains. The geometric indexes were also analyzed (RRtri-triangular index, TINN-triangular interpolation of RR intervals and Poincaré plot) as well as short and long-term fractal exponents (alpha-1 and alpha-2) of the detrended fluctuation analysis (DFA). We observed strong correlation of the alpha-1 exponent with RMSSD, pNN50, SDNN/RMSSD, LF (nu), HF (nu), LF/HF ratio, SD1 and SD1/Sd2 ratio. In conclusion, we suggest that the alpha-1 exponent could be applied for HRV analysis with a minimal number of 256 RR intervals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: We evaluated the effects of the PCM on the fractal analysis of the HRV in healthy women Method: We evaluated healthy women between 18 and 30 years old. HRV was analyzed in the time (SDNN, RMSSD, NN50 and pNN50) and frequency (LF, HF and LF/HF ratio) domains as well as short and long-term fractal exponents (alpha-1 and alpha-2) of the detrended fluctuation analysis (DFA). HRV was recorded at rest for ten minutes at seated rest and then the women quickly stood up from a seated position in up to three seconds and remained standing for 15 minutes. HRV was recorded at the following time: rest, 0–5 min, 5–10 min and 10–15 min during standing. Results: We observed decrease (p < 0.05) in the time-domain indices of HRV between seated and 10–15 minutes after the volunteer stood up. The LF (ms2) and HF (ms2) indices were also reduced (p < 0.05) at 10–15 minutes after the volunteer stood up compared to seated while the LF (nu) was increased at 5–10 min and 10–15 min (p < 0.05). The short-term alpha-1 exponent was increased (p < 0.05) at all moments investigated compared to seated. Increase in the properties of short-term fractal correlations of heart rate dynamics accompanied by a decrease in the parasympathetic modulation and global HRV was observed in response to the postural change maneuver. Conclusion: We suggest that fractal analysis of HRV is more sensitive than frequency and time-domain analysis of HRV during the postural change maneuver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fracture surfaces express the sequence of events of energy release due to crack propagation by linking the relief of the fracture to the loading stresses. This study aims to evaluate the heterogeneity of the critical zone for the advancement of the crack along its entire length in a thermoset composite carbon fiber and epoxy matrix, fractured in DCB testing (Double Cantilever Beam) and ENF (End-Notched Flexure). Investigations were made from image stacks obtained by optical reflection of extended depth from focus reconstruction. The program NIH Image J was used to obtain elevation map and fully focused images of the fracture surface, whose topographies were quantitatively analyzed. The monofractal behavior for DCB samples was assessed as being heterogeneous along the crack front and along the crack for all the conditionings. For the samples fractured in ENF test, there was a strong positive correlation to the natural condition, considering the fibers at 0° for the monofractal dimension and structural dimension (Df and Ds). For fibers at 90° to crack propagation, there was a moderate positive correlation for the textural dimension of natural condition. However, for the samples under ultraviolet condition and those subjected to thermal cycles, there was no correlation between the fractal dimension and fracture toughness in mode II

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the development of this graduate work of fractal fracture behavior, it is necessary to establish references for fractal analysis on fracture surfaces, evaluating, from tests of fracture tenacity on modes I, II and combined I / II, the behavior of fractures in fragile materials, on linear elastic regime. Fractures in the linear elastic regime are described by your fractal behavior by several researchers, especially Mecholsky JJ. The motivation of that present proposal stems from work done by the group and accepted for publication in the journal Materials Science and Engineering A (Horovistiz et al, 2010), where the model of Mecholsky could not be proven for fractures into grooved specimens for tests of diametric compression of titania on mode I. The general objective of this proposal is to quantify the distinguish surface regions formed by different mechanisms of fracture propagation in linear elastic regime in polymeric specimens (phenolic resin), relating tenacity, thickness of the specimens and fractal dimension. The analyzed fractures were obtained from SCB tests in mode I loading, and the acquisition of images taken using an optical reflection microscope and the surface topographies obtained by the extension focus method of reconstruction, calculating the values of fractal dimension with the use of maps of elevations. The fractal dimension was classified as monofractal dimension (Df), when the fracture is described by a single value, or texture size (Dt), which is a macroscopic analysis of the fracture, combined with the structural dimension (Ds), which is a microscopic analysis. The results showed that there is no clear relationship between tenacity, thickness and fractal values for the material investigated. On the other hand it is clear that the fractal values change with the evolution of cracks during the fracture process ... (Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fracture surfaces are the fracture process marks, taht it is characterized by energy release guieded by failure mode. The fracture toughness express this energy em stress and strain terms in pre-cracked samples. The strectch zone is the characteristic region forms by the transition of fatigue fracture and final fracture and it width demonstrate the relation with failure energy release.The quantitative fractography is a broadly tool uses in failure surfaces characterization that it can point to a material’s aspect or a fracture process. The image processing works like an investigation tool, guinding a lot of studies in this area. In order to evaluate the characterization effectivity and it respectivity studies, it used 300M steel that it was thermal treated by an aeronautical process known and it characterized by tensile test and energy dispersive spectroscopy (EDS). The tensile test of this material, made by ASTM E8, allowed the head treatment effectivity confirmation, beyond of mechanics porperties determination. The EDS confirmed the material composition, beyond of base the discussion about fracture mechanism presence. The fracture toughness test has also made, that it works to obtain the fracture surfeaces studies below self-similarity and self-affinity approaches. In front of all the exposed it was possible to conclude that the fractal dimension works like a study parameter of fracture process, allowinf the relation of their values with changes in thickness, which interferes directly in material’s behaviour in fracture toughness approach

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fracture surfaces express sequences of events of energy release with crack propagation in metal alloys, the evolution of topographic features can indicate the lines of load action, failures during the use or processing. The quantitative fractography is an important tool in the study of fracture surfaces, because it allows their interpretation and characterization. In order to evaluate the effectiveness of the characterization of fracture surfaces grounded on concepts such as selfsimilarity and self-affinity, it used the 15-5PH steel that was characterized by metallographic and tensile tests. The metallography allows the microstructural characterization of this steel and proved the presence of the martensite phase in the slats form and a fine-grained, both in the radial and in the axial direction of the dowel. The tensile test (ASTM E8) of this material allowed the determination of the mechanical properties, so based on the obtained results it was possible to affirm that the 15-5PH steel has high mechanical properties and a good stretch. Besides, the specimens also underwent testing of crack propagation, standardized by ASTM E647-00, thus it was obtained the fracture surfaces for characterization under monofractal and multifractal approaches. In front of all the exposed it was possible to conclude that in all measurements the correlation between the crack tip position and the fractal dimension was established in accordance with changes in the thickness and in the fracture micromechanisms presents. Furthermore, the multifractal approach was more sensitive to these variations allowing a more detailed characterization of the morphology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: This study compared fractal dimension (FD) values on mandibular trabecular bone in digital and digitized images at different spatial and contrast resolutions. Materials and Methods: 12 radiographs of dried human mandibles were obtained using custom-fabricated hybrid image receptors composed of a periapical radiographic film and a photostimulable phosphor plate (PSP). The film/ PSP sets were disassembled, and the PSPs produced images with 600 dots per inch (dpi) and 16 bits. These images were exported as tagged image file format (TIFF), 16 and 8 bits, and 600, 300 and 150 dpi. The films were processed and digitized 3 times on a flatbed scanner, producing TIFF images with 600, 300 and 150 dpi, and 8 bits. On each image, a circular region of interest was selected on the trabecular alveolar bone, away from root apices and FD was calculated by tile counting method. Two-way ANOVA and Tukey’s test were conducted to compare the mean values of FD, according to image type and spatial resolution (α = 5%). Results: Spatial resolution was directly and inversely proportional to FD mean values and standard deviation, respectively. Spatial resolution of 150 dpi yielded significant lower mean values of FD than the resolutions of 600 and 300 dpi ( P < 0.05). A nonsignificant variability was observed for the image types ( P > 0.05). The interaction between type of image and level of spatial resolution was not signi fi cant (P > 0.05). Conclusion: Under the tested, conditions, FD values of the mandibular trabecular bone assessed either by digital or digitized images did not change. Furthermore, these values were in fluenced by lower spatial resolution but not by contrast resolution.