205 resultados para Disinfection in endodontics


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives To evaluate the presence of fungi on contact electrodes and ultrasound transducers from physiotherapy clinics.Design Quantitative study conducted at the Laboratory of Microbiology and Immunology, Faculty of Health Sciences and Technology of Piaui - NOVAFAPI, Teresina, Brazil.Setting Sample collection was performed in 10 clinics ( 20 ultrasound transducers and 20 contact electrodes).Main outcome measures Swabs were soaked with saline solution, inoculated in culture and incubated for filamentous fungi and yeast growth.Results Fourteen taxons were identified: Acremomium hyalinulum (Sacc.), Aspergillus terreus, Candida albicans, Cladosporium cladosporioides, Cladosporium elatum, Cladosporium oxysporum, Cladosporium sphaerospermum, Cladosphialophora bantiana, Curvularia clavata, Curvularia senegalensis, Fusarium oxysporum, Penicillium decumbens, Scopulariopsis candida and Sporothrix schenckii. Aspergillus terreus, Cladosporium oxysporum, Sporothrix shenckii and Candida albicans were found most often on contact electrodes, and Penicillium decumbens and Cladosporium cladosporioides were found most often on ultrasound transducers.Conclusion Fungi were found on all of the contact electrodes and ultrasound transducers. Physiotherapy professionals need to improve the disinfection procedures for this equipment. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, water and eight sanitizing solutions (vinegar at 6, 25, and 50%; acetic acid at 2 and 4%; peracetic acid at 80 ppm, sodium hypochlorite at 200 ppm, and sodium dichloroisocyanurate at 200 ppm) were compared in terms of their effectiveness against the natural microbiota of lettuce. All of the samples were kept in contact with the sanitizing solutions for 15 min, and the effectiveness of a sanitizing agent was evaluated on the basis of the number of decimal reductions of the total aerobic mesophilic count, the mold and yeast count, the total coliform count, and the Escherichia coli count. The average initial levels of these organisms in the samples were 6.94 log(10) CFU/g for aerobic mesophilic microorganisms, 5.62 log(10) CFU/g for molds and yeasts, and 3.25 log(10) CFU/g for total coliforms. of 10 samples analyzed, only 4 contained E. coli, and the average initial level of this microorganism in these 4 samples was 1.64 log(10) CFU/g. Salmonella was not detected in any of the samples tested. The decimal reductions of the populations of aerobic mesophilic microorganisms, molds and yeasts, total coliforms, and E. coli were 0.78, 0.87, 0.82, and >0.14 log(10) CFU/g, respectively, in water; 2.89, >3.41, >2.21, and >0.26 log(10) CFU/g, respectively, in 50% vinegar; 2.42, >3.20, >1.99, and >0.26 log(10) CFU/g, respectively, in 25% vinegar; 1.83, 2.57, 1.58, and >0.26 log(10) CFU/g, respectively, in 6% vinegar; 3.91, >3.58, >2.25, and >0.26 log(10) CFU/g, respectively, in 4% acetic acid; 3.37, >3.53, >2.25, and >0.26 log(10) CFU/g, respectively, in 2% acetic acid; 1.85, 2,32, 1.44, and >0.20 log(10) CFU/g, respectively, in 80 ppm of peracetic acid; 2.63, 2.75, 1.91, and >0.26 log(10) CFU/g, respectively, in 200 ppm of sodium hypochlorite; and 3.23, >3.08, >1.95, and >0.26 log(10) CFU/g, respectively, in 200 ppm of sodium dichloroisocyanurate. Statistical analysis of the results showed that the effectiveness levels for all of the sanitizing agents tested were equivalent to or higher than that for sodium hypochlorite at 200 ppm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mineral trioxide aggregate (MTA) and Portland cement are being used in dentistry as root end-filling materials. However, biocompatibility data concerning genotoxicity and cytotoxicity are needed for complete risk assessment of these compounds. In the present study, genotoxic and cytotoxic effects of MTA and Portland cements were evaluated in vitro using the alkaline single cell gel (comet) assay and trypan blue exclusion test, respectively, on mouse lymphoma cells. The results demonstrated that the single cell gel (comet) assay failed to detect DNA damage after a treatment of cells by MTA and Portland cements for concentrations up to 1000 mu g/ml. Similarly, results showed that none of the compounds tested were cytotoxic. Taken together, these results seem to indicate that MTA and Portland cements are not genotoxins and do not induce cellular death.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. In the current study, the potential DNA damage associated with exposure to a number of antimicrobial endodontic compounds was assessed by the single cell gel (comet) assay in vitro.Study design. Chinese hamster ovary (CHO) cells were exposed to formocresol, paramonochlorophenol, calcium hydroxide, or chlorhexidine at final concentration ranging from 0.01% to 1%.Results. Formocresol, paramonochlorophenol, and calcium hydroxide, as well as chlorhexidine in all concentrations tested did not contribute to the DNA damage.Conclusion. These findings are clinically relevant since they represent an important contribution to the correct evaluation of the potential health risk associated with exposure to dental agents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The failure of facial prostheses is caused by limitations in their flexibility and durability. Therefore, we evaluated the effects of disinfection and aging on Shore A hardness and deterioration of a facial silicone with different pigmentations. Twenty samples with addition of each pigment (ceramic (C), make-up (M)) and without pigment (L) were made. For each pigment type and no pigment, 10 samples were subjected to two types of disinfectant solution (soap (S) and Efferdent (E)), totaling sixty samples. The specimens were disinfected three times per week for 60 days, and subjected to accelerated aging for 1008 h. The hardness of the facial silicone was measured with a durometer, and its deterioration was evaluated by obtaining the weight difference over time. Both the hardness and weight of the samples were measured at baseline, after chemical disinfection, and periodically during accelerated aging (252, 504, and 1008 h). Deterioration was calculated during the periods between baseline and chemical disinfection, and between baseline and each aging period. The results were analyzed using three-way repeated measures ANOVA and the Tukey's HSD Post-hoc test (alpha = 0.05). Specifically, samples containing pigment exhibited significantly higher hardness and deterioration values than those lacking pigment (P < 0.05). In addition, period of time (disinfection and accelerated aging) statistically increased the hardness and deterioration values of the silicone (P < 0.05). It can be concluded that both pigment and time statistically affected the hardness and deterioration of the silicone elastomer. (c) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The failure of facial prostheses is caused by limitations in the properties of existing materials, especially flexibility and durability. Therefore, this study evaluated the Shore A hardness of silicone used for fabrication of facial prostheses, Silastic MDX4-4210, according to the influence of storage period, daily disinfection, and 2 types of pigmentation. Thirty specimens were fabricated and divided in 3 groups: colorless, pigmented with makeup, and pigmented with iron oxide. Analysis of results was assessed on a Shore A hardness meter immediately, 6 months, and 1 year after fabrication of specimens, following the guidelines of the American Society for Testing and Materials. The hardness values were statistically analyzed by the Tukey test. The silicone exhibited an increase in hardness with time. However, the hardness was stable from 6 months to 1 year. It was concluded that the silicone is within the values of Shore A hardness reported in the literature, regardless of the storage period, pigmentation, and chemical disinfection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the color stability of a maxillofacial elastomer with the addition of a nanoparticle pigment and/or an opacifier submitted to chemical disinfection and artificial aging. Specimens were divided into four groups (n = 30): group I: silicone without pigment or opacifier, group II: ceramic powder pigment, group III: Barium sulfate (BaSO(4)) opacifier, and group IV: ceramic powder and BaSO(4) opacifier. Specimens of each group (n = 10) were disinfected with effervescent tablets, neutral soap, or 4% chlorhexidine gluconate. Disinfection was done three times a week during two months. Afterward, specimens were submitted to different periods of artificial aging. Color evaluation was initially done, after 60 days (disinfection period) and after 252, 504, and 1008 h of artificial aging with aid of a reflection spectrophotometer. Data were analyzed by three-way ANOVA and Tukey test (alpha = 0.05). The isolated factor disinfection did not statistically influence the values of color stability among groups. The association between pigment and BaSO(4) opacifier (GIV) was more stable in relationship to color change (Delta E). All values of Delta E obtained, independent of the disinfectant and the period of artificial aging, were considered acceptable in agreement with the norms presented in literature. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3625401]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to investigate the influence of the type of vehicle (distilled water or propyleneglycol) on the response of apical tissues of dogs' teeth after root canal filling with mineral trioxide aggregate (MTA) at two different limits. Forty roots of incisors and premolars of two adult dogs were used. After pulpectomy, the root canals were prepared biomechanically, and the roots had the apical cemental barrier penetrated with a #15 K-file and widened to a #25 K-file. The root canals were assigned to four groups according to the vehicle used for MTA (ProRoot-MTA; Tulsa Dental, Tulsa, OK) preparation and the limit of root canal filling: group 1, filling with MTA/distilled water to the limit of the cemental canal; group 2, overfilling with MTA/distilled water, group 3, filling with MTA/propyleneglycol to the limit of the cemental canal; and group 4, overfilling with MTAlpropyleneglycol. The animals were killed by anesthetic overdose 90 days after endodontic treatment and the anatomic pieces were prepared for histomorphological analysis. The sections were stained with hematoxylin and eosin and Brown and Brenn techniques. The results showed that MTA pastes prepared with either distilled water or propyleneglycol as vehicles had similar biological behavior (p > 0.05); root fillings placed at the cemental canal limit showed better results than the overfillings (p = 0.01), and MTA/propyleneglycol paste was more easily placed into the root canals than MTA/distilled water paste.