97 resultados para Derivative instruments
Resumo:
In some practical problems, for instance in the control systems for the suppression of vibration in mechanical systems, the state-derivative signals are easier to obtain than the state signals. New necessary and sufficient linear matrix inequalities (LMI) conditions for the design of state-derivative feedback for multi-input (MI) linear systems are proposed. For multi-input/multi-output (MIMO) linear time-invariant or time-varying plants, with or without uncertainties in their parameters, the proposed methods can include in the LMI-based control designs the specifications of the decay rate, bounds on the output peak, and bounds on the state-derivative feedback matrix K. These design procedures allow new specifications and also, they consider a broader class of plants than the related results available in the literature. The LMIs, when feasible, can be efficiently solved using convex programming techniques. Practical applications illustrate the efficiency of the proposed methods.
Resumo:
The structure of 5,7,9,10-tetramethoxy-3-methyl-1 H-naphtho[2,3-c]pyran-1-one, C18H18O6, a derivative of a natural isocoumarin isolated from Paepalanthus bromelioides, was determined by X-ray analysis, which unequivocally confirmed the previously assigned structure. Small deviations from the standard angles, resulting from steric hindrance between the methoxyl and carbonyl groups, were observed.
Resumo:
Introduction: The aim of this study was to assess the occurrence of apical root transportation after the use of Pro Taper Universal rotary files sizes 3 (F3) and 4 (F4). Methods: Instruments were worked to the apex of the original canal, always by the same operator. Digital subtraction radiography images were produced in buccolingual and mesiodistal projections. A total of 25 radiographs were taken from root canals of human maxillary first molars with curvatures varying from 23-31 degrees. Quantitative data were analyzed by intraclass correlation coefficient and Wilcoxon nonparametric test (P = .05). Results: Buccolingual images revealed a significantly higher degree of apical transportation associated with F4 instruments when compared with F3 instruments in relation to the original canal (Wilcoxon test, P = .007). No significant difference was observed in mesiodistal images (P = .492). Conclusions: F3 instruments should be used with care in curved canals, and F4 instruments should be avoided in apical third preparation of curved canals. (J Endod 2010;36:1052-1055)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
4-Methylpyrimidine-2-thione reacts with methylmercury hydroxide to give the thiolate derivative HgMe(SC4H2N2Me-2), the X-ray structure of which reveals pairs of molecules with a mercury-mercury distance of 3.10 Å.
Resumo:
We present a higher derivative gauge theory in (2 + 1) dimensions which can have its parameters suitably tuned in order to become a consistent quantum field theory, in the sense that both tachyons and ghosts are absent from the particle spectrum of the theory.
Resumo:
It is shown that massive fermions have their helicity flipped on account of their interaction with an electromagnetic field described by Podolsky's generalized electrodynamics. Massless fermions, in turn, seem to be unaffected by the electromagnetic field as far as their helicity is concerned. © Springer-Verlag 1997.
Resumo:
The electrochemical behavior of aniline protected by a nitrobenzene sulphonyl group in aqueous solution at a mercury electrode is reported. At pH < 10 the compound was reduced in a single well-defined step. Reduction of the nitro group involving a preceding protonation step was postulated. Two reduction steps are present at higher pH (pH > 11). Controlled potential electrolysis confirms that the reduction of the nitro group in a four-electron step to N-phenyl-4-hydroxylamine sulphonamide is always the preponderant process. ©1997 Soc. Bras. Química.
Resumo:
Fifty-four extracted human mandibular molars were embedded and sectioned at two levels. The reassembled mesial root canals were prepared with stainless-steel hand K-files (Flexofiles) and either Nitiflex or Mity nickel-titanium hand K-files using a push-pull anticurvature filing technique. Each of the three experimental groups contained 36 mesial canals randomly distributed. Superimposed pre- and postinstrumentation cross-sectional root images were magnified using a stereomicroscope and transferred to a computer for measurement and statistical analysis. The direction and extent of canal center movement were evaluated. At the apical level, the groups produced no significant difference of direction of canal center movement. In cervical sections, all groups tended to move in a distolingual direction. The three groups, however, produced no significant difference in the cervical sections in the extent of canal center movement. In apical sections, Nitiflex produced the least canal center movement. Copyright © 1999 by The American Association of Endodontists.