82 resultados para Constant Loading Rate


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Water and soil pollution caused by the waste from the swine production causes severe environmental impacts in producing areas. An efficient alternative to reduce these impacts can be the use of high-rate anaerobic reactors. In this work, it was evaluated the effect of the swine wastewater with total suspended solids concentrations around 6.000 mg.L-1 in the anaerobic baffled reactor with three compartments. The volume of the first compartment was 210 L and of the second and third ones of 160 L. The anaerobic baffled reactor was submitted at hydraulic detention times of 56, 28 and 18 hours and to organic load rates of 5.0 to 10.1 g total COD (L.d)(-1). The highest total COD removals, of 42 to 68%, and volumetric methane productions, of 0.261 to 0.454 L CH4 (L reactor d)(-1), occurred in the second compartment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Experimental programs in constant and variable amplitude loading were performed to obtain a x N curves and to study retardation in fatigue crack growth due to overloads. The main aim of this research program was to analyse the effect of overload ratio and number of overload peaks. The effect of underloads, before and after the overload blocks was also studied. The generalised equation of Paris-Erdogan type was used for modelling of obtained data on crack propagation under constant amplitude load.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective - To evaluate the effects of increasing doses of remifentanil hydrochloride administered via constant rate infusion (CRI) on the minimum alveolar concentration (MAC) of isoflurane in cats. Animals - 6 healthy adult cats. Procedures - For each cat, 2 experiments were performed (2-week interval). On each study day, anesthesia was induced and maintained with isoflurane; a catheter was placed in a cephalic vein for the administration of lactated Ringer's solution or remifentanil CRIs, and a catheter was placed in the jugular vein for collection of blood samples for blood gas analyses. On the first study day, individual basal MAC (MAC Basal) was determined for each cat. On the second study day, 3 remifentanil CRIs (0.25, 0.5, and 1.0 μg/kg/min) were administered (in ascending order); for each infusion, at least 30 minutes elapsed before determination of MAC (designated as MAC R0.25, MAC R0.5, and MAC R1.0, respectively). A 15-minute washout period was allowed between CRIs. A control MAC (MAC Control) was determined after the last remifentanil infusion. Results - Mean ± SD MAC Basal and MAC Control values at sea level did not differ significantly (1.66 ± 0.08% and 1.52 ± 0.21%, respectively). The MAC values determined for each remifentanil CRI did not differ significantly. However, MAC R0.25, MAC R0.5, and MAC R1.0, were significantly decreased, compared with MAC Basal, by 23.4 ± 79%, 29.8 ± 8.3%, and 26.0 ± 9.4%, respectively. Conclusions and Clinical Relevance - The 3 doses of remifentanil administered via CRI resulted in a similar degree of isoflurane MAC reduction in adult cats, indicating that a ceiling effect was achieved following administration of the lowest dose.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Constant rate infusion (CRI) shows several advantages in balanced anesthesia, such as reduction of requirement for inhaled anesthetics and control of pain. The most commonly used drugs in these protocols are local anesthetics, dissociative, and opioids, which may be administered alone or in combinations. We evaluated the records of 200 dogs that underwent various surgical procedures with anesthetic or analgesic CRI in the perioperative period during 2011 and 2012 at the Veterinary Hospital of Franca University (Unifran), and identified possible complications during the transoperative period. Records evaluated included clinical state, laboratory tests, drugs used in premedication and induction, and CRI protocol. Acepromazine and morphine were the main drugs used in premedication. Propofol was used to induce anesthesia alone or in combination with other agents. We evaluated records of the 25 different CRI protocols. Fentanyl was the main drug employed in CRI, either alone or in combination. There were 128 episodes of anesthetic complications during CRI;the most common were hypotension, hypertension, and tachycardia, which occurred in 43 (32%), 35 (26.3%), and 19 (14.2%) dogs, respectively. Cardiac arrhythmia was reported in only 4 dogs. Signs of respiratory depression were present in dogs treated with 6 different CRI protocols. The consumption of isoflurane (vol %) reduced between 15.7% and 21.05% after 30minutes of the CRI in the fentanyl and fentanyl-lidocaine-ketamine CRI groups (p<0.05). In conclusion, CRI is a valid component of balanced anesthesia in dogs, safe, and has a low incidence of adverse effects. However, future studies are warranted to describe the results of the clinical use of CRI to better characterize and refine this technique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The characterization of the hyperbolic power-time (P-tlim) relationship using a two-parameter model implies that exercise tolerance above the asymptote (Critical Power; CP), i.e. within the severe intensity domain, is determined by the curvature (W') of the relationship. The purposes of this study were (1) to test whether the amount of work above CP (W>CP) remains constant for varied work rate experiments of high volatility change and (2) to ascertain whether W' determines exercise tolerance within the severe intensity domain. Following estimation of CP (208 ± 19 W) and W' (21.4 ± 4.2 kJ), 14 male participants (age: 26 ± 3; peak [Formula: see text]: 3708 ± 389 ml.min-1) performed two experimental trials where the work rate was initially set to exhaust 70% of W' in 3 ('THREE') or 10 minutes ('TEN') before being subsequently dropped to CP plus 10 W. W>CP for TEN (104 ± 22% W') and W' were not significantly different (P>0.05) but lower than W>CP for THREE (119 ± 17% W', P<0.05). For both THREE (r = 0.71, P<0.01) and TEN (r = 0.64, P<0.01), a significant bivariate correlation was found between W' and tlim. W>CP and tlim can be greater than predicted by the P-tlim relationship when a decrement in the work rate of high-volatility is applied. Exercise tolerance can be enhanced through a change in work rate within the severe intensity domain. W>CP is not constant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fertility life tables were developed for both Trichogramma pretiosum and Trichogramma acacioi reared on Sitotroga cerealella eggs as an alternative host at five different temperatures. The egg parasitoids were first collected from Nipteria panacea eggs, a lepidopterous pest of avocado. Egg parasitoid females were individualized in small glass vials along with 40 eggs of the host during 24 h for parasitization. For evaluation of the parasitism capacity, a similar procedure was adopted, but cardboards with eggs were replaced every day. The net reproductive rate (Ro), intrinsic rate of increase (rm), finite rate of increase (lambda), and mean generation time (T) were estimated. Temperature affected all parameters for both Trichogramma species. The highest fecundity for both species was observed at 25degreesC. Extreme temperatures such as 15degreesC or 35degreesC negatively affect the development rate of both species.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work reports dielectric measurements performed on Pb(Zr0.53Ti0.47)O3 (PZT) thin films prepared by a polymeric precursor method. The -E curves obtained for the PZT film measured at 100 kHz, under a small ac 0.2 kV/cm signal-test and a dc scan featured a typical butterfly curve. However, the -E curves obtained for PZT film under a dc scan, with a scan rate of 0.003 V/s, shows a pronounced asymmetry. The absence of a symmetric secondary peak in -E curves could be an indication of essentially 180 domain switching.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)