75 resultados para Computer aided design


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives-The purpose of this study was to predict perinatal outcomes using fetal total lung volumes assessed by 3-dimensional ultrasonography (3DUS) in primary pleural effusion.Methods-Between July 2005 and July 2010, total lung volumes were prospectively estimated in fetuses with primary pleural effusion by 3DUS using virtual organ computer-aided analysis software. The first and last US examinations were considered in the analysis. The observed/expected total lung volumes were calculated. Main outcomes were perinatal death (up to 28 days of life) and respiratory morbidity (orotracheal intubation with mechanical respiratory support >48 hours).Results-Twelve of 19 fetuses (63.2%) survived. Among the survivors, 7 (58.3%) had severe respiratory morbidity. The observed/expected total lung volume at the last US examination before birth was significantly associated with perinatal death (P < .01) and respiratory morbidity (P < .01) as well as fetal hydrops (P < .01) and bilateral effusion (P = .01).Conclusions-Fetal total lung volumes may be useful for the prediction of perinatal outcomes in primary pleural effusion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Making diagnoses in oral pathology are often difficult and confusing in dental practice, especially for the lessexperienced dental student. One of the most promising areas in bioinformatics is computer-aided diagnosis, where a computer system is capable of imitating human reasoning ability and provides diagnoses with an accuracy approaching that of expert professionals. This type of system could be an alternative tool for assisting dental students to overcome the difficulties of the oral pathology learning process. This could allow students to define variables and information, important to improving the decision-making performance. However, no current open data management system has been integrated with an artificial intelligence system in a user-friendly environment. Such a system could also be used as an education tool to help students perform diagnoses. The aim of the present study was to develop and test an open case-based decisionsupport system.Methods: An open decision-support system based on Bayes' theorem connected to a relational database was developed using the C++ programming language. The software was tested in the computerisation of a surgical pathology service and in simulating the diagnosis of 43 known cases of oral bone disease. The simulation was performed after the system was initially filled with data from 401 cases of oral bone disease.Results: the system allowed the authors to construct and to manage a pathology database, and to simulate diagnoses using the variables from the database.Conclusion: Combining a relational database and an open decision-support system in the same user-friendly environment proved effective in simulating diagnoses based on information from an updated database.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A green ceramic tape micro-heat exchanger was developed using Low Temperature Co-fired Ceramics technology (LTCC). The device was designed by using Computational Aided Design software and simulations were made using a Computational Fluid Dynamics package (COMSOL Multiphysics) to evaluate the homogeneity of fluid distribution in the microchannels. Four geometries were proposed and simulated in two and three dimensions to show that geometric details directly affect the distribution of velocity in the micro-heat exchanger channels. The simulation results were quite useful for the design of the microfluidic device. The micro-heat exchanger was then constructed using the LTCC technology and is composed of five thermal exchange plates in cross-flow arrangement and two connecting plates, with all plates stacked to form a device with external dimensions of 26 x 26 x 6 mm(3).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Usability evaluation (UE) methods may have several purposes: identify and diagnose usability problems; evaluate the implementation, comparing the one under evaluation with other systems, and also perform acceptance test. These methods are usually expensive, time-consuming and complex. In this context, the ErgoCoIn 1.0 has being used as an accessible system that can be used by several people all over the world, even if they are not usability experts or evaluators. This paper aims to present a new version of this environment considering that its basic objective is to propose a higher quality for the questions. Additionally, a new presentation questionnaire window small enough to be used both in web browsers and mobile devices is proposed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Teaching a course of special electric loads in a continuing education program to power engineers is a difficult task because they are not familiarized with switching topology circuits. Normally, in a typical program, many hours are dedicated to explain the thyristors switching sequence and to draw the converter currents and terminal voltages waveforms for different operative conditions. This work presents teaching support software in order to optimize the time spent in this task and, mainly to benefit the assimilation of the proposed subjects, studying the static converter under different non-ideal operative conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A linearly-tunable ULV transconductor featuring excellent stability of the processed signal common-mode voltage upon tuning, critical for very-low voltage applications, is presented. Its employment to the synthesis of CMOS gm-C high-frequency and voiceband filters is discussed. SPICE data describe the filter characteristics. For a 1.3 V-supply, their nominal passband frequencies are 1.0 MHz and 3.78 KHz, respectively, with tuning rates of 12.52 KHz/mV and 0.16 KHz/m V, input-referred noise spectral density of 1.3 μV/Hz1/2 and 5.0μV/Hz1/2 and standby consumption of 0.87 mW and 11.8 μW. Large-signal distortion given by THD = 1% corresponds to a differential output-swing of 360 mVpp and 480 mVpp, respectively. Common-mode voltage deviation is less than 4 mV over tuning interval.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a high speed current mode CMOS comparator. The comparator was optimized for allows wide range input current 1mA, ±0.5uA resolution and has fast response. This circuit was implemented with 0.8μm CMOS n-well process with area of 120μm × 105μm and operates with 3.3V(±1.65V).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The communication between user and software is a basic stage in any Interaction System project. In interactive systems, this communication is established by the means of a graphical interface, whose objective is to supply a visual representation of the main entities and functions present in the Virtual Environment. New ways of interacting in computational systems have been minimizing the gap in the relationship between man and computer, and therefore enhancing its usability. The objective of this paper, therefore, is to present a proposal for a non-conventional user interface library called ARISupport, which supplies ARToolKit applications developers with an opportunity to create simple GUI interfaces, and provides some of the functionality used in Augmented Reality systems. © Springer-Verlag Berlin Heidelberg 2005.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main purpose of this work is the development of computational tools in order to assist the on-line automatic detection of burn in the surface grinding process. Most of the parameters currently employed in the burning recognition (DPO, FKS, DPKS, DIFP, among others) do not incorporate routines for automatic selection of the grinding passes, therefore, requiring the user's interference for the choice of the active region. Several methods were employed in the passes extraction; however, those with the best results are presented in this article. Tests carried out in a surface-grinding machine have shown the success of the algorithms developed for pass extraction. Copyright © 2007 by ABCM.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes a software tool, called LEVSOFT, suitable for the electric field simulations of corona electrodes by the Finite Element Method (FEM). Special attention was paid to the user friendly construction of geometries with corners and sharp points, and to the fast generation of highly refined triangular meshes and field maps. The execution of self-adaptive meshes was also implemented. These customized features make the code attractive for the simulation of needle-type corona electrodes. Some case examples involving needle type electrodes are presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 24-year-old male patient was the victim of a firearm wound that penetrated the thorax. He arrived at another hospital hemodynamically unstable and was submitted to exploratory surgery by means of bithoracotomy. A lesion of the left branch of the pulmonary artery was detected and successfully repaired. He was submitted for computer-aided tomography on the fifth postoperative day, and a lesion of the mid-thoracic aorta was detected, which formed a saccular image. Considering that the patient had already been submitted to a bithoracotomy and that a direct approach to repair would involve another thoracotomy within a short period of time, endovascular treatment was chosen in our hospital. The procedure was performed under fluoroscopy. A second computer-aided tomography indicated adequate treatment of the lesion, with no indication of an endoleak. He has undergone ambulatory follow-up for 36 months without any problem related to the procedure. While endovascular treatment of the aorta has developed enormously, multicenter studies are needed to better define the long-term results of this approach. © 2008 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A green ceramic tape micro heat exchanger was developed using LTCC technology. The device was designed by using a CAD software and 2D and 3D simulations using a CFD package (COMSOL Multiphysics) to evaluate the fluid behavior in the microchannels. The micro heat exchanger is composed of five thermal exchange plates in cross flow arrangement and two connecting plates; heat exchanger dimensions are 26 × 26 × 6 mm3. Preliminary tests were carried out to characterize the device both in atmospheric pressure and in vacuum. The same techniques used in vacuum technology were applied to check the rotameters and to prevent device leakages. Thermal performance of the micro heat exchanger was experimentally tested. © 2009 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The advance in the graphic computer's techniques and computer's capacity of processing made possible applications like the human anatomic structures modeling, in order to investigate diseases, surgical planning or even provide images for training of Computer Aided Diagnosis (CAD). On this context, this work exhibits an anatomical model of cardiac structures represented in a tridimensional environment. The model was represented with geometrical elements and has anatomical details, as the different tunics that compose the cardiac wall and measures that preserves the characteristics found on real structures. The validation of the anatomical model was made through quantitative comparations with real structures measures, available on specialized literature. The results obtained, evaluated by two specialists, are compatible with real anatomies, respecting the anatomical particularities. This degree of representation will allow the verification of the influence of radiological parameters, morphometric peculiarities and stage of the cardiac diseases on the quality of the images, as well as on the performance of the CAD. © 2010 IEEE.