53 resultados para Braquetes invisíveis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The orthodontic treatment using lingual brackets has been desired by adult patients for esthetic factors. In this paper it is described the clinical steps of an orthodontic treatment using Incognito™ system, individualized lingual brackets and archwires designed by CAD/CAM technology. Methods: The presented case describes the treatment of a patient with mesofacial growth pattern,Class I malocclusion, with mandibular crowding and diastema between the upper central incisors, treated using 100% individualized lingual brackets. Results: After treatment, the molar relation of Class I was kept, the spaces between upper central incisors were closed and mandibular crowding corrected. Conclusion: This case report demonstrated the efficiency of the new method for lingual orthodontic treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to assess the time spent for direct (DBB - direct bracket bonding) and indirect (IBB - indirect bracket bonding) bracket bonding techniques. The time length of laboratorial (IBB) and clinical steps (DBB and IBB) as well as the prevalence of loose bracket after a 24-week follow-up were evaluated. METHODS: Seventeen patients (7 men and 10 women) with a mean age of 21 years, requiring orthodontic treatment were selected for this study. A total of 304 brackets were used (151 DBB and 153 IBB). The same bracket type and bonding material were used in both groups. Data were submitted to statistical analysis by Wilcoxon non-parametric test at 5% level of significance. RESULTS: Considering the total time length, the IBB technique was more time-consuming than the DBB (p < 0.001). However, considering only the clinical phase, the IBB took less time than the DBB (p < 0.001). There was no significant difference (p = 0.910) for the time spent during laboratorial positioning of the brackets and clinical session for IBB in comparison to the clinical procedure for DBB. Additionally, no difference was found as for the prevalence of loose bracket between both groups. CONCLUSION: the IBB can be suggested as a valid clinical procedure since the clinical session was faster and the total time spent for laboratorial positioning of the brackets and clinical procedure was similar to that of DBB. In addition, both approaches resulted in similar frequency of loose bracket.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to assess by means of scanning electron microscopy (SEM) the remaining adhesive interface after debonding orthodontic attachments bonded to bovine teeth with the use of hydrophilic and hydrophobic primers under different dental substrate moisture conditions. MATERIAL AND METHODS: Twenty mandibular incisors were divided into four groups (n=5). In Group I, bracket bonding was performed with Transbond MIP hydrophilic primer and Transbond XT adhesive paste applied to moist substrate, and in Group II a bonding system comprising Transbond XT hydrophobic primer and adhesive paste was applied to moist substrate. Brackets were bonded to the specimens in Groups III and IV using the same adhesive systems, but on dry dental enamel. The images were qualitatively assessed by SEM. RESULTS: The absence of moisture in etched enamel enabled better interaction between bonding materials and the adamantine structure. The hydrophobic primer achieved the worst micromechanical interlocking results when applied to a moist dental structure, whereas the hydrophilic system proved versatile, yielding acceptable results in moist conditions and excellent interaction in the absence of contamination. CONCLUSION: The authors assert that the best condition for the application of primers to dental enamel occurs in the absence of moisture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate, in vitro, the chromatic behavior of esthetic brackets stored in potentially staining solutions. The sample were divided into four groups according to the commercial brand and stored in four different solutions (distilled water, cola soda, coffee and mouthrinse) at 37°C for 14 days. Possible color changes measured according to the CIE L*a*b* color system with a spectrophotometer at five intervals of time after storage. The statistical analysis was carried out using ANOVA to 1%, Tukey's tests and decomposition of interactions with a significance level of 5%.The color changes were dependent on the solution, storage time and the brand of brackets. The largest color changes were observed in the G3, followed by G2, G1/G4. The esthetic brackets do not present satisfactory and stable chromatic behavior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: a proposta desse estudo foi avaliar, por meio de microscopia eletrônica de varredura (MEV), a interface adesiva após a descolagem de acessórios ortodônticos, fixados em dentes bovinos com emprego de adesivo hidrofílico e hidrofóbico, em condições distintas de umidade do substrato dentário. Métodos: foram utilizados 20 incisivos inferiores, divididos em quatro grupos (n = 5): Grupo I , empregou-se o sistema de colagem contendo o primer hidrofílico Transbond MIP e a pasta adesiva Transbond XT, aplicados em substrato úmido; Grupo II, empregou-se o sistema de colagem primer hidrofóbico Transbond XT e pasta adesiva em substrato úmido; Grupos III e IV, os braquetes foram colados com os mesmos sistemas de união dos Grupos I e II, porém com esmalte dentário seco. Removidos os acessórios, avaliou-se em MEV, em diferentes magnificações, a interface adesiva e a interação dos sistemas adesivos com o esmalte dentário. As imagens foram avaliadas qualitativamente, observando-se o embricamento mecânico para o adesivo hidrófilo em quaisquer condições de substrato. Resultados: a falta de umidade no esmalte condicionado permitiu uma melhor interação entre os materiais de ligação e a estrutura adamantina. O adesivo hidrofóbico apresentou o pior resultado de interação micromecânica quando aplicado a uma estrutura dentária úmida; já o sistema hidrofílico mostrou-se versátil, obtendo resultados aceitáveis em condições de umidade e excelente interação na ausência de contaminação. Conclusão: os autores afirmam que a melhor condição do esmalte dentário para a aplicação de primers é com a ausência de umidade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Resenha do livro Histórias invisíveis de Mõnica Rebecca Ferrari Nunes e Marco Antonio Bin, lançado em 2011, durante o songresso da Socicom.