Conventional radiography, using industrial radiographic films, has its days numbered. Digital radiography, recently, has taken its place in various segments of products and services, such as medicine, aerospace, security, automotive, etc. As well as the technological trend, the digital technique has brought proven benefits in terms of productivity, sensitivity, the environment, tools for image treatment, cost reductions, etc. If the weld to be inspected is on a serried product, such as, for example, a pipe, the best option for the use of digital radiography is the plane detector, since its use can reduce the length of the inspection cycle due to its high degree of automation. This work tested welded joints produced with the submerged arc process, which were specially prepared in such a way that it shows small artificial cracks, which served as the basis forcomparing the sensitivity levels of the techniques involved. After carrying out the various experiments, the digital meth odshowed the highest sensitivity for the image quality indicator (IQI) of the wire and also in terms of detecting small discontinuities, indicating that the use of digital radiography using the plane detector had advantages over the conventional technique (Moreira et al. Digital radiography, the use of plane detectors for the inspection of welds in oil pipes and gas pipes.9th COTEQ and XXV National Testing Congress for Non Destructive Testing and Inspection; Salvador, Bahia, Brazil and Bavendiek et al. New digital radiography procedure exceeds film sensitivity considerably in aerospace applications. ECNDT; 2006; Berlin). The works were carried out on the basis of the specifications for oil and gas pipelines, API 5L 2004 edition (American Petroleum Institute. API 5L: specification for line pipe. 4th ed. p. 155; 2004) and ISO 3183 2007 edition (International Organization for Standardization, ISO 3183. Petroleum and gas industries - steel pipes for pi pelines transportation systems. p. 143; 2007). © 2010 Taylor & Francis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The daily-to-day of medical practice is marked by a constant search for an accurate diagnosis and therapeutic assessment. For this purpose the doctor serves up a wide variety of imaging techniques, however, the methods using ionizing radiation still the most widely used because it is considered cheaper and above all very efficient when used with control and quality. The optimization of the risk-benefit ratio is considered a major breakthrough in relation to conventional radiology, though this is not the reality of computing and digital radiology, where Brazil has not established standards and protocols for this purpose. This work aims to optimize computational chest radiographs (anterior-posterior projection-AP). To achieve this objective were used a homogeneous phantoms that simulate the characteristics of absorption and scattering of radiation close to the chest of a patient standard. Another factor studied was the subjective evaluation of image quality, carried out by visual grading assessment (VGA) by specialists in radiology, using an anthropomorphic phantom to identify the best image for a particular pathology (fracture or pneumonia). Quantifying the corresponding images indicated by the radiologist was performed from the quantification of physical parameters (Detective Quantum Efficiency - DQE, Modulation Transfer Function - MTF and Noise Power Spectrum - NPS) using the software MatLab®. © 2013 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper was to report the diagnosis and evaluation of periradicular bone repair by using computed tomography and digital subtraction radiography in an endodontic surgery case treated with mineral trioxide aggregate (MTA). The patient had local swelling and fistula 7years after trauma in the upper jaw. Periapical lesion on tooth #12 and root resorption of tooth #11 were detected radiographically. Endodontic therapy and placement of intracanal medication were carried out. After 3months, with no improvement in the clinical signs and symptoms, computed tomography was performed, showing extensive apical bone resorption on tooth #12 and dental resorption promoting communication of the root canal with the periodontium of tooth #11. The patient was referred to endodontic surgery. After surgery and postoperative periods of 15, 30, 60, 90, and 120days, standardized radiographs were taken, digitized, and subjected to digital subtraction of the images using Adobe Photoshop CS software. Four years later, a cone-beam computed tomography was performed, showing bone repair and absence of root resorption at tooth #11. In this clinical case, digital subtraction radiography was effective for early detection of new bone formation and evolution of repair. © 2011 John Wiley & Sons A/S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The imaging is essential to aid the diagnosis of horses that have performance decrease associated with any pain or clinical signs related to the vertebral column. Radiography is the first imaging examination performed in these cases, particularly for disorders affecting the cervical region. However, this technique has limitations when the study of subtle changes due to the overlapping of adjacent structures. Computed tomography is a new diagnostic method in Brazil for the study of bone disorders in horses, but it is of great diagnostic value associate with the radiographic examination in order to provide an accurate assessment of the study area, owing to superiority in image quality when compared to conventional radiography. The aim of this study is increase and update knowledge of diagnostic imaging available to investigate cervical disorders in horses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Legg-Calvé-Perthes disease is a non-inflammatory aseptic necrosis of the head of the femur that is found in both young animals and humans before the gap in the femur head closes. In the fields of both human and veterinary medicine the cause of this condition is not known for certain. Various factors have been put forward in the literature as being responsible for the incidence of this condition such as: abnormalities in coagulation, changes in blood flow in the arteries, a septic obstruction in the draining of the epiphysis or the upper parts of the femur, trauma, growth cycle, hyperactivity in a child, genetic influences and dietary factors. Case histories in dogs show that the first stages of the condition progress slowly but that limping or putting weight on the limb worsens at 6 to 8 weeks. Some owners talk about a sharp onset in clinical lameness. Other clinical symptoms may include irritability, loss of appetite and knawing at the hair surrounding the affected hip. In the course of physical examination manipulating the hip joint will cause pain to the animal. The advanced stages of the disease may result in restricted amplitude of movement, muscular atrophy and fracturing. In humans the clinical signs are similar, although progression of the disease is slower so that it can be diagnosed at an earlier stage. In veterinary medicine the diagnosis is, in the main, based on case history, clinical symptoms, physical examination and certain related procedures such as radiography. The various diagnoses include physical trauma and dislocation of the medial patella. In human medicine many people have been correctly diagnosed. Whatsmore, there is a range of related procedures that are virtually not available to veterinary medicine such as magnetic nuclear resonance, that show up necroses with great clarity before radiography and cintilography do, and is considered... (Complete abstract click electronic access below)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption) that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm). The apparent tooth length (APTL) was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0), whereas the actual tooth length (ACTL) was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to optimize a radiographic technique for hand examinations using a computed radiography (CR) system and demonstrate the potential for dose reductions compared with clinically established technique. An exposure index was generated from the optimized technique to guide operators when imaging hands. Homogeneous and anthropomorphic phantoms that simulated a patient's hand were imaged using a CR system at various tube voltages and current settings (40-55 kVp, 1.25-2.8 mAs), including those used in clinical routines (50 kVp, 2.0 mAs) to obtain an optimized chart. The homogeneous phantom was used to assess objective parameters that are associated with image quality, including the signal difference-to-noise ratio (SdNR), which is used to define a figure of merit (FOM) in the optimization process. The anthropomorphic phantom was used to subjectively evaluate image quality using Visual Grading Analysis (VGA) that was performed by three experienced radiologists. The technique that had the best VGA score and highest FOM was considered the gold standard (GS) in the present study. Image quality, dose and the exposure index that are currently used in the clinical routine for hand examinations in our institution were compared with the GS technique. The effective dose reduction was 67.0%. Good image quality was obtained for both techniques, although the exposure indices were 1.60 and 2.39 for the GS and clinical routine, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nossa pesquisa consiste no estudo esquemático macroscópico na placenta de gatos e a sua caracterização como tipo, placenta zonária, que 62,5% dos casos apresenta uma fissura na área distal do funículo umbilical. Esse é formado por uma área justa fetal, área justa placentária e área média, encontrando achados histológicos de 2 artérias, uma veia, 2 pedículos vitelínicos e 2 pedículos alantoidianos. Na fissura, encontramos um epitélio alantoidiano cobrindo esta área em 10% dos casos e, em 90% dos achados foram encontrados um trofoblasto diminuído comparado com outras áreas placentárias fora da fissura. Portanto, a placenta felina, com sua relação materno fetal mostra uma placenta zonária incompleta, diferente do ocorrido nos outros carnívoros.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A doença degenerativa mixomatosa da válvula mitral (DDMVM) é uma cardiopatia de alta incidência na clínica médica de pequenos animais, acometendo mormente cães idosos e raças de pequeno porte. Desta forma, foi realizada uma investigação científica objetivando avaliar clinicamente a utilização dos fármacos maleato de enalapril e furosemida em cães com a referida enfermidade na classe funcional Ib da ICC, antes e após a terapêutica implantada. Para isso, utilizaram-se 16 cães portadores da valvulopatia supracitada, distribuídos em dois grupos; com o primeiro recebendo furosemida (n=8) e o segundo maleato de enalapril (n=8), durante 56 dias. Os cães foram avaliados em quatro momentos (T0, T14, T28 e T56 dias) quanto aos sinais clínicos e parâmetros hematológicos e bioquímico-séricos, que incluíram concentrações séricas da enzima conversora da angiotensina (ECA) e aldosterona, como também avaliações radiográficas, eletrocardiográficas, ecodopplercardiográficas e da pressão arterial. Os resultados quanto aos parâmetros clínicos, avaliações hematológicas e bioquímicas séricas não revelaram alterações significativas em ambos os grupos, mas reduções significativas nos valores de ECA e aldosterona no grupo que recebeu o maleato de enalapril foram identificadas. Ao exame radiográfico observou-se reduções nos valores de VHS e na variável onda Pms do eletrocardiograma em ambos os grupos, mas sem alterações nos valores da pressão arterial. Por sua vez, o ecodopplercardiograma evidenciou diminuição significativa das variáveis DIVEd/s nos grupos estudados e na FEC% nos cães que receberam somente enalapril. Portanto, a análise dos resultados encontrados indicou que a monoterapia fundamentada no maleato de enalapril apresentou melhor eficiência no controle do quadro clínico em pacientes da classe funcional Ib da ICC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os dentes de cutias (Dasyprocta azarae) foram descritos macroscopicamente para fornecer informações sobre um dos maiores roedores das Américas. Radiografias foram realizadas em seis cabeças, e os dentes foram descritos. O esmalte envolve a dentina coronal e se projeta até a raiz e é presente como lâminas dispostas paralelamente em direção vestíbulolingual. A dentina é localizada entre as lâminas do esmalte e envolve os cornos pulpares. O cemento é localizado internamente às lâminas de esmalte. Na superfície lingual, o cemento e a dentina são os elementos mais externos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avaliaram-se oito articulações metacarpofalangeanas (MCF) de eqüinos adultos pelos exames radiográfico e ultra-sonográfico após indução cirúrgica de uma instabilidade articular, para mimetizar as alterações iniciais da osteoartrite (OA) naturalmente adquirida. Foram mensurados a circunferência articular, a amplitude do movimento articular e o grau de claudicação dos membros torácicos (avaliação clínica). Dez dias após a intervenção cirúrgica os animais foram exercitados em um andador por um período de 60 dias. Os exames radiográfico e ultra-sonográfico foram realizados antes da intervenção cirúrgica e após 25, 40 e 70 dias, e a avaliação clínica, semanalmente, durante todo o período experimental. Observaram-se alterações ultra-sonográficas aos 25 dias após a instabilidade articular, enquanto as alterações radiográficas somente foram visualizadas aos 40 dias. Houve aumento significativo (P<0,05) da circunferência articular da articulação MCF operada (25,75cm± 1,1) a partir do sétimo dia, em relação à articulação controle (24,88cm± 1,0) e diminuição da amplitude do movimento da articulação operada (96,38º± 10,7) a partir do 25º dia, em relação ao seu valor basal (109,24º± 10,3) e em relação ao controle (108,75º± 8,3). O grau de claudicação aumentou significativamente (P<0,05) durante o período do estudo, com valor médio do escore de 1,5 para o membro operado em relação ao membro contralateral. em conclusão, os sinais iniciais da OA cirurgicamente induzida foram melhor e mais precocemente detectados pela ultra-sonografia quando comparado ao exame radiografico. As mensurações da circunferência articular e da amplitude do movimento articular são úteis na avaliação das doenças articulares.