166 resultados para Analog multipliers.
Resumo:
In some mares with lesions of the reproductive tract, embryo collection and survival rates are low or collection of embryos is not feasible. For these mares, oocyte transfer has been proposed as a method to induce pregnancies. In this report, a method for oocyte transfer in mares and results of oocyte transfer performed over 2 breeding seasons, using mares with long histories of subfertility and various reproductive lesions, are described.Human chorionic gonadotropin or an implant containing a gonadotropin-releasing hormone analog was used to initiate follicular and oocyte maturation. Oocytes were collected by means of transvaginal ultrasound-guided follicular aspiration. Following follicular aspiration, cumulus oocyte complexes were evaluated for cumulus expansion and signs of atresia; immature oocytes were cultured in vitro to allow maturation. The recipient's ovary and uterine tube (oviduct) were exposed through a flank laparotomy with the horse standing, and the oocyte was slowly deposited within the oviduct. Oocyte transfer was attempted in 38 mares between 9 and 30 years old during 2 successive breeding seasons. All mares had a history of reproductive failure while in breeding and embryo transfer programs. Twenty pregnancies were induced. Fourteen of the pregnant mares delivered live foals. Results suggest that oocyte transfer can be a successful method for inducing pregnancy in subfertile mares in a commercial setting..
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)-with a profilometer and AutoCAD software. Materials and Methods: Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P <= .05 considered significant. Results: For implants perpendicular to the horizontal surface of the specimen (90 degrees), there were no significant differences between the mean measurements obtained with the profilometer (90.04 degrees) and AutoCAD (89.95 degrees; P=.9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P=.0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). Conclusions: The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.
Resumo:
Different transfer impression techniques for implant-supported prostheses have been suggested to obtain a working cast. This article describes and illustrates clinical and laboratory pros-thodontic procedures to transfer implant positions with splinted transfer copings and without impression material to form a laboratory analog transfer template. With this technique, a preliminary cast is modified to place the analogs according to a corrected position and obtain the master cast. Although this technique does not record adjacent tissues, it is a simple procedure, less time consuming, and easily performed.
Resumo:
Objective: To evaluate patients' perceptions of alterations occurring after chin bone harvesting.Materials and Methods: Thirty patients were evaluated subjectively by visual analog scale-related sensitivity, facial aesthetics, eating, speaking, and lower lip movement, during 12 months. Objective analysis used the static light touch neurosensorial test. The statistical analysis was executed with Friedman test with P < 0.05 for both samples.Results: Subjective analysis revealed no alterations (1) to facial aesthetics, eating, speaking or lower lip movement but sensitivity of the mental region went from a lot of alteration initially (5) to little at the end of the study (3). Objective analysis results showed normal sensitivity (1) in the region after 12 months.Conclusion: The discrepancy between subjective and objective analyses may be indicative of the limited precision of clinical testing for subjective impressions assessment. (Implant Dent 2012;21:411-414)
Resumo:
Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of a stone index and of 3 impression techniques (tapered impression copings, squared impression copings, and squared impression copings splinted with acrylic resin) associated with 3 pouring techniques (conventional, pouring using latex tubes fitted onto analogs, and pouring after joining the analogs with acrylic resin) for implant-supported prostheses. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutment analogs, a framework, and 2 aluminum custom trays were fabricated. Polyether impression material was used for all impressions. Ten groups were formed (a control group and 9 test groups formed by combining each pouring technique and impression technique). Five casts were made per group for a total of 50 casts and 200 gap values (1 gap value for each implant-abutment analog). Results: The mean gap value with the index technique was 27.07 mu m. With the conventional pouring technique, the mean gap values were 116.97 mu m for the tapered group, 5784 mu m for the squared group, and 73.17 mu m for the squared splinted group. With pouring using latex tubes, the mean gap values were 65.69 mu m for the tapered group, 38.03 mu m for the squared group, and 82.47 mu m for the squared splinted group. With pouring after joining the analogs with acrylic resin, the mean gap values were 141.12 jum for the tapered group, 74.19 mu m for the squared group, and 104.67 mu m for the squared splinted group. No significant difference was detected among Index, squarellatex techniques, and master cast (P > .05). Conclusions: The most accurate impression technique utilized squared copings. The most accurate pouring technique for making the impression with tapered or squared copings utilized latex tubes. The pouring did not influence the accuracy of the stone casts when using splinted squared impression copings. Either the index technique or the use of squared coping combined with the latex-tube pouring technique are preferred methods for making implant-supported fixed restorations with dimensional accuracy.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Recent interest in the annexin 1 field has come from the notion that specific G-protein-coupled receptors, members of the formyl-peptide receptor (FPR) family, appear to mediate the anti-inflammatory actions of this endogenous mediator. Administration of the annexin 1 N-terminal derived peptide Ac2-26 to mice after 25 min ischemia significantly attenuated the extent of acute myocardial injury as assessed 60 min postreperfusion. Evident at the dose of 1 mg/kg (similar to9 nmol per animal), peptide Ac2-26 cardioprotection was intact in FPR null mice. Similarly, peptide Ac2-26 inhibition of specific markers of heart injury (specifically myeloperoxidase activity, CXC chemokine KC contents, and endogenous annexin 1 protein expression) was virtually identical in heart samples collected from wild-type and FPR null mice. Mouse myocardium expressed the mRNA for FPR and the structurally related lipoxin A(4) receptor, termed ALX; thus, comparable equimolar doses of two ALX agonists (W peptide and a stable lipoxin A4 analog) exerted cardioprotection in wild-type and FPR null mice to an equal extent. Curiously, marked (>95%) blood neutropenia produced by an anti-mouse neutrophil serum did not modify the extent of acute heart injury, whereas it prevented the protection afforded by peptide Ac2-26. Thus, this study sheds light on the receptor mechanism(s) mediating annexin 1-induced cardioprotection and shows a pivotal role for ALX and circulating neutrophil, whereas it excludes any functional involvement of mouse FPR. These mechanistic data can help in developing novel therapeutics for acute cardioprotection.
Resumo:
ADP-glucose pyrophosphorylase is the key regulatory enzyme in the biosynthesis of starch in plants and glycogen in bacteria. The enzyme from potato tuber is comprised of a regulatory subunit and a catalytic subunit and is present as a heterotetramer (alpha(2)beta(2)) the catalytic subunit from potato tuber (50 kDa) was crystallized in four different forms, two of which are suitable for structural studies. A tetragonal crystal form obtained in the presence of the substrate analog Cr-ATP diffracted to 2.2 Angstrom and belongs to space group P4(1) (or its enantiomorph), with unit-cell parameters a = b = 110.57, c = 190.14 Angstrom. A second crystal form obtained diffracted to 2.8 Angstrom and belongs to space group PZ, with unit-eel parameters a = 80.06, b = 138.84, c = 92.20 Angstrom, beta = 112.40 degrees. As this protein displays no significant homology to any currently known protein structure, a search for heavy-atom derivatives has been initiated.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A performance comparison between a recently proposed novel technique known as fast orthogonal frequency-division multiplexing (FOFDM) and conventional orthogonal frequency-division multiplexing (OFDM) is undertaken over unamplified, intensity-modulated, and direct-detected directly modulated laser-based optical signals. Key transceiver parameters, such as the maximum achievable transmission capacity and the digital-to-analog/analog-to-digital converter (DAC/ADC) effects are explored thoroughly. It is shown that, similarly to conventional OFDM, the least complex and bandwidth efficient FOFDM can support up to similar to 20 Gb/s over 500 m worst-case multimode fiber (MMF) links having 3 dB effective bandwidths of similar to 200 MHz X km. For compensation of the DAC/ADC roll-off, a power-loading (PL) algorithm is adopted, leading to an FOFDM system improvement of similar to 4 dB. FOFDM and conventional OFDM give similar optimum DAC/ADC parameters over 500 m worst-case MMF, while over 50 km single-mode fiber a maximum deviation of only similar to 1 dB in clipping ratio is observed due to the imperfect chromatic dispersion compensation caused by one-tap equalizers.
Resumo:
OBJETIVO: Comparar os tempos de geração e digitação de laudos radiológicos entre um sistema eletrônico baseado na tecnologia de voz sobre o protocolo de internet (VoIP) e o sistema tradicional, em que o radiologista escreve o laudo à mão. MATERIAIS E MÉTODOS: Foi necessário modelar, construir e implantar o sistema eletrônico proposto, capaz de gravar o laudo em formato de áudio digital, e compará-lo com o tradicional já existente. Por meio de formulários, radiologistas e digitadores anotaram os tempos de geração e digitação dos laudos nos dois sistemas. RESULTADOS: Comparadas as médias dos tempos entre os sistemas, o eletrônico apresentou redução de 20% (p = 0,0410) do tempo médio de geração do laudo em comparação com o sistema tradicional. O tradicional foi mais eficiente em relação ao tempo de digitação, uma vez que a média de tempo do eletrônico foi três vezes maior (p < 0,0001). CONCLUSÃO: Os resultados mostraram diferença estatisticamente significante entre os sistemas comparados, sendo que o eletrônico foi mais eficiente do que o tradicional em relação ao tempo de geração dos laudos, porém, em relação ao tempo de digitação, o tradicional apresentou melhores resultados.
Resumo:
Purpose - This paper proposes an interpolating approach of the element-free Galerkin method (EFGM) coupled with a modified truncation scheme for solving Poisson's boundary value problems in domains involving material non-homogeneities. The suitability and efficiency of the proposed implementation are evaluated for a given set of test cases of electrostatic field in domains involving different material interfaces.Design/methodology/approach - the authors combined an interpolating approximation with a modified domain truncation scheme, which avoids additional techniques for enforcing the Dirichlet boundary conditions and for dealing with material interfaces usually employed in meshfree formulations.Findings - the local electric potential and field distributions were correctly described as well as the global quantities like the total potency and resistance. Since, the treatment of the material interfaces becomes practically the same for both the finite element method (FEM) and the proposed EFGM, FEM-oriented programs can, thus, be easily extended to provide EFGM approximations.Research limitations/implications - the robustness of the proposed formulation became evident from the error analyses of the local and global variables, including in the case of high-material discontinuity.Practical implications - the proposed approach has shown to be as robust as linear FEM. Thus, it becomes an attractive alternative, also because it avoids the use of additional techniques to deal with boundary/interface conditions commonly employed in meshfree formulations.Originality/value - This paper reintroduces the domain truncation in the EFGM context, but by using a set of interpolating shape functions the authors avoided the use of Lagrange multipliers as well Mathematics in Engineering high-material discontinuity.