96 resultados para Airflow resistivity
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper presents the results of electrical resistivity methods in the area delineation that was potentially contaminated by liquefaction products, which are also called putrefactive liquids in Vila Rezende municipal cemetery, Piracicaba, So Paulo, Brazil. The results indicate a depth of water table between 3.1 and 5.1 m, with two groundwater direction flows, one to the SW and another to the SE. Due to the contamination plumes, which have the same groundwater direction flow, as well the conductive anomalies observed in the geoelectric sections, the contamination suspicions in the area were confirmed. The probable plume to the SE extends beyond the limits of the cemetery. The location of the conductive anomalies and the probable contamination plumes showed that the contamination is linked with the depth of the water table and the burial time. Mapping using the geostatistical method of ordinary kriging applied to the work drew structural characteristics of the regional phenomenon and spatial behavior of the electrical resistivity data, resulting in continued surfaces. Thus, this method has proved to be an important tool for mapping contamination plumes in cemeteries.
Resumo:
Este trabalho mostra os resultados obtidos com a realização de ensaios geofísicos na em áreas de lavra de areia, no município de Descalvado, SP. O objetivo dos ensaios é o de detectar cavidades no interior de arenitos, pertencentes às Formações Pirambóia e Botucatu. Estas cavidades formaram-se com o rebaixamento do lençol freático, necessário para as operações de extração da areia. As técnicas geofísicas utilizadas foram: gravimetria, eletrorresistividade (caminhamento elétrico dipolo-dipolo) e radar de penetração no solo (GPR). Na primeira etapa dos trabalhos foram utilizados a gravimetria e a eletrorresistividade em uma bancada onde ocorreu um desmoronamento devido ao abatimento do teto de uma cavidade. Os resultados obtidos com estas duas técnicas foram coerentes pois a gravimetria mostrou baixos gravimétricos indicando uma ausência de massa na área de influência da cavidade e o caminhamento detectou um esperado aumento de resistividade elétrica nesta mesma área. Na segunda etapa, com a realização dos ensaios de GPR em uma bancada próxima à anterior, foi possível detectar cavidades por meio das feições hiperbólicas detectadas nos radargramas.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The order-disorder transformation in the Ni-4.49 at.% Al alloy was studied using electrical resistivity measurements, microhardness measurements, differential scanning calorimetry (DSC) and transmission electron microscopy (TEM). The results confirmed the ordering behavior expected for Ni-Al dilute alloys and the suggested relation between resistivity changes and microhardness changes with antiferromagnetic spin ordering. The higher value obtained for the activation energy of vacancy migration was associated with a decrease in the Al concentration gradient near solute-depleted regions. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The complete I-V characteristics of SnO(2)-based varistors, particularly of the Pianaro system SCNCr consisting in 98.9%SnO(2)+1%CoO+0.05%Nb(2)O(5)+0.05%Cr(2)O(3), all in mol%, have been seldom reported in the literature. A comparative study at low and high currents of the nonohmic behavior of SCNCr- and ZnO-based varistors (modified Matsuoka system) is proposed in this work. The SCNCr system showed higher nonlinearity coefficients in the whole range of measured current. The electrical breakdown field (E(b)) was twice as high for the SCNCr system (5400 V/cm) than for the ZnO varistor (2600 V/cm) due to a smaller average grain size of the former (4.5 mu m) with respect to the latter (8.5 mu m). Nevertheless, we consider that another important factor responsible for the high E(b) in the SCNCr system is the great number of electrically active interfaces (85%) as determined with electrostatic force microscopy (EFM). It was also established that the SCNCr system might be produced in disks of smaller dimensions than that of commercial ZnO-based product, with a 5.0 cm(-1) minimal area-volume (A/V) ratio. The SCNCr reached the saturation current in a short time because of the high resistivity of the grains, which is five times higher than that of the grains in ZnO-based varistors.
Resumo:
A caracterização do Sistema Aquífero Barreiras / Marituba, maior fonte de abastecimento de água da cidade de Maceió, capital de Alagoas, Brasil, é importante para fornecer subsídios para uma utilização racional e sustentável desse recurso. O arcabouço tectônico e estratigráfico da área construído por meio de perfis de poços, análise de elementos estruturais e mapeamento geológico propõe um modelo com uma série de grabens e horsts. Com o objetivo de confirmar a presença de estruturas delimitando blocos estruturais e refinar o modelo foram realizados ensaios de sondagem elétrica vertical e caminhamento elétrico dipolo-dipolo. Os resultados dos ensaios geofísicos confirmaram a existência de zonas mais condutoras, que caracterizam as zonas de falhas normais que delimitam os blocos estruturais. A integração dos dados geológicos e estruturais aos resultados geofísicos confirmaram a existência de um modelo estrutural com blocos escalonados, que influenciam fortemente o comportamento do sistema águas subterrâneas.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)