75 resultados para 3D deformation analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To investigate the reliability of regional three-dimensional registration and superimposition methods for assessment of temporomandibular joint condylar morphology across subjects and longitudinally.Methods: The sample consisted of cone beam CT scans of 36 patients. The across-subject comparisons included 12 controls, mean age 41.3 +/- 12.0 years, and 12 patients with temporomandibular joint osteoarthritis, mean age 41.3 +/- 14.7 years. The individual longitudinal assessments included 12 patients with temporomandibular joint osteoarthritis, mean age 37.8 +/- 16.7 years, followed up at pre-operative jaw surgery, immediately after and one-year post-operative. Surface models of all condyles were constructed from the cone beam CT scans. Two previously calibrated observers independently performed all registration methods. A landmark-based approach was used for the registration of across-subject condylar models, and temporomandibular joint osteoarthritis vs control group differences were computed with shape analysis. A voxel-based approach was used for registration of longitudinal scans calculated x, y, z degrees of freedom for translation and rotation. Two-way random intraclass correlation coefficients tested the interobserver reliability.Results: Statistically significant differences between the control group and the osteoarthritis group were consistently located on the lateral and medial poles for both observers. The interobserver differences were <= 0.2 mm. For individual longitudinal comparisons, the mean interobserver differences were <= 0.6 mm in translation errors and 1.2 degrees in rotation errors, with excellent reliability (intraclass correlation coefficient >0.75).Conclusions: Condylar registration for across-subjects and longitudinal assessments is reliable and can be used to quantify subtle bony differences in the three-dimensional condylar morphology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess 3D morphological variations and local and systemic biomarker profiles in subjects with a diagnosis of temporomandibular joint osteoarthritis (TMJ OA).Design: Twenty-eight patients with long-term TMJ OA (39.9 +/- 16 years), 12 patients at initial diagnosis of OA (47.4 +/- 16.1 years), and 12 healthy controls (41.8 +/- 12.2 years) were recruited. All patients were female and had cone beam CT scans taken. TMJ arthrocentesis and venipuncture were performed on 12 OA and 12 age-matched healthy controls. Serum and synovial fluid levels of 50 biomarkers of arthritic inflammation were quantified by protein microarrays. Shape Analysis MANCOVA tested statistical correlations between biomarker levels and variations in condylar morphology.Results: Compared with healthy controls, the OA average condyle was significantly smaller in all dimensions except its anterior surface, with areas indicative of bone resorption along the articular surface, particularly in the lateral pole. Synovial fluid levels of ANG, GDF15, TIMP-1, CXCL16, MMP-3 and MMP-7 were significantly correlated with bone apposition of the condylar anterior surface. Serum levels of ENA-78, MMP-3, PAI-1, VE-Cadherin, VEGF, GM-CSF, TGF beta b1, IFN gamma g, TNF alpha a, IL-1 alpha a, and IL-6 were significantly correlated with flattening of the lateral pole. Expression levels of ANG were significantly correlated with the articular morphology in healthy controls.Conclusions: Bone resorption at the articular surface, particularly at the lateral pole was statistically significant at initial diagnosis of TMJ OA. Synovial fluid levels of ANG, GDF15, TIMP-1, CXCL16, MMP-3 and MMP-7 were correlated with bone apposition. Serum levels of ENA-78, MMP-3, PAI-1, VE-Cadherin, VEGF, GM-CSF, TGF beta 1, IFN gamma, TNF alpha, IL-1 alpha, and IL-6 were correlated with bone resorption. Published by Elsevier Ltd on behalf of Osteoarthritis Research Society International.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, natural frequencies were analyzed (axial, torsional and flexural) and frequency response of a vertical rotor with a hard disk at the edge through the classical modal and complex analysis. The equation that rules the movement was obtained through the Lagrangian formulation. The model considered the effects of bending, torsion and axial deformation of the shaft, besides the gravitational and gyroscopic effects. The finite element method was used to discretize the structure into hollow cylindrical elements with 12 degrees of freedom. Mass, stiffness and gyroscopic matrices were explained consistently. The classical modal analysis, usually applied to stationary structures, does not consider an important characteristic of rotating machinery which are the methods of forward and backward whirl. Initially, through the traditional modal analysis, axial and torsional natural frequencies were obtained in a static shaft, since they do not suffer the influence of gyroscopic effects. Later research was performed by complex modal analysis. This type of tool, based on the use of complex coordinates to describe the dynamic behavior of rotating shaft, allows the decomposition of the system in two submodes, backward and forward. Thus, it is possible to clearly visualize that the orbit and direction of the precessional motion around the line of the rotating shaft is not deformed. A finite element program was developed using MATLAB (TM) and numerical simulations were performed to validate this model. Natural frequencies and directional frequency forced response (dFRF) were obtained using the complex modal analysis for a simple vertical rotor and also for a typical drill string used in the construction of oil wells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Throughout the history of medicine surgeons realized the importance of the patella to the functioning of the knee. The main function of the patella is to increase the mechanical efficiency of the quadriceps tendon and knee extensor mechanism. It was found that 50% to 80% of the fractures without deviation of the patella have the transversal pattern, possibly due to excessive tensile forces applied to the extensor mechanism. The purpose of this study is to analyze the loads to which a patella is submitted during a normal extension movement of knee. This analysis will be done by modeling a 3D patella and subsequent load simulation as, described in medical literature, using the finite element method

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Namorado Oil Field represents the beginning of the oil exploration in Brazil, in the 70s, and it is still a subject of researches because the importance of this turbidite sandstone in the brazilian oil production. The Namorado’s production level was denominated “Namorado sandstone”, it is composed by turbidite sandstone deposited during the Albian-Cenomanian. In order to define the structural geometry of the main reservoir, geological and geophysical tools like RECON and Geographix (Prizm – Seisvision) softwares were used, and its application was focused on geological facies analysis, for that propose well logs, seismic interpretation and petrophysical calculations were applied. Along this work 15 vertical wells were used and the facies reservoirs were mapped of along the oil field; it is important to mentioned that the all the facies were calibrated by the correlation rock vs log profile, and 12 reservoir-levels (NA-1, NA-2, NA-3, NA-4, NA-5, NA-6, NA-7, NA-8, NA-9, NA-10, NA-11 e NA-12) were recognized and interpreted. Stratigraphic sections (NE-SW and NW-SE) were also built based on stratigraphic well correlation of each interpreted level, and seismic interpretation (pseudo-3D seismic data) on the southeastern portion of the oil field. As results it was interpreted on two- and three-dimensional maps that the deposition reservoir’s levels are hight controlled by normal faults systems. This research also shows attribute maps interpretation and its relationship with the selection of the reservoir attribute represented on it. Finally the data integration of stratigraphic, geophysical and petrophysical calculations lets us the possibility of obtain a detail geological/petrophysical 3D model of the main reservoir levels of “Namorado sandstone” inside the oil/gás field

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Malformations and possible damages to the urogenital system can be originated in the embryonic period. Moreover, fire guns, knives and accidents, where there is the disruption of the urethra, also cause these lesions. The objective was to analyze the contribution of tissue engineering in the construction of neo-urethra, developed by bioengineering. We performed an urothelial ex vivo expansion of cells in 3D scaffolds (platelet gel matrix and acellular porcine aorta) to assess the contribution of this technique in the construction of a neo-urethra. Mechanical dissociation was made of the inner wall of 10 North Folk rabbit’s bladder, weighing 2.5 to 3.0 kg. After dissociation the cell content was centrifuged and obtained a pellet of urothelial cells. The pellet was ressuspended in culture medium DMEM F12 and cells were maintained in culture for 15 days. Immunohistochemical analysis characterized the urothelial culture. The cells were then implanted in the scaffold - platelet gel. In a second experiment using aortic porcine acellular matrix were implanted urothelial cells alone and urothelial cells on platelet gel, on the inner wall of the scaffold - aorta, with space for setting bordered by a urethral probe. The complex probe - cells - aorta and probe - cells in platelet gel - aorta, were sealed with suture material and culture were maintained in a humidified 37ºC incubator with 5% CO2 in air for 12 days to subsequent histological analysis of urothelium cell adhesion to the scaffolds. By observation under an optical microscope, we could see the growth of cells in the scaffold platelet gel, from a monolayer in to a three-dimensional structure. In the acellular porcine aortic matrix containing the platelet gel, we could observe a few quantity of urothelial cells adhered. However with the acellular porcine aortic matrix in which was implanted only the urothelial cells, we have obtained adhesion to the wall

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to use the finite element method to evaluate the distribution of stresses and strains on the local bone tissue adjacent to the miniplate used for anchorage of orthodontic forces. Methods: A 3-dimensional model composed of a hemimandible and teeth was constructed using dental computed tomographic images, in which we assembled a miniplate with fixation screws. The uprighting and mesial movements of the mandibular second molar that was anchored with the miniplate were simulated. The miniplate was loaded with horizontal forces of 2, 5, and 15 N. A moment of 11.77 N.mm was also applied. The stress and strain distributions were analyzed, and their correlations with the bone remodeling criteria and miniplate stability were assessed. Results: When orthodontic loads were applied, peak bone strain remained within the range of bone homeostasis (100-1500 mu m strain) with a balance between bone formation and resorption. The maximum deformation was found to be 1035 mu m strain with a force of 5 N. At a force of 15 N, bone resorption was observed in the region of the screws. Conclusions: We observed more stress concentration around the screws than in the cancellous bone. The levels of stress and strain increased when the force was increased but remained within physiologic levels. The anchorage system of miniplate and screws could withstand the orthodontic forces, which did not affect the stability of the miniplate.