221 resultados para (13)CD(3) OH


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to improve the current chemotherapy of Giardia infection, potential antigiardial agents have been screened, including natural products. Propolis, a resinous hive product collected by bees, has attracted attention as a useful and popular substance with several therapeutic activities. The present study was carried out aiming to evaluate the in vitro effects of an ethanolic extract of propolis on the growth and adherence of Giardia duodenalis trophozoites. Propolis inhibited the growth of trophozoites and the level of inhibition varied according to the extract concentration and incubation times. The highest reduction of parasite growth was observed in cultures exposed to 125, 250 and 500 mu g/ml of propolis, in all incubation periods (24, 48, 72 and 96 h). Growth reduction by 50% was observed in 125 mu g/ml propolis-treated cultures, while the concentrations of 250 and 500 mu g/ml were able to inhibit growth by more than 60%. Propolis also inhibited parasite adherence and all assayed propolis concentrations promoted the detachment of trophozoites. Light microscope observations revealed changes of the pear-shaped aspect of the cell and reduction of flagellar beating frequency in the great part of the trophozoites. Our results hold the perspective for the utilization of propolis as an antigiardial agent. (c) 2005 Elsevier GmbH. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Physical exercises have been recommended in the prevention of non-insulin dependent diabetes mellitus (NIDDM), but the mechanisms involved in this intervention are not yet fully understood. Experimental models offer the opportunity for the study of this matter. The present study was designed to analyze the diabetes evolution in rats submitted to neonatal treatment with alloxan with the objective of verifying the suitability of the model to future studies with exercises. For this, newly born rats (6 days old) received intraperitoneal alloxan (A = 200 mg/kg of body weight). Rats injected with vehicle (citrate buffer) were used as controls (C). The fasting blood glucose level (mg/dL) was higher in the alloxan group at the day 28 (C=47.25 +/- 5.08; A=54.51 +/- 7.03) but not at the 60 day of age (C=69.18 +/- 8.31; A=66.81 +/- 6.08). The alloxan group presented higher blood glucose level during glucose tolerance test (GTT) (mg/dL. 120 min) in relation to the control group both at day 28 (C=16908.9 +/- 1078.8; A=21737,7 +/- 1106.4) and at day 60 (C=11463.45 +/- 655.30; A=15282.21 +/- 1221.84). Insulinaemia during GTT (ng/mL.120 min) was lower at day 28 (C=158.67 +/- 33.34; A=123.90 +/- 19.80), but presented no difference at day 60 (C=118.83 +/- 26.02; A=97.8 +/- 10.88). At day 60, the glycogen concentration in the soleus muscle (mg/100mg) was lower in the alloxan group (0.3 +/- 0.13) in relation to the control group (0.5 +/- 0.07). No difference was observed between groups in relation to (mu mol/g.h): Glucose Uptake (C = 5.8 +/- 0.63; A = 5.2 +/- 0.73); Glucose Oxidation (C= 4.3 +/- 1.13; A= 3.9 +/- 0.44); Glycogen Synthesis (C= 0.8 +/- 0.18; A= 0.7 +/- 0.18) and Lactate Production (C= 3.8 +/- 0.8; A= 3.8 0.7) by the isolated soleus muscle. The glucose-stimulated insulin secretion (16.7mM) by the isolated islets (ng/5 islets. h) of the alloxan group was lower (14.3 +/- 4.7) than the control group (32.0 +/- 7.9). Thus, we may conclude that this neonatal diabetes induction model gathers interesting characteristics and may be useful for further studies on the role of the exercise in the diabetes mellitus appearance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O principal objetivo deste estudo foi verificar o efeito do nível de performance aeróbia na relação entre os índices técnicos correspondentes à velocidade crítica (VC) e à velocidade máxima de 30 minutos (V30) em nadadores. Participaram deste estudo, 23 nadadores do gênero masculino com características antropométricas similares, divididos segundo o nível de performance aeróbia em grupo G1 (maior performance) (n = 13) e G2 (menor performance) (n = 10). Os indivíduos tinham pelo menos quatro anos de experiência no esporte e treinavam um volume semanal de 30.000 a 45.000m. A VC foi determinada através do coeficiente angular da regressão linear entre as distâncias (200 e 400m) e seus respectivos tempos. A V30 foi determinada através da máxima distância realizada em um teste de 30 minutos. Todas as variáveis foram determinadas no nado crawl. A VC foi significantemente maior do que a V30 no grupo G1 (1,30 ± 0,04 vs. 1,23 ± 0,06m.s-1) e no G2 (1,17 ± 0,08 vs. 1,07 ± 0,06m.s-1). As duas variáveis foram maiores no grupo G1. As taxas de braçada correspondentes à VC (TBVC) e à V30 (TBV30) obtidas nos grupos G1 (33,07 ± 4,34 vs. 31,38 ± 4,15 ciclos.min-1) e G2 (35,57 ± 6,52 vs. 33,54 ± 5,89 ciclos.min-1) foram similares entre si. A TBVC foi significantemente menor no grupo 1 do que no grupo 2, enquanto que a TBV30 não foi diferente entre os grupos. Os comprimentos de braçada correspondentes à VC (CBVC) e à V30 (CBV30) foram significantemente maiores no grupo G1 (2,41 ± 0,33 vs. 2,38 ± 0,30m.ciclo-1) do que no G2 (2,04 ± 0,43 vs. 1,97 ± 0,40m.ciclo-1), e similares entre si nos dois grupos. As correlações (r) entre a VC e a V30 e as variáveis técnicas correspondentes às duas velocidades foram significantes em todas as comparações (0,68 a 0,91). Portanto, a relação entre a velocidade e as variáveis técnicas correspondentes à VC e à V30 não é modificada pelo nível de performance aeróbia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo do presente estudo foi desenvolver um snorquel (SNQ) de baixo custo para mensuração de parâmetros cardiorrespiratórios em natação. Para isso, a máscara do analisador de gases VO2000 (MASC) foi adaptada a um SNQ desenvolvido artesanalmente com espaço morto de 250ml. Oito participantes foram submetidos a dois testes incrementais (TI) em cicloergômetro utilizando a MASC e o SNQ. Os TI foram realizados até a exaustão voluntária e foram compostos por estágios de 3min com carga inicial e incrementos de 35W. em ambas as situações, amostras gasosas foram coletadas em intervalos de 10s para determinação dos volumes de oxigênio (VO2), gás carbônico (VCO2), ventilatório (VE) e mensuração da freqüência cardíaca (FC). A comparação dos parâmetros cardiorrespiratórios (VO2, VE, VCO2 e FC) mensurados com o SNQ e a MASC foi realizada com o teste t de Student para amostras dependentes, enquanto que o teste de correlação de Pearson e a análise gráfica de Bland e Altman foram utilizados para verificar as associações e concordância entre parâmetros. em todos os casos, o nível de significância foi de P < 0,05. A adequação das equações de correção para os valores provenientes do SNQ foi verificada pelos erros sistemáticos (bias), aleatórios (precisão) e acurácia (ac). Não foram observadas diferenças significativas entre os valores de VO2, VCO2 e FC obtidos com a MASC e SNQ. Os valores de VE mensurados com o SNQ foram significativamente superiores aos obtidos com a MASC. No entanto, todos os parâmetros apresentaram elevada concordância e coeficiente de correlação (0,88 a 0,97). Além disso, foram verificados reduzidos valores de bias (VO2 = 0,11L/min; VE = 4,11L/min; VCO2 = 0,54L/min; 8,87bpm), precisão (VO2 = 0,24L/min; VE = 11,02L/ min; VCO2 = 0,18L/min; 7,42bpm) e ac (VO2 = 0,27L/min; VE = 11,76L/min; VCO2 = 0,56L/min; 11,56bpm). Desse modo, pode-se concluir que o SNQ desenvolvido neste estudo possibilita a mensuração válida de parâmetros cardiorrespiratórios em natação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The X-ray crystal structure of a complex between ribonuclease T-1 and guanylyl(3'-6')-6'-deoxyhomouridine (GpcU) has been determined at 2.0 Angstrom resolution. This Ligand is an isosteric analogue of the minimal RNA substrate, guanylyl(3'-5')uridine (GpU), where a methylene is substituted for the uridine 5'-oxygen atom. Two protein molecules are part of the asymmetric unit and both have a GpcU bound at the active site in the same manner. The protein-protein interface reveals an extended aromatic stack involving both guanines and three enzyme phenolic groups. A third GpcU has its guanine moiety stacked on His92 at the active site on enzyme molecule A and interacts with GpcU on molecule B in a neighboring unit via hydrogen bonding between uridine ribose 2'- and 3'-OH groups. None of the uridine moieties of the three GpcU molecules in the asymmetric unit interacts directly with the protein. GpcU-active-site interactions involve extensive hydrogen bonding of the guanine moiety at the primary recognition site and of the guanosine 2'-hydroxyl group with His40 and Glu58. on the other hand, the phosphonate group is weakly bound only by a single hydrogen bond with Tyr38, unlike ligand phosphate groups of other substrate analogues and 3'-GMP, which hydrogen-bonded with three additional active-site residues. Hydrogen bonding of the guanylyl 2'-OH group and the phosphonate moiety is essentially the same as that recently observed for a novel structure of a RNase T-1-3'-GMP complex obtained immediately after in situ hydrolysis of exo-(S-p)-guanosine 2',3'-cyclophosphorothioate [Zegers et al. (1998) Nature Struct. Biol. 5, 280-283]. It is likely that GpcU at the active site represents a nonproductive binding mode for GpU [:Steyaert, J., and Engleborghs (1995) fur. J. Biochem. 233, 140-144]. The results suggest that the active site of ribonuclease T-1 is adapted for optimal tight binding of both the guanylyl 2'-OH and phosphate groups (of GpU) only in the transition state for catalytic transesterification, which is stabilized by adjacent binding of the leaving nucleoside (U) group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of sonication on fluorescence probe solubilization in cationic vesicles of dioctadecyldimethylammonium bromide (DODAB) was investigated by steady-state fluorescence of pyrene (Py), trans-diphenylpolyenes-diphenylbutadiene (DPB), diphenylhexatriene (DPH), and their corresponding 4,4'-dialkyl derivatives 4B4A and 4H4A fluorescence probes. The data indicate that sonication affects the bilayer polarity, the melting temperature (T (m)), and the cooperativity of the melting process due to changes in vesicle morphology. The effect of temperature on the fluorescence intensity and yielding I broken vertical bar(f) and anisotropy < r > shows that the ionizable probes 4B4A and 4H4A are solubilized close to the vesicle interfaces, whereas the non-ionizable DPH and DPB are deeper in the bilayers. Py solubilization indicates that sonicated vesicles exhibit less densely packed bilayers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The efficacy of fluorescence spectroscopy to detect squamous cell carcinoma is evaluated in an animal model following laser excitation at 442 and 532 nm. Lesions are chemically induced with a topical DMBA application at the left lateral tongue of Golden Syrian hamsters. The animals are investigated every 2 weeks after the 4th week of induction until a total of 26 weeks. The right lateral tongue of each animal is considered as a control site (normal contralateral tissue) and the induced lesions are analyzed as a set of points covering the entire clinically detectable area. Based on fluorescence spectral differences, four indices are determined to discriminate normal and carcinoma tissues, based on intraspectral analysis. The spectral data are also analyzed using a multivariate data analysis and the results are compared with histology as the diagnostic gold standard. The best result achieved is for blue excitation using the KNN (K-nearest neighbor, a interspectral analysis) algorithm with a sensitivity of 95.7% and a specificity of 91.6%. These high indices indicate that fluorescence spectroscopy may constitute a fast noninvasive auxiliary tool for diagnostic of cancer within the oral cavity. (C) 2008 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of cutting initiation location and cutting speed on the bond strength between resin cement and feldspathic ceramic.Materials and Methods: Thirty-six blocks (6.4 x 6.4 x 4.8 mm) of ceramic (Vita VM7) were produced. The ceramic surfaces were etched with 10% hydrofluoric acid gel for 60 s and then silanized. Each ceramic block was placed in a silicon mold with the treated surface exposed. A resin cement (Variolink II) was injected into the mold over the treated surface and polymerized. The resin cement-ceramic blocks were divided into two groups according to experimental conditions: a) cutting initiation location - resin cement, ceramic and interface; and b) cutting speed - 10,000, 15,000, and 20,000 rpm. The blocks were sectioned to achieve non-trimmed bar specimens. The microtensile test was performed in a universal testing machine (1 mm/min). The failure modes were examined using an optical light microscope and SEM. Bond strength results were analyzed using one-way ANOVA and Tukey's test (alpha = 0.05).Results: Significant influences of cutting speed and initiation location on bond strength (p < 0.05) were observed. The highest mean was achieved for specimens cut at 15,000 rpm at the interface (15.12 +/- 5.36 MPa). The lowest means were obtained for specimens cut at the highest cutting speed in resin cement (8.50 +/- 3.27 MPa), and cut at the lowest cutting speed in ceramic (8.60 +/- 2.65MPa). All groups showed mainly mixed failure (75% to 100%).Conclusion: The cutting speed and initiation location are important factors that should be considered during specimen preparation for microtensile bond strength testing, as both may influence the bond strength results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study evaluated the efficacy of the union between two new self-etching self-adhesive resin cements and enamel using the microtensile bond strength test.Materials and Methods: Buccal enamel of 80 bovine teeth was submitted to finishing and polishing with metallographic paper to a refinement of #600, in order to obtain a 5-mm(2) flat area. Blocks (2 x 4 x 4 mm) of laboratory composite resin were cemented to enamel according to different protocols: (1) untreated enamel + RelyX Unicem cement (RX group); (2) untreated enamel + Bifix SE cement (BF group); (3) enamel acid etching and application of resin adhesive Single Bond + RelyX Unicem (RXA group); (4) enamel acid etching and application of resin adhesive Solobond M + Bifix SE (BFA group). After 7 days of storage in distillated water at 37 degrees C, the blocks were sectioned for obtaining microbar specimens with an adhesive area of 1 mm(2) (n = 120). Specimens were submitted to the microtensile bond strength test at a crosshead speed of 0.5 mm/min. The results (in MPa) were analyzed statistically by ANOVA and Tu key's test.Results: Enamel pre-treatment with phosphoric acid and resin adhesive (27.9 and 30.3 for RXA and BFA groups) significantly improved (p <= 0.05) the adhesion of both cements to enamel compared to the union achieved with as-polished enamel (9.9 and 6.0 for RX and BF).Conclusion: Enamel pre-treatment with acid etching and the application of resin adhesive significantly improved the bond efficacy of both luting agents compared to the union achieved with as-polished enamel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the bond strength of indirect restorations to dentin using self-adhesive cements with and without the application of adhesive systems.Material and Methods: Seventy-two bovine incisors were used, in which the buccal surfaces were ground down to expose an area of dentin measuring a minimum of 4 x 4 mm. The indirect resin composite Resilab was used to make 72 blocks, which were cemented onto the dentin surface of the teeth and divided into 4 groups (n = 18): group 1: self-adhesive resin cement BiFix SE, applied according to manufacturer's recommendations; group 2: self-adhesive resin cement RelyX Unicem, used according to manufacturer's recommendations; group 3: etch-and-rinse Solobond M adhesive system + BiFix SE; group 4: etch-and-rinse Single Bond 2 adhesive system + RelyX Unicem. The specimens were sectioned into sticks and subjected to microtensile testing in a universal testing machine (EMIC DL-200MF). Data were subjected to one-way ANOVA and Tukey's test (alpha = 5%).Results: The mean values (+/- standard deviation) obtained for the groups were: group 1: 15.28 (+/- 8.17)(a), group 2: 14.60 (+/- 5.21)(a), group 3: 39.20 (+/- 9.98)(c), group 4: 27.59 (+/- 6.57)(b). Different letters indicate significant differences (ANOVA; p = 0.0000).Conclusion: The application of adhesive systems before self-adhesive cements significantly increased the bond strength to dentin. In group 2, RelyX Unicem associated with the adhesive system Single Bond 2 showed significantly lower mean tensile bond strengths than group 3 (BiFix SE associated with the etch-and-rinse Solobond M adhesive system).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a measurement of the W boson pair-production cross section in p(p) over bar collisions at a center-of-mass energy of root s=1.96 TeV. The data, collected with the Run II D0 detector at Fermilab, correspond to an integrated luminosity of 224-252 pb(-1) depending on the final state (ee, e mu, or mu mu). We observe 25 candidates with a background expectation of 8.1 +/- 0.6(stat)+/- 0.6(syst)+/- 0.5(lum) events. The probability for an upward fluctuation of the background to produce the observed signal is 2.3x10(-7), equivalent to 5.2 standard deviations. The measurement yields a cross section of 13.8(-3.8)(+4.3)(stat)(-0.9)(+1.2)(syst)+/- 0.9(lum) pb, in agreement with predictions from the standard model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This investigation utilized hydrochemical relations to evaluate possible anthropogenic inputs at Meio Stream, São Paulo State. Realized three sampling of water during the months of February, April and July/2005, in five sampling points analyzing: discharge, temperature, turbidity, pH, electrical conductivity (EC), dissolved oxygen ( DO), TDS (total dissolved solids), TSS (total suspended solids), Ca(2+), Mg(2+), Na(+), K(+), HCO(3)(-), Cl(-), SO(4)(2-), PO(4)(3-) and NO(3)(-). The characteristics of water close to spring until Leme city allow concluding that there is a small interference in its quality, however the absence of treatment of domestic wastewater at Leme city reduced its quality. It was applied the QUAL 2K modeling to evaluate the Meio Stream auto-purification identified the auto-purification zones and indicated the necessity of secondary wastewater treatment, with 76% of efficiency.