669 resultados para radiographic zooming
Resumo:
Of the four lacustrine deltaic models, which were found in the Pendência formation, two are represented in the Serraria field. Respectively the deltaic models 1 and 3 shows the reservoir zones A and B. The Zone A is divided into six sub-areas. Each is representing a smaller cycle of development of sigmoidal lobes of deltaic front. Zone B produces in reservoirs of Model 3, or so called Full delta. The Zone B is formed by overlapping the deltaic plain system over the deltaic/prodeltaic front (model 1). This work uses the method of zooming with the aim to contextualize the geometric aspects of the sand bodies, highlighting the analysis of facies and diagenesis with help of pictures and testimonies of thin sections. The sigmoidal lobes of Zone A are fine to very fine sandstones, well sorted, with a arcosian composition.;practically with a weak compaction and cementation of a kind of film of clay (if very fine) and overgrowth feldspar (fine texture). This silicate phases are succeeded by cementation of poiquilotópica calcite, and after this a stage of dissolution, containing only regular permoporosity for this reservoir. Zone B has a combination of two types of deltaic plain reservoir. One is the rarest of distributary channel and the other the most common of lobes of crevasse. In the channel coarse to medium-grained and poor to moderate sorted sandstones are formed (tuning up), and with a lytic arcosiana nature. Rarely there are cements, including growth of feldspar and rhombohedral dolomite, which prevent a high permoporosity of the reservoir. In the crevasse lobes, the sandstones are laminated, fine and well sorted, arkosic, rarely with overgrowth feldspar and calcite poiquilotópica, and with a good intergranular permoporosity
Resumo:
Imaging diagnosis is a medical specialty that uses imaging techniques to perform diagnosis. In diagnostic imaging various methods are used such as direct absorption of photons - SPA and DPA, radiographic photometry, the dual-energy radiographic absorptiometry - DEXA, ultrasound, magnetic resonance imaging, computed tomography and optical densitometry in radiographic image. The dog can be considered one of the most widely used animals in the study of bone diseases and searching for a reliable diagnosis, although not an ideal model for the study of osteoporosis, because these animals tend not to develop a decrease in bone mineral density. The objective of this study was to analyze bone density in mongrel dogs from the determination of the variation of density along the radio-ulna bone and also the mean value related to gender, weight and age of individuals. The density analysis carried out showed that for this data set, there is a significant difference in the case of gender and age of the animal and may generalize according to these variables. The only significant difference was found in the weight, which increases bone mass is related to weight gain through the growth of the animal
Resumo:
The gastric dilatation- volvulus (GDV) is an acute and potentially lethal disease, characterized by increased size of the stomach associated with mesenteric rotation on its axis, which affects mainly large breed dogs and giants with deep and narrow chest. The diagnosis is made from the history, physical examination, clinical signs and radiographic evaluation. It is an emergency that requires immediate therapy and consists on protocols to treat shock, gastric decompression, surgical repositioning of the stomach, gastropexy and intensive post-operative care. Despite the significant progress in the elucidation of pathophysiological events, risk factors and treatment, there was almost no progress in determining the root causes of this disease. A significant advance was recently described in the literature on this topic is the technique of gastropexy laparoscopy. Instruct the owners of the high risk breeds is extremely important to avoid situations in which the severity of the illness make the surgical treatment impracticable and the animal’s condition irreversible
Resumo:
Computed Radiography (CR) is a term used to describe the system that electronically records a radiographic image. CR systems use receivers or IP (imaging plate) to capture the analog signals and then allow the readers to do the image processing and converted into digital information. With the increasing expansion of the CR for medical diagnostics it is necessary that these systems receive the same type of monitoring related to Quality Control and Acceptance to the conventional processing systems. The current legislation fails to specify the parameters and procedures to be tested, allowing that somehow, some equipment is not fully able to use in clinical routine. In this project we used the standard AAPM Report Number 93, which is already fully established outside the country and displays all test parameters in CR. From there were chosen three types of tests that were performed in a satisfactory sampling of IP´s. With this procedure it was possible to establish which of those IP's should be out of use, which reveals the important purpose of the study, demonstrating the need for Quality Control Testing and Acceptance in Computerized Radiography as soon as possible are included in the legislation regulator in the country
Resumo:
The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public
Resumo:
The maxillary lateral incisor has a very peculiar and internal morphology that can be influenced by the its external anatomy such as supernumerary roots and ruts deep root, which often hinders an effective endodontic treatment. Generally, this tooth have a single root with one root canal, but teeth with two to four channels can be found. The main canal can present ramifications such as accessory canals, laterals, collaterals, recorrents and apical deltas. All this factors interfere directally on endodonthics treatment. The objective of this work is a study of the internal anatomy of the maxillary lateral incisors by digital and conventional radiographics methods, comparing the results obteined by each method Six hundred upper lateral incisor were used in this study teeth of the collection of the Department of Anatomy ICT – UNESP. All the teeth were radiographed by vestibular face, using a digital radiographic unit(Dabi Atlante). After this step, all the teeth underwent by conventional radiographic technique(Kodak 2200) so that the results obtained were compared. To classify the channel system, it was adopted the classification of Pucci and Reig. All data obtained by digital technique were compared with those obtained in the conventional technique and were subjected to statistical analysis
Resumo:
Paediatric diagnostic radiology can be considered as a separate specialty and with distinct characteristics of the radiology applied in adult patients. This in reason of the variability in the anatomical structures size and bigger sensitivity of tissues. The literature present in its majority methodologies for segmentation and tissue classification in adult patients, and works on tissue quantification are rare. This work had for objective the development of a biological tissue classifier and quantifier algorithm, from histograms, and that converts the quantified average thickness of these tissues for its respective simulator materials. The results will be used in the optimization process of paediatrics images, in future works, since these patients are frequently over exposed to the radiation in the repeated attempts of if getting considered good quality radiographic images. The developed algorithm was capable to read and store the name of all the archives, in the operational system, to filter artifacs, to count and quantify each biological tissues from the histogram of the examination, to obtain the biological tissues average thicknesses and to convert this value into its respective simulator material. The results show that it is possible to distinguish bone, soft, fat and pulmonary tissues from histograms of tomographic examinations of thorax. The quantification of the constituent materials of anthropomorphic phantom made by the algorithm, compared with the data of literature shows that the biggest difference was of 21,6% for bone. However, the literature shows that variations of up to 30% in bone thickness do not influence of significant form in the radiographic image quality. The average thicknesses of biological tissues, quantified for paediatrics patients, show that one phantom can simulate patients with distinct DAP ranges, since variations... (Complete abstract click electronic access below)
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
By the early 20th century, the blood vessels could only be seen by anatomical studies. Shortly after the discovery of X-rays by Conrad Roentgen in 1895, the first experiments with radiographic imaging were performed with blood vessels. In 1905, the first experiment involving catheterization of arterial and venous system in dogs was performed and only in 1914 performed on living human patients. Parallel to these landmarks, there were advances in diagnostic imaging devices and the evolution of contrast substances was of utmost importance to the current angiography occupy a prominent role not only in terms of diagnosis, but also in the treatment of various disorders. The main objective of this review is to weave historical considerations and comparisons between the different methodologies used in angiography, because its importance; that may be in future, a veterinary diagnostic decisive test
Resumo:
Betatherapy is a special medical technique using a radioactive source of strontium-90 for the treatment of superficial lesions, especially in dermatology and ophthalmology. Strontium-90 sources emit β radiation, which possesses high ionization power, but a very short distance propagation into matter. This work presents a method of dosimetric analysis of betatherapy using strontium- 90-based instrumentation, commonly used against superficial diseases, such as keloid and pterygium, aiming the description of the dosimetry analysis procedures, which can be easily implemented on tradiotherapy services that offers the betatherapy treatment. IBF-MEDIX radiographic films (conventional films) were exposed to betatherapy applicators during different time intervals according to the activity of the source, and afterwards the optical densities (O. D.) of the radiographic images were measured using an optical densitometer MACBETH. Therefore, the parameters used to make the dosimetric analysis in betatherapy were standardized, as the exposure time depended on the geometry and size of the source, providing an efficient and fast method of dosimetric analysis of the betatherapy equipment of the services, the majority of which do not have the scientific structure to perform this study
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)