615 resultados para Aparelho respiratorio
Resumo:
Permanent teeth impaction is highly prevalent among brazilian people. Its etiology is related to local and general factors association. Permanent teeth retention compromises dental occlusion and when anterior teeth are involved, it also brings esthetics impairments which lead to psychological disturbance. Early diagnosis and adequate treatment are extremely important to solve not only occlusal problems but also psychological aspects. Orthodontic traction of impacted teeth can be conducted by using fixed or removable appliances. Although it depends on patient compliance the use of removable appliances provides an anchorage based on the teeth and the palate reducing undesirable side effects. This paper describes the case of a fourteen years old female patient whose right maxillary central incisor was adequately tractioned with a removable orthodontic appliance. Removable orthodontic devices were used at first to reposition teeth in maxillary anterior area what provided adequate space to allow the placement of the impacted incisor and after were also used to traction and position this tooth. The procedure described seemed to be effective, non expensive and a viable treatment to be performed even on the scope of public health services, extending orthodontic treatment to a higher number of patients.
Resumo:
The aim of this study was to evaluate the facial profile changes due to natural growth and induced by Herbst appliance and Bionator in the treatment of Class II, division 1 malocclusion. In order to do that, we used a sample of 90 lateral radiographs of 45 individuals in pre-pubertal stage, divided up in two experimental groups and one control. The first group, composed of 15 brazilian individuals, with initial mean age of 9.4 years, was treated with the Herbst appliance for a period of seven months. The second experimental group consisting of 15 brazilian individuals, initial mean age of 9.9 years has gone through bionator therapy for an average period of 21 months. The control group of 15 individuals, who were not treated orthodontically, comes up from the Burlington Growth Centre, University of Toronto, Canada. The intragroup comparison was performed using the Student t test and intergroup comparisons by ANOVA complemented by the Bonferroni test. The results have shown that only the group treated with the Herbst appliance presented significant changes in facial profile with improvement of its convexity and lower lip protrusion.
Resumo:
Immediate reutilization of the expanding action in a case of rapid maxillary expansion surgically assisted. The orthopedic rapid maxillary expansion (RME) and rapid maxillary expansion surgically assisted (RMESA) are conducted with the aim of giving an appropriate jaw, capable of providing a normal occlusion. In extreme cases, where there is a severe atresia, it is necessary to perform an expansion beyond that allowed by the expander, followed by another conventional device or a butterfly expander, when the atresia is in the anterior maxillary region. In this situation, there are two options: wait about 90 days to allow intermaxillary suture restructuring and perform a new RME / RMESA or proceed immediately to the expansion process. Considering the biological cost, financial and clinical time, the procedure of reusing the immediate expander action becomes the technique of choice in these cases, been the operational procedure performed simplified and in just four steps. This work will show a case report where, after accomplishing the RMESA was observed that even after changing the shape of the maxillary arch, the severity of atresia could not be corrected, especially in the anterior region, and more expansion was needed. Aiming to correct the atresia in the anterior maxilla, the technique used was to reuse the immediate expander action through the change of an intraoral screw expander for a conventional butterfly type screw expander.
Resumo:
The aim of this study was to evaluate the vertical and horizontal dentoskeletal changes induced by the Klammt Open Elastic Activator in the treatment of the Class II Division 1 malocclusion. The sample of 34 children was divided into two groups of 17 subjects each (ten girls, seven boys), matched by age and gender and with an initial mean age of 8.5 years. The data was analyzed using a Student's t-test for intragroup and intergroup comparison. The results showed that the appliance promoted dentoalveolar restriction of the maxilar growth within normal anteroposterior and vertical growth of the maxillary apical base; increment in the vertical displacement the mandibular symphysis associated with normal horizontal growth of the mandible; palatal tipping of the upper incisors; restriction of the anterior migration of the upper molars; greater eruption pattern and normal anterior displacement of the lower incisors and molars. It was concluded that Klammt appliance induce changes that are predominantly horizontal dentoalveolar in upper arch and vertical dentoalveolar in lower arch and vertical skeletal changes in the mandible.
Resumo:
Class II malocclusion features a high prevalence in Brazil, being considered as a routine in orthodontic clinics. A number of appliances are shown in the literature in order to correct Class II malocclusion with mandibular retrusion. Herbst´s fixed functional appliance, idealized by Emil Herbst (1905) and reintroduced, in the 1980´s, by Hans Pancherz is highlighted for maintaining the mandible continuously advanced, showing a shorter active treament time, an immediate esthetic impact on the facial profile, as well as requiring no patient´s commitment. Recent researches indicate the use of this appliance in individuals after pubertal growth surge. The aim of the present study is to show the orthodontics practitioner the option to use this appliance so as to treat Class II in individuals after the growth surge, obtaining satisfactory outcomes and further Class II correction.
Avaliação das dimensões e relacionamento dos arcos dentários após tratamento com Bionator de Balters
Resumo:
The deficiency of data in the literature took us to evaluate the Bionator of Balters appliance in the alterations of the dimensions and the relationship of the dental archs in children with malocclusion Class II, division 1 of Angle. The experimental group was constituted by 36 pairs cast Caucasians patients, aged between 7 years and 10 months - 11 years and 8 months, being 10 females and 8 males. The Levene´s test showed statistical evidences of likeness among the groups. Statistical analysis was preceded and showed significant alterations (p < 0,005) in the variable indicatives of maxillary first molars' distance, overjet, upper arch total length, upper arch anterior length, right molar relationship, left molar relationship, right canine relationship and left canine relationship. On the other hand, there wasn't significant alteration related to the lower arch and maxillary intercanines distance. The Balters' Bionator appliance had a favorable effect in the improvement of the correction of the malocclusion in Class II (foremost in molars and canines relationship) and transversal increase of the upper arch, mainly in the posterior area of arch.
Resumo:
This study evaluated the maxillary transversal changes caused by the rapid maxillary expansion (RME) accomplished by Hyrax appliance. Sixteen children from both genders were selected and treated, with ages between 7.7 to 10.8 years, who presented unilateral or bilateral posterior crossbite. Postero-anterior radiographs were taken at the beginning of the treatment, end and post-retention period. The treatment promoted an average opening of 8.8 mm of IMD (intermolar distance), 2.33 mm of IAD (interapex distance) and none of IID (interincisal distance). At the end of retention period, relapse was observed, with a decrease of 4.3 mm of IMD, 1.23 mm of IAD, a non-significant enlargement of IID (0,38 mm).These results confirm the significant influence of Hyrax appliance on transverse dimensions, represented by enlargement of IMD and IAD and its effectiveness to solve posterior crossbites.
Resumo:
Patients are looking for esthetic and functional changes when seeking orthodontic treatment and expect the remaining of a stable occlusion. Occlusion stability is one of the goals of the orthodontist; however, dental relationships changes in long-term can occur leading to a relapse of the treatment. Teeth and shape of arches tend to return to the original form, been the retention phase important after the appliance removal, even after several years of post-treatment. This article approaches a submission of a clinical case of Class II division 1 treated with extraction of premolars analyzing its long-term stability.
Resumo:
The apnea and hypopnea sleep obstructive syndrome is a disorder that affects part of adult population. Some characteristics can come with this syndrome that cause social problems such as snoring and excessive daytime sleepiness, associated many times with pulmonary hypertension and cardiac insufficiency. The dentist who is inserted into a multidisciplinary team is a professional highly regarded for diagnosis and treatment of sleep disorders. Among treatments recommended, therapy with intraoral appliance shows an excellent non invasive alternative, achieving satisfactory results.
Resumo:
Bite block is a functional orthodontic appliance that promotes relative intrusion or dental eruption inhibition. The purpose of this study is to present the effects of bite block on the treatment of an open bite case report.
Resumo:
A má oclusão de Classe II é originária de vários fatores etiológicos e uma das características mais comum desta má oclusão é a retrusão mandibular3, por esse motivo, os aparelhos de avanço mandibular são eleitos para o tratamento e correção desta má oclusão. Um destes aparelhos é o Herbst, que apresenta várias formas de ancoragens na sua confecção10. Tradicionalmente, as bandas eram o sistema de ancoragem mais usado, no entanto, pela alta frequência de quebras as mesmas foram substituídas por esplinte metálico12. Esse aparelho quando confeccionado de cromo cobalto pelo método da prótese parcial removível, apresenta como desvantagens a quantidade de passos laboratoriais e a possível contração do metal, podendo ocasionar a má adaptação da estrutura metálica à boca do paciente. Dessa forma, este artigo apresenta um novo método de confecção do aparelho de Herbst esplinte metálico fundido com uso da Duralay e liga níquel cromo. Esse método diminui os passos laboratoriais, proporciona maior resistência à tração e minimiza a contração da estrutura metálica, pois a resina química Duralay proporciona menor expansão do que a cera2.
Resumo:
Extraoral appliances represent an alternative for correction of Class II malocclusions. The application of external force leads to tooth movement and influence the growth of the maxillomandibular complex. This article aims to present the removable headgear as an adjuvant in the treatment of Class II division 1 in the mixed dentition.
Resumo:
The non-eruption of teeth due to highly keratinized gingival mucosa is a frequent event in the pediatric dentistry, which harms the oral aesthetics and function. A surgical excision of the involved area is indicated, exposing the non-erupted tooth. This procedure involves anesthesia and cutting instruments that may increase the fear and anxiety in young patients. The use of new technologies has avoided these instruments and has promoted more comfort to the patients. This study presents clinical cases in which gingivectomy was performed using the innovative method with an ultrasound-activated CVD tip. It was concluded that this method presented effectiveness, promoted more comfort, and less fear to the patients, making its use a viable alternative to pediatric surgery.
Resumo:
Over the last few years, new technologies have been developed to making cavity preparations, among which the diamond burs CVDentus® (CVDentus, São José dos Campos, Brazil) are outstanding. These points are produced by chemical deposition from the vapor phase, forming a single diamond stone, with greater durability than the conventional diamond burs. Coupled to the ultrasound appliance, they have several clinical applications in Dentistry with advantages over conventional rotary instruments, such as lower pressure, noise, vibration and heat, as well as reducing the need to use local anesthesia, contributing to minimize patient’s fear and anxiety. The aim of this study was to present the complete restorative dental treatment performed with this system in a child patient with a prior history of non-cooperative behavior. The use of this new technology offered the patient greater comfort, making it possible recondition the patient’s attitude to dental treatment, in addition to favoring conservative cavity preparations to be made.
Resumo:
This study assessed the surface microhardness of compound resins cured by different light sources. Methods Three micro hybrid (Vit-l-escence, Amelogen Plus, Opallis) and one nanoparticle (Filtek Z350, 3M ESPETM Dental Products, St. Paul, USA) compound resins were selected. The resins were polymerized by a halogen light unit (Ultralux, Dabi Atlante, Ribeirão Preto, Brasil) with two tips, one semi-guided made of glass and another of painted acrylic and a LED-based source (UltraLume 2, Ultradent®, South Jordan, USA). Specimens constructed from a circular aluminum matrix were photopolymerized for 40 second after they received the compound resin and stored dry for 24 hours. After this period, a Vickers surface microhardness assay was performed, measuring the top (hardness 1) and base (hardness 2) surfaces four times each. Variance analyses were complemented by Newman-Keuls method, with significance set at 5%. Results The Opallis (FGM, Santa Catarina, Brasil) resin subjected to UltraLume 2 (Ultradent®, South Jordan, USA) obtained the lowest mean hardness values for the top surface. The Vit-l-escence (Ultradent®, South Jordan, USA) compound cured by Led UltraLume 2 (Ultradent®, South Jordan, USA) and by Ultralux PCP (Dabi Atlante, Ribeirão Preto, Brasil) halogen light obtained the highest mean hardness, followed by the Filtek Z350 (3M ESPETM Dental Products, St. Paul, USA) resin subjected to UltraLume 2 (Ultradent® South Jordan, USA). The Opallis (FGM, Santa Catarina, Brasil) resin cured by LED UltraLume 2 (Ultradent®, South Jordan, USA) also obtained the lowest mean hardness for the base surface and the Vit-L-Escence (Ultradent®, South Jordan, USA) resin obtained the highest value, followed by Amelogen Plus, when cured by Ultralux (Dabi Atlante, Ribeirão Preto, Brasil) using the semi-guided tip. Conclusion The polymerization and, consequently, the microhardness achieved by the LED unit was equivalent to those achieved by conventional halogen units for three of the four composites tested.