590 resultados para Maxillofacial prostheses
Resumo:
In this article the authors clinically compare the efficacy of two different anti-inflammatory drugs - Etoricoxib (Arcoxia®) and Diclofenac (Olfen®) – in the control of postoperative pain resulting from the surgical removal of impacted lower third molars. Fifteen patients requiring the extraction of bilaterally impacted lower third molars were selected at the Department of Oral and Maxillofacial Surgery at the Araraquara School of Dentistry – UNESP. The drugs were randomly administered during the first and second surgical procedures. Pain was evaluated by means of a visual analogic scale for 72 hours following the surgical procedure. After statistical analysis of the results, the authors concluded that there were no significant differences in terms of postopoerative pain control between the two drugs studied.
Resumo:
This study evaluated postoperative results of 8 cases of frontal sinus fractures treated by frontal sinus obliteration with autogenous bone from the anterior iliac crest. Patients and methods: The medical charts of patients sequentially treated for frontal sinus fractures by obliteration with autogenous cancellous iliac crest bone in the Oral and Maxillofacial Surgery Division of this institution were reviewed. From those, eight had complete records and adequately described long-term follow-up. All were operated by the same surgical team. Those patients were recalled and independently evaluated by 2 examiners. Radiographs and/or CT scans were available for this evaluation. Associated fractures and complications were noted. The average postoperative follow-up was 7 years, ranging from 3 to 16 years. The main complication was infection. Four patients (50%) had uneventful long-term follow-ups and four (50%) experienced complications requiring reoperation. Based on the studied sample studied the authors conclude that the obliteration with autogenous bone presented a high percentage of complications in this series.
Resumo:
This study evaluated postoperative results of 8 cases of frontal sinus fractures treated by frontal sinus obliteration with autogenous bone from the anterior iliac crest.
Resumo:
The incidence of fractures of the atrophic edentulous mandible is still low, even with the increasing life expectancy. The reduced blood supply of the sclerotic bone, the diminished contact area between bone fragments and the patient’s systemic condition makes the treatment of those fractures a challenge for any professional. Treatment of atrophic mandibular fractures by means of miniplate osteosynthesis has not been the preferred method of fixa- tion by many authors. Yet, many surgeons have applied this type of fixation for the atrophied jaw sections. This paper reports 2 cases of fractured atrophic mandibles treated with the pencilboneplate, a monocortical 2.0 mm titanium, 8 or 10-hole hardware with reinforcement on its middle portion, highlighting important considerations of its use. The pencilboneplate appears to be a valuable option for the treatment of atrophic mandibular fractures, espe- cially by an intra-oral approach, and warrants further bio- mechanical and clinical studies.
Resumo:
Aims: This study compared fractal dimension (FD) values on mandibular trabecular bone in digital and digitized images at different spatial and contrast resolutions. Materials and Methods: 12 radiographs of dried human mandibles were obtained using custom-fabricated hybrid image receptors composed of a periapical radiographic film and a photostimulable phosphor plate (PSP). The film/ PSP sets were disassembled, and the PSPs produced images with 600 dots per inch (dpi) and 16 bits. These images were exported as tagged image file format (TIFF), 16 and 8 bits, and 600, 300 and 150 dpi. The films were processed and digitized 3 times on a flatbed scanner, producing TIFF images with 600, 300 and 150 dpi, and 8 bits. On each image, a circular region of interest was selected on the trabecular alveolar bone, away from root apices and FD was calculated by tile counting method. Two-way ANOVA and Tukey’s test were conducted to compare the mean values of FD, according to image type and spatial resolution (α = 5%). Results: Spatial resolution was directly and inversely proportional to FD mean values and standard deviation, respectively. Spatial resolution of 150 dpi yielded significant lower mean values of FD than the resolutions of 600 and 300 dpi ( P < 0.05). A nonsignificant variability was observed for the image types ( P > 0.05). The interaction between type of image and level of spatial resolution was not signi fi cant (P > 0.05). Conclusion: Under the tested, conditions, FD values of the mandibular trabecular bone assessed either by digital or digitized images did not change. Furthermore, these values were in fluenced by lower spatial resolution but not by contrast resolution.
Resumo:
Purpose: This study was designed to evaluate the correlation between computed tomography findings and data from the physical examination and the Friedman Staging System (FSS) in patients with obstructive sleep apnea (OSA). Patients and Methods: We performed a retrospective evaluation by reviewing the medical records of 33 patients (19 male and 14 female patients) with a mean body mass index of 30.38 kg/m 2 and mean age of 49.35 years. Among these patients, 14 presented with severe OSA, 7 had moderate OSA, 7 had mild OSA, and 5 were healthy. Results: The patients were divided into 2 groups according to the FSS: Group A comprised patients with FSS stage I or II, and group B comprised patients with FSS stage III. By use of the Fisher exact test, a positive relationship between the FSS stage and apnea-hypopnea index ( P = .011) and between the FSS stage and body mass index ( P = .012) was found. There was no correlation between age ( P = .55) and gender ( P = .53) with the FSS stage. The analysis of variance test comparing the upper airway volume between the 2 groups showed P =.018. Conclusions: In this sample the FSS and upper airway volume showed an inverse correlation and were useful in analyzing the mechanisms of airway collapse in patients with OSA.
Resumo:
Objective The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Patients and method Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. Results In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. Conclusion With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.
Resumo:
This work aims at contributing to increase and improve the communication between orthodontists and maxillofacial surgeons, reviewing and discussing the principles of diagnosis and orthodontic movement specific to patients with surgical indication. It describes the elective points in the conduct of the orthodontist so that their decisions could lead to an individualized and appropriate planning, striving for excellence in terms of outcomes for the surgical-orthodontic treatment of dentofacial discrepancies.
Resumo:
The Combination Syndrome represents an important pathologic condition of the masticatory system that requires a complex rehabilitation treatment. The presence of flaccid mucosa is one of the most common features due to bone resorption of the pre-maxilla caused by anterior hyperfunction of the mandibular teeth on the maxillary complete denture, where the impact of oclusal loading in this region results in movement of the maxillary prosthesis into the ridge, resulting in increased resorption of the residual ridge, internal misfit and loss of the retention of the maxillary complete denture. The presence of flaccid mucosa, in such cases, leads to problems of support and stability of the maxillary complete denture, which can be treated by surgical reduction of the thickness of the tissue or using specific techniques of fabrication of prostheses. This article describes the oral rehabilitation of a patient with the Combination Syndrome where the surgical reduction of flaccid mucosa was not performed, using a modified technique of functional impression in two steps, with the objective of generating forces and less distortion in flaccid mucosa during functional impression.
Resumo:
Introduction: the oral rehabilitation in edentulous patients using removable complete dentures is a classic treatment, easily accessible, and presenting satisfactory results. However, to succeed in this type of treatment, stability is an extremely important factor. The neutral zone technique for the production of complete dentures determines the oral cavity space for the positioning of teeth and denture base that provide a neutralization of the forces delivered by lips, cheeks, and tongue, providing better stability and retention of prostheses, which is indicated in cases with history of difficulties in adapting the conventional mandibular denture. Objective and case report: this paper aimed to describe a clinical case report of the oral rehabilitation of a patient with paraprosthetic muscles hypertonicity through removable complete dentures produced by the neutral zone technique, using condensation silicone. Final considerations: the use of condensation silicone for the development of the neutral zone technique showed to be a good alternative for the development of this clinical case, providing satisfactory stability and retention of the complete mandibular denture.
Resumo:
The use of different methods and materials should be considered during the planning of implant-supported prostheses. Complications such as fractures of the acrylic resin base, wear and fracture of teeth can occur frequently, creating the need for careful planning for each patient, which can make the selection of the type of treatment more complex. Thus, this article describes the oral rehabilitation of a completely edentulous patient with bimaxillary fixed implant-supported prosthesis, with complaints on aesthetics, loss of vertical dimension and fracture of acrylic resin teeth of the upper arch. After the restoration of vertical dimension, his dentures were replaced with new bimaxillary implant-supported fixed prostheses, ceramic and acrylic resin were used as veneering material for maxilla and mandible, respectively. At the end of the treatment, the patient received bimaxillary flat occlusal splints to protect the teeth and implants of possible parafunctional habits. The approach for the treatment allowed a quick and effective resolution, with aesthetic and functional outcomes very favorable for the patient.
Resumo:
The sagittal split ramus osteotomy (SSRO) is a surgical technique used widely to treat many congenital and acquired mandibular discrepancies. Stabilization of the osteotomy site and the potential for skeletal relapse after the procedure are still major problems. The aim of this study was to compare the mechanical stability of six methods of rigid fixation in SSRO using a biomechanical test model. Sixty polyurethane replicas of human hemimandibles were divided into six groups. In group I, the osteotomies were fixed with two four-hole titanium miniplates; in group II, with one four-hole miniplate; in group III, with one four-hole miniplate + a bicortical screw; in group IV, with a grid miniplate; in group V, with a four-hole locking miniplate; and in group VI, with a six-hole miniplate. A linear load in the premolar region was applied to the hemimandibles. The resistance forces (N) needed to displace the distal segment by 1, 3, and 5 mm were recorded and the data transmitted from the load cell to a computer. One-way analysis of variance with Tukey's post hoc test was performed to compare the means between groups. For the three displacement conditions, there was a strong tendency for the 2.0-mm plate + screw and the grid plate to have higher values.
Resumo:
Purpose: The objective of this article is to describe a method to construct an intraoralacrylic device that permits a reline material to be added to the inner surface of thepalatal plate.Materials and Methods: Fifteen 60-day-old adult female rats (Rattus NorvegicusAlbinus Wistar), weighing 150 to 250 g were used for this study and allocated to threegroups (n = 5): G1, animals wearing a heat-polymerized acrylic resin palatal plate(Lucitone 550) for 14 days; G2, animals wearing a heat-polymerized acrylic resinpalatal plate (Lucitone 550) relined with Tokuyama Rebase II for 14 days; and G3,animals maintained under the same conditions as the experimental groups, withoutwearing palatal plates for 14 days. The manipulation of the animals followed theguidelines of the Brazilian College of Animal Experimentation, under the approval ofthe animal ethics committee of the State University of Ponta Grossa. The palatal platescovered the whole palate, were fixed in the molar region with light-cured resin, andwere kept there for 14 days. The animals received a paste diet and water ad libitum.Before and after the trial period, the rats were weighed individually on a precisionscale. Statistical analysis was performed using a two-way analysis of variance (α =0.05) test for comparison of the animals’ weight (g) at time 0 and after 14 days ofusing the palatal plate.Results: No statistical differences were observed regarding the weight of the animalsamong the experimental groups in the study.Conclusions: The individual master impressions, the molar teeth coverage, and themethod of cementation with nonadhesive composite resin provided good stability forthe palatal plate showed in this study, not disturbing the eating habits and nutritionof the animals. This model seems reproducible, offering adequate histopathologicalevaluation. Differences in tissue morphology exist between the animals that used thepalatal plate and the animals that did not use this device. Use of these palatal platescould clarify how prostheses bring changes in the palatal mucosa of users.
Resumo:
The objective of this study is to report the clinical use of 2% Uncaria tomentosa gel against denture stomatitis (DS) as an alternative treatment. The patient was a 65-year-old, denture-wearing woman. At the clinical examination, her palate showed hyperplasic and erythematous mucosa indicating DS type II. DS is a chronic oral disease that affects denture wearers. It occurs as an inflammatory reaction in denture-wearing patients under maxillary prostheses. Candida albicans has been reported as the principal etiological agent. An alternative treatment, the topical application of a gel of 2% U. tomentosa three times a day for 1 week was given to the patient. After 1 week of this treatment, she had significantly reduced signs of the disease. Despite the existence of a great number of antifungal agents, treatment failure is observed frequently. Phytotherapy is becoming more popular worldwide. Currently, the most promising medicinal Amazonian herb is U. tomentosa (Willd.) DC., known as Cat's Claw. Studies of the chemical and pharmacological properties of this medicinal plant have allowed researchers to develop indications for its use. This report demonstrates the effectiveness of U. tomentosa against DS.