487 resultados para implant dentistry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A white female patient presented to the university clinic to obtain implant retained prostheses. She had an edentulous maxillary jaw and presented three teeth with poor prognosis (33, 34 and 43). The alveolar bone and the surrounding tissues were healthy. The patient did not report any relevant medical history contraindicating routine dental treatment or implant surgery, but self-reported a dental history of asymptomatic nocturnal bruxism. The treatment plan was set and two Branemark protocols supported by six implants in each arch were installed after a 6-month healing period. A soft occlusal splint was made due to the patient's history of bruxism, and the lack of its use by the patient resulted in an acrylic fracture. The prosthesis was repaired and the importance of using the occlusal splint was restated. In the 4-year follow-up no fractures were reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Backgroud: The influence of diamond-like-carbon (DLC) films on bacterial leakage through the interface between abutments and dental implants of external hexagon (EH) and internal hexagon (IH) was evaluated. Film deposition was performed by PECVD (Plasma Enhanced Chemical Vapor Deposition). Sets of implants and abutments (N=180, n=30) were divided according to the connection design and the treatment of the abutment base: (1) no treatment (control); (2) DLC film deposition, and (3) Ag-DLC film deposition. Under sterile conditions, 1 µL of Enterococcus faecalis was inoculated inside the implants, and abutments were tightened. The sets were tested for immediate external contamination, suspended in test tubes containing sterile culture broth, and followed-up for five days. Turbidity of the broth indicated bacterial leakage. At the end of the period, the abutments were removed and the internal content of the implants was collected with paper points and plated in Petri dishes. They were incubated for 24 h for bacterial viability assessment and colony-forming unit (CFU) counting. Bacterial leakage was analyzed by Chi-square and Fisher exact tests (α=5%). The percentage of bacterial leakage was 16.09% for EH implants and 80.71% for IH implants (P<0.0001). The bacterial load was higher inside these implants (P=0.000). The type of implant significantly influenced the results (P=0.000), whereas the films did not (P=0.487). We concluded that: (1) IH implants showed a higher frequency of bacterial leakage and (2) the DLC and Ag-DLC films did not significantly reduce the frequency of bacterial leakage and bacteria load inside the implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case report is an 8-year follow-up of a malpositioned single implant, which was treated with segmental osteotomy, to confirm the treatment's characteristics, indications, and advantages. Deep buccal positioning of an endosseous implant placed in the maxillary left central incisor area did not permit acceptable prosthetic rehabilitation, despite its favorable bone insertion with no significant marginal bone loss. The surgical procedure included osteotomy and block movement performed toward the lingual and cervical position, fixed with a provisional prosthesis and miniplates and mini-implants. A connective tissue graft was necessary for esthetics optimization and was performed in a second stage. Advantages including the prevention of alveolar ridge damage, the improvement of gingival contour, and the use of an already integrated implant are presented. Clinically satisfactory hard and soft tissue stability permitted us to consider segmental surgery as a reliable alternative for malpositioned osseointegrated implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients infected with HIV can present several complications related to oral health. Today, the reduction of morbidity and mortality is evidenttreatment with antiviral enhances the quality of life of patients. The increase in comfort, stability, function and improving quality of life have led these patients to seek treatment with osseointegrated implants. This study aimed to discuss, based on the literature, the rehabilitation treatment with osseointegrated implants in patients HIV positive. For this we carried out a literature review including the subject in the databases: PubMed, Cochrane, ISI Dentistry and Oral Science in the last 20 years. The issue was addressed for the first time in 1998, describing a clinical case, the patient had successful rehabilitation with osseointegrated implants. However, the literature states that the indications must be carefully analyzed (2007), since there are few prospective controlled studies. There is doubt as to the use of dental implant therapy in patients with HIV-positive, and the complications are related to the patient’s systemic condition. It is essential to understand the clinical manifestations and complications of the disease before the implant therapy. It is observed that the dental implant therapy in patients with HIV positive is a predictable treatment option, it´s need an adequate control of oral and systemic conditions, and studies with larger sample, longer follow-up and randomized studies are important for evaluating the success therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of his study was to review the current scientific literature in order to discuss the surgical, prosthetics and psychological/psychosocial aspects during the treatment planning of edentulous patients, when a total fixed prosthesis or overdenture is indicated. To identify studies to take part in this review, a search was conducted for the following databases: PubMed, Dentistry and Oral Sciences Source, Journals@Ovid, SpringerLink, Wiley Online Library, Nature (NPG), Oxford Journals. It was used as descriptors: total fixed prostheses and overdentures. Inclusion criteria were: clinical articles, clinical case reports, case series, literature reviews and systematic reviews that addressed the study and comparison of total fixed prostheses and overdentures for a surgical- prosthetic planning. Exclusion criteria were: laboratory and in vitro studies and those whose first language was not English or Portuguese. Of a total of 454 articles, after an analysis according to inclusion and exclusion criteria, 76 articles were selected. During an implantsupported prosthesis rehabilitation with dental in edentulous patients, the use of alternative procedures appear to be effective when compared to more invasive surgical techniques, and thus, the amount of dental implants possible to install associated with prosthetic issues such as lip support, smile line, quantity and quality of mucosa, phonetics, etc., will allow an appropriate treatment planning to each clinical case

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dissatisfaction of the treatment with mandibular complete dentures in edentulous patients has been a constant problem in Dentistry. Often, the absence of stability and retention, resultants of a physiologic condition and alveolar ridge resorption, bring reduction of chewing force, speech problems and social life interference. In these cases, the rehabilitation over osseointegrated implants can be an effective and safe alternative of treatment. When it is not possible to put implants in appropriate number and disposition, it is necessary to make a simple and low costing prosthetic planning, which makes resurge the overdentures. Various implant supported attachment systems for overdentures have been developed in the dental market. Thus, intending to facilitate the professional choice, this study review the literature about attachment systems O’ring and bar- clip in its following aspect: retention level, stress distribution, hygiene complications and patient satisfaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Morse Taper implant system, developed from its introduction in engineering, has become increasingly effective for use in dentistry. However, other systems, main external hexagon type, have been used more frequently today. Current studies have been reported the positive features of the Morse taper system and even emphasized as ideal within the systems used in implantology. Unfortunately, some professional duty by not knowing this system, or even prefer hexagon type system by decreased cost of components, have refused to use it. Thus, this study was aimed to perform a brief review of the Morse taper system, emphasizing its main points of interest in dentistry, in an attempt to familiarize the professionals to at least learn more about this system that has the prospect to become the leading system implants used in dentistry in the coming years. It is concluded that this system of dental implants is favorable showing predictability and success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The maintenance of Implant-supported Prosthesis is essential to the success of dental implants. Therefore, the aim of the study was to conduct a review the literature addressing maintenance Implant-Supported Prosthesis in order to guide planning for the longevity of oral rehabilitation. We conducted a detailed search strategy for the Pubmed / Medline Dentistry and Oral Science, used as descriptors: “Oral Hygiene“ and “Dental Implant until July, 2013. The results were grouped together in topics (Clinical Exam and Oral Hygiene) and discussed. Conclusion: A regular maintenance program for oral patient implantprosthesis is essential to the longevity of the treatment. Different methods and devices are effective for cleansing. However one orientation (in writing) must be offered to patients, since inadequate cleaning can create regions of abrasion on the surfaces of abutments and dental implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The identification and treatment of peri-implant infections are an essential stage in the maintenance of dental implants, reflecting the longevity of rehabilitation. Therefore, the aim of the study was to conduct a literature review addressing peri-implantitis in dental implants in order to guide planning for the longevity of oral rehabilitation. It was conducted a detailed search strategy by the PubMed / Medline Dentistry and Oral Science, it was used as descriptors: “peri-implantitis” and “Dental Implant”, until July 2013. From 566 articles, after a review, according to the inclusion criteria, 34 articles were selected. The results were grouped together in topics (concept, etiology, diagnosis, surgical and nonsurgical, and aspects of oral rehabilitation) for further discussion and conclusions. Conclusions: The accumulation of plaque has been associated with a higher propensity to peri-implantitis. There is a higher incidence of the peri-implantitis disease among patients with previous history of periodontal disease. The local administration of antibiotics and association with mouthwashes / topical use are indicated as suitable for the treatment of moderate peri-implantitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The short dental implants represent an option of previsible treatment, its main indication lives in the possibility of avoiding techniques surgical invasive. The literature in the display that the geometry of the implants is of vital importance, combined with wide diameters and surface treatment, mainly when the bone quality is unfavorable. The mechanical resistance can be enlarged, increasing the number of implants and being used the spliting among them. A rigorous protocol prosthodontist should be following with intention of to avoid oblique loads and to control habits parafuncionais. We aimed at to discuss, through a wide bibliographical revision the short dental implants, their characteristics and indications, giving emphasis to the aspects biomechanic of the same ones. Material and Method: The bases given: Pubmed, ISI and Dentistry Oral Science from 1990 to 2009, were consulted to identify researches related to the length of the dental implants, with emphasis to the considered short and the biomechanics related to the same ones. They were located 568 articles, being selected 69 that gathered the inclusion criteria. Result: Among these 69 selected, 26 articles agreed the evidence level. Conclusion: Inside of the limits of appraised data, it can be concluded that the short implants represent a good treatment alternative, especially for cases with reduced bone bed. However a rigorous indication protocol and use should be followed for warranty of the success of the treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rehabilitation of edentulous patients has been a challenge for professionals since the primary concepts and fundaments of occlusal rehabilitation. However, this philosophy has been improved by implant-supported fixed dentures that represent a predictable clinical modality on modern dentistry. Nevertheless, considering that the traditional protocol requires a long period for bone healing and definitive rehabilitation, immediate loading of implants has been advantageous for functional and esthetic rehabilitation of patients in a reduced period. The aim of this study is to discuss the biomechanical and functional fundaments of occlusion for implant-supported fixed dentures with mediate and immediate loading to provide clinical evidences for longevity of this treat ment modality based on the current literature. According to this, some prerequisites as proper bone quality, excellent primary stability, sufficient number of implants, rigid splinting, and control and mastering of biomechanical fundamentals of static and dynamic occlusion are mandatory for treatment predictability and longevity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to assess the contributions of some prosthetic parameters such as crown-to-implant (C/I) ratio, retention system, restorative material, and occlusal loading on stress concentrations within a single posterior crown supported by a short implant. Materials and Methods: Computer-aided design software was used to create 32 finite element models of an atrophic posterior partially edentulous mandible with a single external-hexagon implant (5 mm wide × 7 mm long) in the first molar region. Finite element analysis software with a convergence analysis of 5% to mesh refinement was used to evaluate the effects of C/I ratio (1:1; 1.5:1; 2:1, or 2.5:1), prosthetic retention system (cemented or screwed), and restorative material (metal-ceramic or all ceramic). The crowns were loaded with simulated normal or traumatic occlusal forces. The maximum principal stress (σmax) for cortical and cancellous bone and von Mises stress (σvM) for the implant and abutment screw were computed and analyzed. The percent contribution of each variable to the stress concentration was calculated from the sum of squares analysis. Results: Traumatic occlusion and a high C/I ratio increased stress concentrations. The C/I ratio was responsible for 11.45% of the total stress in the cortical bone, whereas occlusal loading contributed 70.92% to the total stress in the implant. The retention system contributed 0.91% of the total stress in the cortical bone. The restorative material was responsible for only 0.09% of the total stress in the cancellous bone. Conclusion: Occlusal loading was the most important stress concentration factor in the finite element model of a single posterior crown supported by a short implant.