531 resultados para Matériais dentários


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The biocompatibility of two dentin adhesives (Scotchbond MultiPurpose- 3M and Optibond Multi-Use - Kerr) was evaluated in rats subcutaneous connective tissue implants. Polyethylene tubes filled with the adhesives were surgically implanted into the dorsal subcutaneous tissues of rats. The tubes were left implanted for periods of 14, 30, 60 and 84 days, following wich the animais were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microscopy. After 14 and 30 days the tubes were surrounded by a mild to moderate inflammatory infiltration. After 60 and 84 days microscopic examination revealed the formation of a connective tissue capsule around each tube. The microscopic examination of the biopsy specimens allowed to conclude that: a) both dentin adhesives are considered biologically acceptable when placed in contact with rats subcutaneous connective tissue; b) in the observation period of 30 days there were moderate tissue reaction to the Optibond Multi-Use -light cure- (Kerr); c) after 60 and 84 days the use of both dentine adhesives did not interfere in the healing of the surrounding connective tissue

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the mean of alveolar bone loss (%) in radiographies of patients referred to specialist for periodontal treatment. Full mouth series of periapical radiographies (paralelism technique) were used. A total of 9808 proximal surfaces in 4804 teeth of 213 patients (90 males and 123 females), mean age, 44.3 years, were assessed. The alveolar bone loss was measured in relation to root lenght expressed as an average similar to Schei 's technique (1959) without the use of ruler. The references used were the distances cement-enamel juntion (CEJ) - alveolar crest (AC) and CEJ- dental apex taken with a digimatic caliper. The results showed that the mean values of alveolar bone loss (%ABL) was 22.39%. Men showed higher mean values of %ABL than women; the %ABL increased with the age, but the difference among age groups was no statistical significant (p>0.05); the mean values of %ABL of distal surfaces was higher than mesial surfaces (p<0.01), ríght quadrants exhibited higher %ABL values than left quadrants (p<0.01); maxillary sites showed mean values of %ABL higher than mandibular sites; the highest mean values of %ABL was found in molar group, followed by incisor groups, and premolar group; the canine group exhibited lower mean values of %ABL; the differences among the groups was considered statitistically significant (p<0.01). lt was suggested the usage of this technique in the dentistry offices and radiological services for the patient 's documentation and assortment and for later comparison about alveolar bone level

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Biopatologia Bucal - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the volumetric changes due to polymerization and thermocycling on different resin-composites. Methods: Thirteen A2 Universal Dentin shade resin-composites (n = 10) from eight manufacturers were evaluated (4Seasons, Grandio, Venus, Amelogen Plus, P90, Z350, Esthet-X, Amaris, Vita-l-escence, Natural-Look, Charisma, Z250 and Opallis). The polymerization shrinkage percentage (PS) was calculated using an image measurement device (ACUVOL - Bisco Dental). Equal volumes of material, standardized by a semisphere polyurethane matrix (d = 3mm) were used and, after 5 minutes of relaxation, the baseline volume measurements were obtained with 18 J of energy dose from the LED light-curing unit. Measurements were obtained after 5 minutes and PS values calculated. Specimens were stored in a drydark environment for 24 hours and re-measured. Specimens were then thermocycled in distilled water between 5oC and 55oC for 20,000 cycles, subjected to another volume measurement at 5,000 cycle intervals. Specimens were gently dried prior to each measurement. Results: Repeated measurements were made using ANOVA (α = 0.05) showed that all resin-composite volumes were influenced by the number of cycles. Volumes at 5 minutes post-polymerization (12.47 ± 0.08) were significantly lower than those at baseline (12.80 ± 0.09). Volumes at 24 hours (12.43 ± 0.19) were insignificantly lower than those at 5 minutes postpolymerization. With regards to the impact of thermocycling, all specimens showed statistically significant increases in volume after 5,000 cycles (13.04 ± 0.22). Although statistically different from those after 5,000 cycles, there was no statistically significant difference between volumes measured at 10,000 (12.87±0.21), 15,000 (12.92±0.24), and 20,000 (12.84±0.23) cycles. Conclusion: According to the video-imaging analysis, thermocycling caused a significant expansion in resin-composites tested, the volume increase was not able to...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Recent studies have evaluated the relationship between the width of keratinized mucosa and peri-implant tissue health. Insufficiently wide keratinized tissue can be increased surgically, for example by free gingival grafting. The presence or reconstruction of keratinized tissue around the implant can facilitate restorative procedures, promote aesthetics and allow the maintenance of an oral hygiene routine without irritation or discomfort to the patient. Objective: To describe a patient who underwent free gingival graft surgery to increase the width of keratinized tissue in the region of previously implants to support a type of prosthetic protocol. Case report: A patient who had received dental implants to support a type of prosthetic protocol presented with inflamed peri-implant mucosa, but with no keratinized tissue. Free gingival tissue was obtained from the palate and grafted into the anterior maxilla. Sixty days after muco-gingival surgery, we observed that the free gingival graft favored peri-implant health and prosthetic casting. Conclusion: The free gingival graft technique is both easy to perform and effective in increasing the width of keratinized mucosa following implantation.