452 resultados para equipamento aplicador


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we propose and describe the performance of an experimental activity to address the concept of friction in High School Physics practical classes. We use a low-cost and simple construction device that enables the determination of the coefficient of static friction between two materials through three different procedures. The results were coherent, with small percentage deviation, which gives reliability to the activity and can stimulate discussions in class. The activity also allows greater contextualization of concepts that are usually discussed only theoretically, requiring a higher abstraction level of the students. This can stimulate discussions and greater interaction between teacher and students.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atualmente a implantação de qualquer planta industrial que possa gerar impacto ambiental, ou até mesmo adequação de equipamentos já instalados para a não geração de poluentes ou geração dentro de limites adequados, passa cada vez mais por fiscalização rigorosa dos órgãos ambientais. A ventilação industrial tem sido e continua sendo a principal medida de controle efetiva para ambientes de trabalho que contenham dispersão de efluentes gasosos e material particulado de natureza prejudiciais, e baseado neste fato de relevância inegável é que se fundamenta este estudo. Um sistema de tratamento de gases com enfoque em ventilação local exaustora engloba vários equipamentos, e dentre eles o filtro de mangas é considerado um dos principais, pois sua função é a de efetuar a filtração dos gases proporcionando emissões dentro das tolerâncias dos órgãos ambientais, refletindo desta forma o objeto principal deste estudo de caso, a eficiência do equipamento. Especificamente neste estudo apresentam-se dados de eficiência do filtro de mangas em questão, componente de um sistema de desempoeiramento de uma caldeira de queima de resíduos sólidos. Foram utilizados dados coletados em campo em dois pontos do circuito do sistema, entrada do filtro de mangas e descarga de gases limpos, além de análise do elemento filtrante. As coletas e análises foram realizadas de acordo com as normas para a correta aferição dos dados gerados. Os resultados permitiram observar patamares de eficiência de filtração para os resíduos gerados na queima, demonstrando os cuidados a serem tomados no dimensionamento do equipamento para esta aplicação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper aimed to study the treatability of rainwater using natural coagulant tannin based. Assays were performed in laboratory scale and aimed to study the conditions most suitable for dosage and for pH of coagulation. Preliminary tests indicated that tannin concentration of 3% (m/m) prepared from the commercial solution presented the best set of results (84.3% of removal for apparent color and 82.51% for turbidity) compared to ferric chloride (66.25% of removal for apparent color and 67.82% for turbidity) and starch (73.68% of removal for apparent color and 67.19% for turbidity). The coagulation diagrams indicate that the best region for dosage ranges from 15 mg/L to about 37.5 mg/L and for pH ranging from about 6.5 to 7.5. The results indicate that the tannin based natural coagulant may be an alternative to conventional coagulants for rainwater treatment seeking non potable uses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we investigate the social interaction established between monitors and student-visitors to a science museum in terms of knowledge mobilized by the explanation about principle operating of Van De Graff Generator. Our research was conducted at a university public that maintains a Center of Sciences and the data were collected through recording video and audio of the dialogues established around a demonstration experiment. Data analysis is established around the conceptual correctness of the explanations made by the monitors. We also conducted a structured interview from a single question: what is the main difficulty faced in planning and conducting his presentation at the Science Center? The results show that the monitors were not able to exceed the process description of the operation of the experimental equipment, not being able to establish an interaction that fosters discussions of scientific concepts with visitors. Our research also found that, although the university maintained a Sciences Center, not there is a link between teacher training and activities in non-formal settings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Produção Vegetal) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho consiste na requalificação de área uma central da cidade de Andradina-SP, focando nas relações com o patrimônio cultural e a interação entre arte e arquitetura. Assim,busca-se explorar as potencialidades da antiga estação ferroviária de forma que o uso do Centro Cultural seja reinserido no cotidiano da população a partir de uma proposta que motive a arte e a cultura local. O projeto de um equipamento de apoio ao Centro Cultural da cidade e a concepção de um parque urbano que englobe todo o contexto abordado surgem como solução de ocupação de um vazio central

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The sunflower oleaginous is the fourth of recognized importance in the oil production and few studies related to agricultural operations adopted for this crop. The objective of the present work was to study the performance of agricultural machines in the conventional tillage and reduced in the plantation of the sunflower crop. The experiment was installed at the Experimental Farm of Lageado, belonging to the Faculty of Agricultural Sciences of UNESP, located in Botucatu-SP. It consisted of two types of tillage (conventional tillage-CC and reduced tillage-CR), with experimental design in randomized blocks and four replications. The treatment CC promoted less coverage of the soil surface protected with waste when compared to CR treatment. The chisel plow was the tillage of equipment that required the tractor higher average traction force, average power traction and slippage, consequently, promoted lower average speed of work. The theoretical field capacity and area of land involved in the treatment CR were superior when compared to treatment CC, thereby lower consumption of fuel per hour worked was lower in CR treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Forage sorghum can be grown in areas and environmental conditions dry and warm, where the productivity of other forage plants can often be uneconomical. The soil disturbance can be made only on the lines of planting (direct seeding) or entirely from the area for seeding (conventional tillage), as plowing, harrowing, subsoiling and chiseling (minimum tillage). The displacement speed ideal for planting is one in which the groove is opened and closed without removing the over-ground, allowing the distribution of seed spacing and depth constant. The experiment was conducted in a soil classified as Typic Oxisol at Lageado Experimental Farm, Faculty of Agronomic Sciences, UNESP, Botucatu campus. This study aimed to evaluate the response of sorghum in four forward speeds (3, 5, 6 and 9 km h-1) and four systems of soil management: SD (direct seeding), GP (harrow + sowing), LPG (disc harrow and two light disking + sowing) and CR (scarification and seeding). Data was subjected to analysis of variance in a factorial 4 x 4 and a randomized block design with split plots. The following parameters were determined: average speed, average strength of the drawbar, the average power drawbar, theoretical field capacity of the tractor-equipment, fuel consumption per hour. For the conditions under which the experiment was conducted, it was concluded that the hourly fuel consumption was not influenced by tillage systems and was inversely proportional to the increase of speed work, and that the change of speed in the sowing operation did not provide additional the values of average traction force on the bar of the tractor-planter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of alternative energy systems in the current days is an urgent necessity due to the problems that the planet is facing as the heating and loss of ozone layer. The scarcity of conventional energy is another problem that must be solved for the future of humanity. It must be considered that the people are inhabiting places moved away not always with available energy. The application of technologies as automation and control can help us to solve this problem. Therefore, this work aimed at apply an equipment of industrial usage, the Programmable Logical Controller, PLC, in alternative energies systems, as eolic generation and fotovoltaic generation used for water pumping, aiming the automatic control and the efficiency in the places where it has simultaneous availability of these sources, based in criterion of priority that previously established itself between them. It was made a hydraulic and energetic evaluation of the energy system, eolic and fotovoltaic, used in the automatic control system of pumping, in the place of accomplishment of the experiment, according to previously established physical conditions. The results have shown that the control system using the PLC is practicable and has trustworthiness. The program developed can be adapted for the use with several power plants in a specific application place. The fotovoltaic system of pumping, using a polycrystalline of 70 Watts connected to a pump Shurflo 8000, showed to be efficient with significant flows in almost all the months. The eolic system of pumping, using an eolic generator of 400 Watts assembled in place of experiment, did not demonstrate energetic capacity for use in this specific type of application.