590 resultados para Maxillofacial prostheses
Resumo:
Autogenous bone is still considered the gold standard, and the applicability of autogenous bone grafts is well established. However, the possibility of second harvesting from the same donor region remains unclear. The aim of this study was to perform a prospective evaluation of hard tissue deposition in the mandibular ramus after bone block harvesting using cone beam computed tomography (CBCT). Twenty-two patients with indications for augmentation procedures using autogenous bone from the mandibular ramus were selected. Three CBCT scans were performed with a tomographic guide before bone harvesting (T1) and at 14 days (T2) and 6 months (T3) after the surgical procedures. Measurements were obtained in 2D (area, mm(2)) and 3D (volume, mm(3)), and were subsequently compared. In the 2D analysis, the mean bone formation rate was 56%, while for the 3D analysis the mean rate was 9.7%. Despite this difference, there was a significant correlation between area and volume measurements. Our findings demonstrated the presence of hard tissue in the mandibular ramus at 6 months after bone harvesting, which suggests that it would be possible to reuse the same region for a second block harvesting. However, the second bone harvesting would involve less bone for transplantation when compared to the first bone harvesting.
Resumo:
The aim of this retrospective study was to investigate the amount of skeletal and dental expansion in patients submitted to surgically assisted rapid palatal expansion (SARPE). The sample consisted of 21 patients (14 female and seven male) with a mean age of 25.4 years (range 17.4-41.8 years). Postero-anterior (PA) cephalograms were taken pre-expansion (T1), immediately after expansion (T2), and at post-expansion retention of 120 days (T3). SARPE promoted significant transverse skeletal changes, which were maintained from T2 to T3. Dentoalveolar expansion and dental tipping were also observed in the region of the first molars and first premolars; however the net effect at the first molars was significantly less than that at the first premolars. No statistically significant effect on the width of the nasal cavity was observed. The findings indicate that peculiarities inherent to dental effects may influence the clinical options for SARPE. Skeletal expansions with SARPE were significant and stable. Dental changes were different between molars and premolars. The transverse changes after SARPE should be observed for future procedures related to the retention and the completion of orthodontic treatment.
Resumo:
Osteochondroma is a hamartomatous proliferation of cartilaginous tissue, which is the most common benign tumor of the long bones, but is relatively rare in the maxillofacial region. Most cases of mandibular condylar osteochondroma manifest with facial asymmetry or malocclusion with limited temporomandibular joint movements. Several approaches for management of this lesion have been proposed, as conservative condylectomy technique. This procedure has been suggested a valid approach to minimize facial asymmetry, contributing to the recovery of occlusion associated with no local tumor recurrence, and without condylar reconstruction procedure. Therefore, this article aims to describe a clinical report of a true osteochondroma of the mandibular condyle in a 35-year-old patient who was successfully treated using conservative condylectomy procedure.
Resumo:
Purpose: This study evaluated and compared bone heating, drill deformation, and drill roughness after several implant osteotomies in the guided surgery technique and the classic drilling procedure. Materials and Methods: The tibias of 20 rabbits were used. The animals were divided into a guided surgery group (GG) and a control group (CG); subgroups were then designated (G0, G1, G2, G3, and G4, corresponding to drills used 0, 10, 20, 30 and 40 times, respectively). Each animal received 10 sequential osteotomies (5 in each tibia) with each technique. Thermal changes were quantified, drill roughness was measured, and the drills were subjected to scanning electron microscopy. Results: Bone temperature generated by drilling was significantly higher in the GG than in the CG. Drill deformation in the GG and CG increased with drill use, and in the CG a significant difference between GO and groups G3 and G4 was observed. In the GG, a significant difference between GO and all other groups was found. For GG versus CG, a significant difference was found in the 40th osteotomy. Drill roughness in both groups was progressive in accordance with increased use, but there was no statistically significant difference between subgroups or between GG and CG overall. Conclusion: During preparation of implant osteotomies, the guided surgery technique generated a higher bone temperature and deformed drills more than the classic drilling procedure. The increase in tissue temperature was directly proportional to the number of times drills were used, but neither technique generated critical necrosis-inducing temperatures. Drill deformation was directly proportional to the number of times the drills were used. The roughness of the drills was directly proportional to the number of reuses in both groups but tended to be higher in the GG group.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this systematic review was to evaluate clinical studies on the follow-up survival of implants inserted in the zygomatic bone for maxillary rehabilitation. A comprehensive search of studies published from 2000 to July 2012 and listed in the PubMed/MEDLINE, Embase, and Cochrane Library databases was performed in accordance with the PRISMA statement. Relevant studies were selected according to predetermined inclusion and exclusion criteria. The initial database search yielded 751 titles. After filtering, 313 abstracts were selected, culminating in 42 full text articles. Application of eligibility criteria led to the elimination of 17 articles. Hence 25 full-text articles were considered clinically relevant and were included. Calculations of the interval survival rates and cumulative survival rates of implants could be carried out on the data extracted from the final list of included studies for the different time intervals. These studies reported the insertion of a total of 1541 zygomatic implants and 33 implant failures. Failure generally occurred during the first year interval and was related to clinical complications, such as recurrent acute and chronic sinusitis. After a 36-month follow-up, the survival rate was 97.86%. Additional studies with longer follow-up periods, including the number of zygomatic implants inserted and details of the variations in the surgical techniques used and the impact of the maxillary morphology are still required.
Resumo:
Because the biomechanical behavior of dental implants is different from that of natural tooth, clinical problems may occur. The mechanism of stress distribution and load transfer to the implant/bone interface is a critical issue affecting the success rate of implants. Therefore, the aim of this study was to conduct a brief literature review of the available stress analysis methods to study implant-supported prosthesis loading and to discuss their contributions in the biomechanical evaluation of oral rehabilitation with implants. Several studies have used experimental, analytical, and computational models by means of finite element models (FEM), photoelasticity, strain gauges and associations of these methods to evaluate the biomechanical behavior of dental implants. The FEM has been used to evaluate new components, configurations, materials, and shapes of implants. The greatest advantage of the photoelastic method is the ability to visualize the stresses in complex structures, such as oral structures, and to observe the stress patterns in the whole model, allowing the researcher to localize and quantify the stress magnitude. Strain gauges can be used to assess in vivo and in vitro stress in prostheses, implants, and teeth. Some authors use the strain gauge technique with photoelasticity or FEM techniques. These methodologies can be widely applied in dentistry, mainly in the research field. Therefore, they can guide further research and clinical studies by predicting some disadvantages and streamlining clinical time.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To evaluate and compare the reliability of implant-supported single crowns cemented onto abutments retained with coated (C) or noncoated (NC) screws and onto platform-switched abutments with coated screws. Materials and Methods: Fifty-four implants (DT Implant 4-mm Standard Platform, Intra-Lock International) were divided into three groups (n = 18 each) as follows: matching-platform abutments secured with noncoated abutment screws (MNC); matching-platform abutments tightened with coated abutment screws (MC); and switched-platform abutments secured with coated abutment screws (SC). Screws were characterized by scanning electron microscopy and x-ray photoelectron spectroscopy (XPS). The specimens were subjected to step-stress accelerated life testing. Use-level probability Weibull curves and reliability for 100,000 cycles at 200 N and 300 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used for fractographic analysis. Results: Scanning electron microscopy revealed differences in surface texture; noncoated screws presented the typical machining grooves texture, whereas coated screws presented a plastically deformed surface layer. XPS revealed the same base components for both screws, with the exception of higher degrees of silicon in the SiO2 form for the coated samples. For 100,000 cycles at 300 N, reliability values were 0.06 (0.01 to 0.16), 0.25 (0.09 to 0.45), and 0.25 (0.08 to 0.45), for MNC, MC, and SC, respectively. The most common failure mechanism for MNC was fracture of the abutment screw, followed by bending, or its fracture, along with fracture of the abutment or implant. Coated abutment screws most commonly fractured along with the abutment, irrespective of abutment type. Conclusion: Reliability was higher for both groups with the coated screw than with the uncoated screw. Failure modes differed between coated and uncoated groups.
Resumo:
Purpose: The aim of this prospective study was to objectively evaluate inferior alveolar nerve (IAN) sensory disturbances in patients who underwent sagittal split ramus osteotomy (SSRO) by comparing 1 side treated with a reciprocating saw with the other side treated with a piezosurgery device.Materials and Methods: Clinical evaluation of IAN sensory disturbance was undertaken preoperatively and at 1 week, 4 weeks, 2 months, and 6 months postoperatively in 20 patients who underwent SSROat the Division of Oral and Maxillofacial Surgery, Araraquara Dental School, Sao Paulo State University. The 20 patients were examined at all periods for IAN functionality by Semmes-Weinstein testing; neither the patients nor the examiner knew which side was treated using piezosurgery or a reciprocating saw.Results: The mean age of the patients was 28.4 years (range, 20 to 48 yr). Before surgery, no patient had impaired function of the IAN in any of the 8 zones in the mental and inferior lip areas. All patients reported feeling the first monofilament at the time of the preoperative test. Seven days postoperatively, all patients reported some kind of altered sensitivity in at least 1 zone evaluated.Conclusions: The results of this study suggest there was no statistically significant difference in the sensitivity of the labiomental area regarding the instrument used to perform the osteotomy. Future studies will focus on enlarging the sample and evaluating the results. (C) 2014 American Association of Oral and Maxillofacial Surgeons
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Aims: To evaluate the severity of temporomandibular disorders (TMD) of women in the municipality of Araraquara (Brazil) as well as the contribution of the perception of oral health, mandibular functional limitation, and sociodemographic variables on the severity of TMD. Methods: The participants were interviewed by telephone. Information regarding age, marital status, economic level, education, and use and type of dental prostheses was surveyed. To evaluate TMD severity, mandibular functional limitation and perception of oral health, Fonseca's Anamnesic Index (IAF), the Mandibular Function Impairment Questionnaire (MFIQ), and the General Oral Health Assessment Index (GOHAI) were used. To evaluate the contribution of these variables on TMD severity, a structural equation model (SEM) was fitted to the data and assessed by usual goodness-of-fit indices. Results: A total of 701 women with a mean age of 44.36 years (SD = 16.31) participated. According to the IAF, 59.6% (95% confidence interval = 56.00%-63.2%) of the women were classified as having TMD, of which 63.9% presented light, 26.8% moderate, and 9.3% severe TMD. Mandibular functional limitation was low in 91.0% of the women, moderate in 7.1%, and severe in 1.9%. Goodness-of-fit for the structural model was adequate. The predictors explained 43% of the variation in the TMD severity, with significant contributions of the variables dental prostheses (beta = -.008; P = .006), perception of oral health (beta = -.43; P < .001), and mandibular functional limitation (beta = .014; P = 014). Conclusion: The severity of TMD among Brazilian women was greater in non-users of dental prostheses and was also associated with greater mandibular functional limitation and poor perception of oral health.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)