510 resultados para Implantes
Resumo:
In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Ciência Odontólogica - FOA
Resumo:
In horses less than one year of age fractures of the third metacarpal bone (McIII) or metatarsal bone III (MtIII) are mainly attributed to trauma. Open reduction and internal fixation are the most common treatment method. A Quarter Horse filly with three months of age, which weighed 150kg presented a diaphyseal multifragmentar wedge fracture of right MtIII which was treated with transcortical pins and cast, associated with intralesional application of platelet rich plasma (PRP). After two years of surgery, the animal initiated a training program for racing, and six months later, the patient ran its first official match. The choice of therapeutic methods for treating fractures in horses should be one that provides an earlier repair and minor possibility of complications. Thus, the therapy association which was adopted was considered favorable, since allowed full reestablishment of locomotion of the patient and made possible its return to race.
Resumo:
The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 weeks after surgery and fragments of the tibiae containing the implants were submitted to histological and histomorphometric analyses to evaluate new bone formation at the implant-bone interface. Means (%) of bone neoformation obtained in the histomorphometric analysis were compared by Student's t-test for paired samples at 5% significance level.. The results of the histological analysis showed that osseointegration occurred for both types of implants with similar quality of bone tissue. The histomorphometric analysis revealed means of new bone formation at implant-bone interface of 79.69 ± 1.00% and 65.05 ± 1.23% for the porous- and rough-surface implants, respectively. Statistically significant difference was observed between the two types of implants with respect to the amount new bone formation (p<0.05). In conclusion, the porous-surface implants contributed to the osseointegration because they provide a larger contact area at implant-bone interface.
Resumo:
O presente trabalho buscou relacionar as novas mídias e o corpo contemporâneo juntamente com a tecnologia, isso foi desenvolvido através de uma pesquisa bibliográfica e descritiva. Foram usados buscadores eletrônicos para a consulta dos produtos científicos e acadêmicos, além dos itens convencionais de pesquisa, tais como, dissertações, teses e afins. Depois de feita toda a revisão com o material adequado e apoiada na literatura atual, consegui-se concluir que o corpo contemporâneo quando relacionado com as novas mídias atravessa não só o processo de transformação usual, mas o que vale ser destacado é a velocidade das mutações corporais que estes novos meios de comunicação exercem sobre os corpos atuais. Quando o foco passa para o corpo tecnológico, temos que este corpo é representado por uma espécie de maquina humana, que através de seus implantes e principalmente da biocompatibilidade da medicina se torna realidade na vida cotidiana e passa a despertar cada vez mais a atenção dos estudiosos do tema, outro ponto de destaque foi as duvidas e inquietações que as temáticas trouxeram ao mesmo tempo em que estas podem servir como desafio e impulsionar novos trabalhos nessa área
Resumo:
Pós-graduação em Biologia Geral e Aplicada - IBB
Resumo:
The biocompatibility of two dentin adhesives (Scotchbond MultiPurpose- 3M and Optibond Multi-Use - Kerr) was evaluated in rats subcutaneous connective tissue implants. Polyethylene tubes filled with the adhesives were surgically implanted into the dorsal subcutaneous tissues of rats. The tubes were left implanted for periods of 14, 30, 60 and 84 days, following wich the animais were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microscopy. After 14 and 30 days the tubes were surrounded by a mild to moderate inflammatory infiltration. After 60 and 84 days microscopic examination revealed the formation of a connective tissue capsule around each tube. The microscopic examination of the biopsy specimens allowed to conclude that: a) both dentin adhesives are considered biologically acceptable when placed in contact with rats subcutaneous connective tissue; b) in the observation period of 30 days there were moderate tissue reaction to the Optibond Multi-Use -light cure- (Kerr); c) after 60 and 84 days the use of both dentine adhesives did not interfere in the healing of the surrounding connective tissue
Resumo:
OBJETIVO: Avaliar experimentalmente a biocompatibilidade de cones de biovidro e biovitrocerâmico em cavidades evisceradas de coelhos. MÉTODOS: Foram utilizados 45 coelhos albinos submetidos à cirurgia de evisceração do olho direito, seguida da inclusão de cones de biovidro e dois tipos de biovitrocerâmicos (chamados de FI e FII) na cavidade escleral. Os animais foram sacrificados em três momentos (7, 90 e 180 dias). Os parâmetros avaliados foram: peso, exame clínico diário, exames bioquímicos, avaliação histológica, exame morfométrico. RESULTADOS: Os animais mantiveram-se saudáveis durante o experimento, não tendo ocorrido extrusão do implante em nenhum animal. O exame morfológico mostrou que houve a formação de pseudocápsula ao redor dos cones, com superioridade dos cones de biovidro e biovitrocerâmico FI, os quais apresentaram menor reação inflamatória e menor formação da pseudocápsula ao redor dos cones que os demais. A reação inflamatória foi mais intensa após 7 dias da colocação dos cones, diminuindo em direção aos 180 dias, sendo menos intensa nos coelhos que receberam cones de biovidro. CONCLUSÃO: Os cones de biovidro e biovitrocerâmico FI e FII podem ser úteis para a reparação da cavidade anoftálmica, com melhor resposta quando se usa cones de biovidro e de biovitrocerâmico FI.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Introduction: Recent studies have evaluated the relationship between the width of keratinized mucosa and peri-implant tissue health. Insufficiently wide keratinized tissue can be increased surgically, for example by free gingival grafting. The presence or reconstruction of keratinized tissue around the implant can facilitate restorative procedures, promote aesthetics and allow the maintenance of an oral hygiene routine without irritation or discomfort to the patient. Objective: To describe a patient who underwent free gingival graft surgery to increase the width of keratinized tissue in the region of previously implants to support a type of prosthetic protocol. Case report: A patient who had received dental implants to support a type of prosthetic protocol presented with inflamed peri-implant mucosa, but with no keratinized tissue. Free gingival tissue was obtained from the palate and grafted into the anterior maxilla. Sixty days after muco-gingival surgery, we observed that the free gingival graft favored peri-implant health and prosthetic casting. Conclusion: The free gingival graft technique is both easy to perform and effective in increasing the width of keratinized mucosa following implantation.
Resumo:
For oral rehabilitation with implant-supported prostheses, there are required procedures to create the bone volume needed for installation of the implants. Thus, bone grafts from intraoral or extraoral donor sites represent a very favorable opportunity. This study aimed to review the literature on the subject, seeking to discuss parameters for the indications, advantages and complications of techniques for autogenous bone grafts.