224 resultados para vertical flat plate
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate the effect of warm-up on agility (AG) and on vertical jump (VJ) tests in youth soccer players. Sixteen players performed the AG and VJ tests without warm-up (NW) and with warm-up (WW) randomly, within two weeks, at least 48 h interval, during season. The warm-up was performed only a light running during 10 min. The paired t-test identified significant difference (p <0,05) between the NW and WW conditions in the tests of SR and CJ (9,14 +/- 0,28 vs 8,94 +/- 0,30 s e 51,4 +/- 4,2 vs 54,5 +/- 6,4 cm, respectively). The warm-up performed on light intensity running was effective to improve the AG and VJ tests performance in youth soccer players.
Resumo:
Human motion seems to be guided by some optimal principles. In general, it is assumed that human walking is generated with minimal energy consumption. However, in the presence of disturbances during gait, there is a trade-off between stability (avoiding a fall) and energy-consumption. This work analyses the obstacle-crossing with the leading foot. It was hypothesized that energy-saving mechanisms during obstacle-crossing are modulated by the requirement to avoid a fall using the available sensory information, particularly, by vision. A total of fourteen subjects, seven with no visual impairment and seven blind, walked along a 5 meter flat pathway with an obstacle of 0.26 m height located at 3 m from the starting point. The seven subjects with normal vision crossed the obstacle successfully 30 times in two conditions: blindfolded and with normal vision. The seven blind subjects did the same 30 times. The motion of the leading limb was recorded by video at 60 Hz. There were markers placed on the subject's hip, knee, ankle, rear foot, and forefoot. The motion data were filtered with a fourth order Butterworth filter with a cut-off frequency of 4 Hz. The following variables were calculated: horizontal distance between the leading foot and the obstacle at toe-off prior to (DHPO) and after (DHOP) crossing, minimal vertical height from the foot to the obstacle (DVPO), average step velocity (VELOm). The segmental energies were also calculated and the work consumed by the leading limb during the crossing obstacle was computed for each trial. A statistical analysis repeated-measures ANOVA was conducted on these dependent variables revealing significant differences between the vision and non-vision conditions in healthy subjects. In addition, there were no significant differences between the blind and people with vision blindfolded. These results indicate that vision is crucial to determine the optimal trade-off between energy consumption and avoiding a trip during obstacle crossing.
Resumo:
In this work, we describe an experimental setup in which an electric current is used to determine the angular velocity attained by a plate rotating around a shaft in response to a torque applied for a given period. Based on this information, we show how the moment of inertia of a plate can be determined using a procedure that differs considerably from the ones most commonly used, which generally involve time measurements. Some experimental results are also presented which allow one to determine parameters such as the exponents and constant of the conventional equation of a plate's moment of inertia.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This work presents a boundary element formulation for the analysis of building floor slabs, without beams, in which columns are coupled with the plate. An alternative formulation of boundary element method is presented, which considers three nodal displacements values (w, partial derivativew/partial derivativen and partial derivativew/partial derivatives) for the nodes at the boundary of the plate. In this formulation three boundary equations are written for all nodes at the boundary and in the domain of the plate. As the nodes of the column-plate connections are also represented by three nodal values, all these structural elements can be easily coupled. It is supposed that the cross-sections of the columns remain flat after the deflection and consequently the assumption of linear variation of the stress in the plate-column contact surface is also valid. (C) 2003 Elsevier B.V. Ltd. All rights reserved.
Resumo:
The objective of this paper is to show an alternative representation in time domain of a non-transposed three-phase transmission line decomposed in its exact modes by using two transformation matrices. The first matrix is Clarke's matrix that is real, frequency independent, easily represented in computational transient programs (EMTP) and separates the line into quasi-modes a, b and zero. After that, Quasi-modes a and zero are decomposed into their exact modes by using a modal transformation matrix whose elements can be synthesized in time domain through standard curve-fitting techniques. The main advantage of this alternative representation is to reduce the processing time because a frequency dependent modal transformation matrix of a three-phase line has nine elements to be represented in time domain while a modal transformation matrix of a two-phase line has only four elements. This paper shows modal decomposition process and eigenvectors of a non-transposed three-phase line with a vertical symmetry plane whose nominal voltage is 440 kV and line length is 500 km.
Resumo:
This paper presents an experimental technique for structural health monitoring (SHM) based on Lamb waves approach in an aluminum plate using piezoelectric material as actuators and sensors. Lamb waves are a form of elastic perturbation that remains guided between two parallel free surfaces, such as the upper and lower surfaces of a plate, beam or shelf. Lamb waves are formed when the actuator excites the surface of the structure with a pulse after receiving a signal. Two PZTs were placed in the plate surface and one of them was used to send a predefined wave through the structure. Thus, the other PZT (adjacent) becomes the sensor. Using this methodology, this paper presents one case of damage detection considering the aluminum plate in the free-free-free-free boundary condition. The damage was simulated by adding additional mass on the plate. It is proposed two damage detection indexes obtained from the experimental signal, involving the Fast Fourier Transform (FFT) and the power spectral density (PSD) that were computed using the output signal. The results show the viability of the presented methodology to damage detection in smart structures
Resumo:
A presença marcante de uma prosa-poética na produção ficcional de Clarice Lispector possibilitou-nos exemplificar algumas noções centrais (tempo vertical e instante poético) na rica e sugestiva reflexão de Gaston Bachelard acerca do universo poético
Resumo:
Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.
Resumo:
Este estudo avalia os fatores maternos e fetais envolvidos na transmissão vertical do HIV-1 em 47 pares de mãe e filho. As variáveis comportamentais, demográficas e obstétricas foram obtidas mediante entrevista; os dados referentes ao parto e ao recém-nascido, dos prontuários das maternidades. Durante o terceiro trimestre de gestação foi realizada a contagem da carga viral materna e dos linfócitos T CD4+. A média de idade foi de 25 anos e 23,4% das gestantes eram primigestas, e o fator comportamental mais prevalente foi não usar preservativos. Dentre as gestantes, 48,9% tinham células CD4+ superior a 500 células/mm³ e 93,6% se enquadravam na categoria clínica A; 95,7% submeteram-se à profilaxia com zidovudina durante a gestação ou no parto, a qual foi ministrada a todos os recém-nascidos; 50,0% delas foram submetidas à cesárea eletiva. Apesar de expostas a vários fatores de risco e protetores, nenhuma criança tornou-se infectada. A transmissão vertical resulta de um desequilíbrio entre os fatores, com predomínio dos de risco sobre os protetores.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 2010
Resumo:
Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796
Resumo:
The aim of this study was to describe the treatment used in an elderly patient presenting with bruxism and dental erosion, with good gingival health and bone support, but with decreased occlusal vertical dimension (OVD). The oral rehabilitation of elderly patients presenting with bruxism in association with tooth erosion has been a great challenge for dentists. The loss of OVD, the presence of occlusal instability and the absence of an effective anterior guide due excessive dental wear, can damage stomatognathic system (SS) biology, the function and the aesthetics. In the first treatment stage, an overlay removable partial denture (ORPD) was fabricated for the immediate re-establishment of function and aesthetics. After a 2-month follow up, with the patient presenting no symptoms, a second rehabilitation stage was accomplished, with fixed and removable prostheses. Oral rehabilitation with an ORPD was able to re-establish the SS biology, but a correct diagnosis and treatment plan are essential for success. The ORPD is a non-invasive and reversible restoring modality for general dentists that allow the re-establishment of the patient's immediate aesthetics and function at low cost.