153 resultados para swimming speed


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tegtbur et al. [23] devised a new method able to estimate the intensity at maximal lactate steady state termed lactate minimum test. According to Billat et al. [7], no studies have yet been published on the affect of training on highest blood lactate concentration that can be maintained over time without continual blood lactate accumulation. Therefore, the aim of the present study was to verify the effect of soccer training on the running speed and the blood lactate concentration (BLC) at the lactate minimum test (Lac(min)). Thirteen Brazilian male professional soccer players, all members of the same team playing at National level, volunteered for this study. Measurements were carried out before (pre) and after (post) eight weeks of soccer training. The Lac(min) test was adapted to the procedures reported by Tegtbur et al. [23]. The running speed at the Lac(min) test was taken when the gradient of the line was zero. Differences in running speed and blood lactate concentration at the Lac(min) test before (pre) and after (post) the training program were evaluated by Student's paired t-test. The training program increased the running speed at the Lac(min) test (14.94 +/- 0.21 vs. 15.44 +/- 0.42* km(.)h(-1)) and the blood lactate concentration (5.11 +/- 2.31 vs. 6.93 +/- 1.33* mmol(.)L(-1)). The enhance in the blood lactate concentration may be explained by an increase in the lactate/H+ transport capacity of human skeletal muscle verified by other authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar a velocidade crítica (VC) determinada através de diferentes distâncias com o limiar anaeróbio (LAn) e as velocidades máximas mantidas em testes de 20 (V20) e 30 (V30) minutos na natação, verificando se a idade cronológica em jovens nadadores interfere nessas relações. Participaram do estudo 31 nadadores (17 meninas e 14 meninos) divididos segundo a idade cronológica em dois grupos: 10 a 12 anos e 13 a 15 anos. O LAn foi determinado como sendo a velocidade correspondente a 4mM de lactato sanguíneo. A VC1 (25/50/100m), VC2 (100/200/400m) e a VC3 (50/100/200m) foram calculadas através do coeficiente angular da reta de regressão linear entre as distâncias e seus respectivos tempos. As V20 e V30 foram determinadas através de três a seis repetições, com coletas de sangue no 10º minuto e ao final do tiro. Para o grupo de 10 a 12 anos, a VC1 (m/s) (0,98 ± 0,17) e o LAn (0,97 ± 0,12) não foram diferentes entre si, sendo maiores do que a VC2 (0,92 ± 0,16), VC3 (0,89 ± 0,18), V20 (0,92 ± 0,11) e V30 (0,90 ± 0,11). Para o grupo de 13 a 15 anos, a VC1 (m/s)(1,11 ± 0,11) foi maior do que o LAn (1,02 ± 0,07), V20 (0,99 ± 0,09), V30 (0,97 ± 0,09), VC2 (0,98 ± 0,11) e VC3 (1,00 ± 0,11). Pode-se concluir que a distância utilizada na determinação da VC interfere no valor obtido, independente da idade cronológica. A VC determinada com distâncias entre 50 e 400m pode ser utilizada na avaliação da capacidade aeróbia de crianças e adolescentes, substituindo os testes contínuos máximos com durações próximas a 20 ou 30 minutos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O principal objetivo deste estudo foi verificar o efeito do nível de performance aeróbia na relação entre os índices técnicos correspondentes à velocidade crítica (VC) e à velocidade máxima de 30 minutos (V30) em nadadores. Participaram deste estudo, 23 nadadores do gênero masculino com características antropométricas similares, divididos segundo o nível de performance aeróbia em grupo G1 (maior performance) (n = 13) e G2 (menor performance) (n = 10). Os indivíduos tinham pelo menos quatro anos de experiência no esporte e treinavam um volume semanal de 30.000 a 45.000m. A VC foi determinada através do coeficiente angular da regressão linear entre as distâncias (200 e 400m) e seus respectivos tempos. A V30 foi determinada através da máxima distância realizada em um teste de 30 minutos. Todas as variáveis foram determinadas no nado crawl. A VC foi significantemente maior do que a V30 no grupo G1 (1,30 ± 0,04 vs. 1,23 ± 0,06m.s-1) e no G2 (1,17 ± 0,08 vs. 1,07 ± 0,06m.s-1). As duas variáveis foram maiores no grupo G1. As taxas de braçada correspondentes à VC (TBVC) e à V30 (TBV30) obtidas nos grupos G1 (33,07 ± 4,34 vs. 31,38 ± 4,15 ciclos.min-1) e G2 (35,57 ± 6,52 vs. 33,54 ± 5,89 ciclos.min-1) foram similares entre si. A TBVC foi significantemente menor no grupo 1 do que no grupo 2, enquanto que a TBV30 não foi diferente entre os grupos. Os comprimentos de braçada correspondentes à VC (CBVC) e à V30 (CBV30) foram significantemente maiores no grupo G1 (2,41 ± 0,33 vs. 2,38 ± 0,30m.ciclo-1) do que no G2 (2,04 ± 0,43 vs. 1,97 ± 0,40m.ciclo-1), e similares entre si nos dois grupos. As correlações (r) entre a VC e a V30 e as variáveis técnicas correspondentes às duas velocidades foram significantes em todas as comparações (0,68 a 0,91). Portanto, a relação entre a velocidade e as variáveis técnicas correspondentes à VC e à V30 não é modificada pelo nível de performance aeróbia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thyrotoxicosis, a condition in which there is an excessive amount of circulating thyroid hormones, leads to reduced glycogen content in different tissues. In this study we analyzed the effects of aerobic swimming training on liver, heart, and skeletal muscle glycogen content in experimentally induced thyrotoxicosis. Wistar male rats were divided into euthyroid sedentary (ES, n = 12), euthyroid trained (ET, n = 11), thyrotoxic sedentary (TS, n = 12), and thyrotoxic trained (TT, n = 10) groups. Thyrotoxic groups received daily i.p. doses of T4 (sodium levothyroxine, 25 mu g/100 g body mass) through the experimental period, and trained groups swam for 1 h at 80% of the aerobic-anaerobic transition intensity, 5 days/week for 4 weeks. Heart and liver glycogen stores were similar to 30% lower in T4 treated compared with nontreated groups, but were not changed by training status. on the other hand, glycogen content in mixed fiber type gastrocnemius of TT was 1.5- to 2.3-fold greater than those in other groups, whereas no significant differences were found for the slow soleus muscle. Increased gastrocnemius but not soleus, liver, or heart glycogen indicates that in mild long-term thyrotoxicosis chronic swimming affects glycogen stores in a tissue-specific manner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by oneway ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C ( 0.56) for Group 1, 0.84 degrees C (0.55) for Group II, and 3.00 degrees C (1.34) for Group III. There were no statistically significant differences (p > 0.05) between Groups I and II, but both of them differed significantly from Group III (p < 0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of cutting initiation location and cutting speed on the bond strength between resin cement and feldspathic ceramic.Materials and Methods: Thirty-six blocks (6.4 x 6.4 x 4.8 mm) of ceramic (Vita VM7) were produced. The ceramic surfaces were etched with 10% hydrofluoric acid gel for 60 s and then silanized. Each ceramic block was placed in a silicon mold with the treated surface exposed. A resin cement (Variolink II) was injected into the mold over the treated surface and polymerized. The resin cement-ceramic blocks were divided into two groups according to experimental conditions: a) cutting initiation location - resin cement, ceramic and interface; and b) cutting speed - 10,000, 15,000, and 20,000 rpm. The blocks were sectioned to achieve non-trimmed bar specimens. The microtensile test was performed in a universal testing machine (1 mm/min). The failure modes were examined using an optical light microscope and SEM. Bond strength results were analyzed using one-way ANOVA and Tukey's test (alpha = 0.05).Results: Significant influences of cutting speed and initiation location on bond strength (p < 0.05) were observed. The highest mean was achieved for specimens cut at 15,000 rpm at the interface (15.12 +/- 5.36 MPa). The lowest means were obtained for specimens cut at the highest cutting speed in resin cement (8.50 +/- 3.27 MPa), and cut at the lowest cutting speed in ceramic (8.60 +/- 2.65MPa). All groups showed mainly mixed failure (75% to 100%).Conclusion: The cutting speed and initiation location are important factors that should be considered during specimen preparation for microtensile bond strength testing, as both may influence the bond strength results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. The use of ultrasonic tips has become an alternative for cavity preparation. However, there are concerns about this type of device, particularly with respect to intrapulpal temperatures and cavity preparation time.Purpose. The purpose of this study was to analyze pulpal temperature increases generated by an ultrasonic cavity preparation with chemical vapor deposition (CVD) tips, in comparison to preparation with a high-speed handpiece with a diamond rotary cutting instrument. The time required to complete the cavity preparation with each system was also evaluated.Material and methods. Thermocouples were positioned in the pulp chamber of 20 extracted human third molars. Slot-type cavities (3 x 3 x 2 mm) were prepared on the buccal and the lingual surfaces of each tooth. The test groups were: high-speed cavity preparation with diamond rotary cutting instruments (n = 20) and ultrasonic cavity preparation with CVD points (n = 20). During cavity preparation, the increases In pulpal temperature, and the time required for the preparation, were recorded and analyzed by Student's t test for paired samples (alpha = .05).Results. The average pulpal temperature increases were 4.3 degrees C for the high-speed preparation and 3.8 degrees C for the ultrasonic preparation, which were statistically similar (P = .052). However, significant differences were found (P < .001) for the time expended (3.3 minutes for the high-speed bur and 13.77 minutes for the ultrasound device).Conclusions. The intrapulpal temperatures produced during cavity preparation by ultrasonic tips versus high-speed bur preparation were similar. However, the use of the ultrasonic device required 4 times longer for the completion of a cavity preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By exploring the relationship between the propagation of electromagnetic waves in a gravitational field and the light propagation in a refractive medium, it is shown that, in the presence of a positive cosmological constant, the velocity of light will be smaller than its special relativity value. Then, restricting again to the domain of validity of geometrical optics, the same result is obtained in the context of wave optics. It is argued that this phenomenon and the anisotropy in the velocity of light in a gravitational field are produced by the same mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, different types of 75% Cr3C2-25% NiCr coatings were applied on a steel substrate by means of high velocity oxygen fuel spraying (HVOF), and studied using ac and dc electrochemical measurements in an aerated and unstirred 0.5 M H2SO4 solution. Structural characterization was determined before and after electrochemical tests. Differences between all sprayed systems are related to the gun transverse speed and number of deposited layers, which strongly affected the electrochemical characteristics of the coated steels. The coating obtained with a higher torch speed showed better resistance against corrosion. The electrochemical impedance results were analyzed using an equivalent circuit where porosity of the coatings and substrate oxidation were considered. (C) 2003 Elsevier Ltd. All rights reserved.