179 resultados para rotary atomizer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was aimed to evaluate the spectrum and uniformity of droplets in function of sprayers, spraying volumes and rates of chemical insecticide on the mortality of Pseudoplusia includens in laboratory. The work was carried out at UNESP, Jaboticabal, SP, Brazil. The following treatments were applied over the caterpillars: two equipments (atomizer and hydraulic nozzle); two spray volumes (17 and 50 L ha(-1) for the atomizer and 50 and 100 L ha(-1) for the hydraulic nozzle); and two dosages of the insecticide endosulfan (0.5 and 1.0 L pc ha(-1)), in fully randomized plots, in a factorial scheme 2x2x2 and 1 untreated check. The caterpillars mortality was evaluated until the 6(th) day after the application of treatments. The spectrum of the droplets was evaluated in a particle size analyzer in real time determining the diameter and spectrum of droplets sprayed through the laser beam of the analyser. It was verified that the spray volume can be reduced by 17 L ha(-1) without losses on the P. includens control. The doses of 0.5 L pc ha(-1) (recommended for Anticarsia gemmatalis) did not satisfactorily control the caterpillar soybean looper. The atomizer produces droplets of higher uniformity (SPAN: 0.52) and lower percentage of droplets susceptible to drift (3.3%) compared to hydraulic nozzle (SPAN: 1.34 e % droplets <= 100 mu m: 15.2).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A ferrugem asiática da soja, causada pelo fungo Phakopsora pachyrhizi, é considerada a principal doença da soja, e, portanto, a escolha e o uso adequado dos equipamentos de pulverização são essenciais para seu controle. O objetivo deste trabalho foi avaliar o desempenho de diferentes equipamentos de pulverização aérea para o controle curativo da ferrugem da soja, utilizando o fungicida Impact 125 SC (flutriafol) a 0,5 L p c ha-1. Os seguintes tratamentos foram avaliados: atomizador Micronair AU 5000 (10 L ha-1 com óleo e 20 L ha-1 sem óleo na calda); atomizador Stol ARD (10 e 20 L ha-1 ambos com óleo) e o sistema eletrostático Spectrum (10 L ha-1 sem óleo a 64 e 71% de umidade relativa). Utilizou-se óleo de algodão (1,0 L ha-1) acrescido de emulsificante BR 455 a 0,025 L ha-1. O ensaio foi realizado na terceira aplicação de fungicidas, quando foram analisadas quatro repetições nas áreas aplicadas e quatro testemunhas não aplicadas para cada tratamento, avaliando-se a severidade da ferrugem, os depósitos de flutriafol nas folhas de soja e o percentual de redução de ferrugem. A análise dos depósitos nas folhas mostrou que não houve diferenças significativas entre os tratamentos. Os melhores controles da ferrugem foram obtidos com os tratamentos Micronair (10 L ha-1 com óleo), Stol (20 L ha-1 com óleo) e o sistema elestrostático (10 L ha-1) com a menor umidade relativa do ar (64 %).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O efeito de diversas tecnologias de aplicação foi avaliado sobre a concentração, viabilidade e eficácia dos juvenis infectantes dos nematóides Heterorhabditis indica Poinar, Karunakar & David (IBCB-n5) e Steinernema sp. (IBCB-n6) no controle da lagarta-do-cartucho Spodoptera frugiperda Smith na cultura do milho. Para o controle da lagarta-do-cartucho no terceiro estádio em placas de Petri foram necessários 280 juvenis infectantes de Steinernema sp., enquanto que 400 juvenis infectantes de H. indica controlaram apenas 75% das lagartas. Podem-se pulverizar os entomopatógenos, sem que haja perda significativa na sua concentração e viabilidade, com equipamentos que forneçam carga elétrica à calda, ponta centrífuga e pontas hidráulicas. Entretanto, o emprego de pulverizadores com pontas que requerem elementos filtrantes com malha igual a 100 resultou em decréscimo na concentração de juvenis infectantes de H. indica e Steinernema sp., de 28% e 53%, respectivamente. Os tensoativos organosiliconado e etoxilados não afetaram a viabilidade dos juvenis infectantes de Steinernema sp. Nos experimentos de pulverização em plantas de milho (V6) com Steinernema sp., doses equivalentes a até 288 milhões de juvenis infectantes por hectare, diluídos em volume de calda de até 800 L ha-1 com 0,01 % do tensoativo etoxilado, ou nesse volume seguido de exposição a chuva artificial (lâmina de água de 6 mm), não foram suficientes para o controle de S. frugiperda em casa-de-vegetação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A tungsten carbide coating on the integrated platform of a transversely heated graphite atomizer was used as a modifier for the direct determination of Se in soil extracts by graphite furnace atomic absorption spectrometry. Diethylenetriaminepentaacetic acid (0.0050 mol L-1) plus ammonium hydrogencarbonate (1.0 mol L-1) extracted predominantly available inorganic selenate from soil. The formation of a large amount of carbonaceous residue inside the atomizer was avoided with a first pyrolysis step at 600 degreesC assisted by air during 30 s. For 20 muL of soil extracts delivered to the atomizer and calibration by matrix matching, an analytical curve (10.0-100 mug of L-1) with good linear correlation (r = 0.999) between integrated absorbance and analyte concentration was established. The characteristic mass was similar to63 pg of Se, and the lifetime of the tube was similar to750 firings. The limit of detection was 1.6 mug L-1, and the relative standard deviations (n = 12) were typically <4% for a soil extract containing 50 mug of L-1. The accuracy of the determination of Se was checked for soil samples by means of addition/recovery tests. Recovery data of Se added to four enriched soil samples varied from 80 to 90% and indicated an accurate method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a different experimental setup compared with the traditional ones, in order to determine the acceleration of gravity, which is carried out by using a fluid at a constant rotation. A computerized rotational system-by using a data acquisition system with specific software, a power amplifier and a rotary motion sensor-is employed in order to evaluate the angular velocity and g. An equation to determine g is inferred from fluid mechanics. For this purpose, the fluid's parabolic shape inside a cylindrical receptacle is considered using a rotational movement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo teve o objetivo de avaliar o comportamento de treze tipos de meios filtrantes primários desenvolvidos para uso na filtração a vácuo de lodo de caldo de cana, simulando as operações de formação e desidratação da torta em filtros contínuos de tambor rotativo a vácuo, empregados nas indústrias de açúcar e álcool do Brasil. Para tanto, foi desenvolvida uma planta-piloto anexa ao filtro de tambor rotativo a vácuo, na qual foram realizados todos os ensaios, com o objetivo de refletir a realidade das variáveis operacionais durante uma safra sucroalcooleira. Os resultados são apresentados, comparando-se as taxas de filtração, variando a pressão de formação da torta, temperatura e concentração de auxiliar filtrante, mostrando ao usuário um novo caminho para o melhoramento quantitativo e qualitativo, sem aumentar a área nominal da unidade de filtração.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work discusses on the preparation of Ni-45Ti-5Mo, Ni-40Ti-10Mo and Ni-46Ti-2Mo-2Zr (at-%) alloys by high-energy ball milling and hot pressing, which are potentially attractive for dental and medical applications. The milling process was performed in stainless steel balls (19mm diameter) and vials (225 mL) using a rotary speed of 300rpm and a ball-to-powder weight ratio of 10:1. Hot pressing under vacuum was performed in a BN-coated graphite crucible at 900 degrees C for 1 h using a load of 20 MPa. The milled and hot-pressed materials were characterized by X-ray diffraction, electron scanning microscopy, and electron dispersive spectrometry. Peaks of B2-NiTi and Ni4Ti3 were identified in XRD patterns of Ni-45Ti-5Mo, Ni-40Ti-10Mo and Ni-46Ti-2Mo-2Zr powders milled for 1h. The NiTi compound dissolved small Mo amounts lower than 4 at%, which were measured by EDS analysis. Moreover, it was identified the existence of an unknown Mo-rich phase in microstructures of the hot-pressed Ni-Ti-Mo alloys.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports on the phase transformation during the preparation of Ni-25Nb, Ni-25Ta, Ni-20Nb-5Ta and Ni-15Nb-10Ta (at-%) powders by high-energy ball milling from elemental powders. The milling process was performed in a planetary ball milling using stainless steel balls and vials, rotary speed of 300rpm, and a ball-to-powder of 10:1. To minimize contamination and spontaneous ignition the powders were handled under argon atmosphere in a glove box. The milled powders were characterized by means of X-ray diffraction techniques. Results indicated that the Ni atoms were preferentially dissolved into the Nb (and/or Ta) lattice at the initial milling times, which contributed to change the relative intensity on the diffraction peaks. After the dissolution of Nb (and/or Ta) into the Ni lattice, the Ni peaks were moved to the direction of lower diffraction angles in Ni-25Nb, Ni-25Ta, Ni-20Nb-5Ta, Ni-15Nb-10Ta powders, indicating that the mechanical alloying was achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work reports on the preparation of Al2O3-TiO2 ceramics by high-energy ball milling and sintering, varying the molar fraction in 1:1 and 3:1. The powder mixtures were processed in a planetary Fritsch P-5 ball mill using silicon nitride balls (10 mm diameter) and vials (225 mL), rotary speed of 250 rpm and a ball-to-powder weight ratio of 5:1. Samples were collected into the vial after different milling times. The milled powders were uniaxially compacted and sintered at 1300 and 1500 degrees C for 4h. The milled and sintered materials were characterized by X-ray diffraction and electron scanning microscopy (SEM). Results indicated that the intensity of Al2O3 and TiO2 peaks were reduced for longer milling times, suggesting that nanosized particles can be achieved. The densification of Al2O3-TiO2 ceramics was higher than 98% over the relative density in samples sintered at 1500 degrees C for 4h, which presented the formation of Al2TiO5.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The analysis of alcoholic beverages for the important carcinogenic contaminant ethyl carbamate is very time-consuming and expensive. Due to possible matrix interferences, sample cleanup using diatomaceous earth (Extrelut) column is required prior to gas chromatographic and mass spectrometric measurement. A limiting step in this process is the rotary evaporation of the eluate containing the analyte in organic solvents, which is currently conducted manually and requires approximately 20-30 min per sample. This paper introduces the use of a parallel evaporation device for ethyl carbamate analysis, which allows for the simultaneous evaporation of 12 samples to a specified residual volume without manual intervention. A more efficient and, less expensive analysis is therefore possible. The method validation showed no differences between the fully-automated parallel evaporation and the manual operation. The applicability was proven by analyzing authentic spirit samples from Germany, Canada and Brazil. It is interesting to note that Brazilian cachacas had a relatively high incidence for ethyl carbamate contamination (55% of all samples were above 0.15 mg/l), which may be of public health relevance and requires further evaluation.